Page 101

Read Cycle

Read Cycle Serial Commands Trigger Mode/Filter Duration <K200,trigger mode,leading edge trigger filter,trailing edge trigger filter> Serial Trigger Character <K201,serial trigger character> External Trigger State <K202,external trigger state> End of Read Cycle <K220,end of read cycle,read cycle timeout> Minimum Good Reads <K221,minimum good reads> Multisymbol <K222,number of symbols,multisymbol separator> Start Trigger Character <K229,start character> Stop Trigger Character <K230,stop character> Compare Mode <K233,status> Capture Mode <K241,capture mode,number of captures,rapid capture mode, pre-processing> Capture Timing <K242,time before first capture,time between first and second captures,,,,,,,,time between seventh and eighth captures> Image Storage <K244,image storage type,image store mode> IP Timeout <K245,image processing timeout>

Quadrus MINI Velocity User’s Manual

5-3

Page 102

Read Cycle Setup

Read Cycle Setup Setting up read cycle and triggering parameters will involve a series of decisions based on your particular application, as follows: 1. Select the number of symbols to be read in a single cycle. The Quadrus MINI Velocity can read multiple symbols in a single image frame. 2. Decide on the trigger type to be used: if serial, choose a serial character; if external, choose either Level or Edge. 3. Designate how the read cycle should end (Timeout, New Trigger, Last Frame). 4. Select Capture Mode, Continuous Mode, or Rapid Mode. 5. Select Number of Captures (if in Rapid Capture Mode). 6. Set the Time Before First Capture and Time Between Captures, if any. Note: The Quadrus MINI Velocity’s camera captures images at a rate of 60 per second (based on a full-size 752 x 480 image). The frame rate increases as the frame size decreases. Note: If you need to set up your Quadrus MINI Velocity for use with EZ Trax software, see Setting Up the Imager for EZ Trax.

5-4

Quadrus MINI Velocity User’s Manual

Page 103

Read Cycle

Multisymbol Usage: Definition: Conditions:

Multisymbol is commonly used in shipping applications where a shipping symbol contains individual symbols for part number, quantity, etc. This feature allows on trigger to pick up all the symbols. Multisymbol allows the user to define up to 100 symbols that can be read in a single read cycle. The following conditions apply: • Each symbol must be different to be read, unless in Rapid Capture Mode, configured for “triggered capture”. • The maximum number of characters in a read cycle is 3,000 for all symbols. • All No Read messages are posted at the end of the data string, unless output filtering is enabled. • If more than one symbol is within the field of view at the same time, symbol data may not be displayed in the order of appearance. • If Matchcode Type is set to Sequential or if Trigger is set to Continuous Read 1 Output, the imager will behave as if Number of Symbols were set to 1, regardless of the user-defined configuration.

Number of Symbols Definition: Serial Cmd: Default: Options:

Number of Symbols is the number of different symbols that can be read in a single read cycle. <K222,number of symbols, multisymbol separator> 1 1 to 100

Multisymbol Separator Usage: Definition:

Used to delimit or separate data fields with a user defined character. Any valid ASCII character, inserted between each symbol read when Multisymbol is set to any number greater than 1. Serial Cmd: <K222,number of symbols,multisymbol separator> Default: , (comma) Options: Any available ASCII character. Important: The ASCII characters <, >, and , can only be entered as hex pairs: For <: <K222h,,3C> For >: <K222h,,3E> For , : <K222h,,2C> See ASCII Character Entry Modifier on page 3-32 for a more detailed explanation of how to enter ASCII characters as hex values. Note: If No Read messages are disabled and there are No Reads occurring, separators will only be inserted between symbol data outputs. Quadrus MINI Velocity User’s Manual

5-5

Page 104

Trigger Mode and Filter Duration

Trigger Mode and Filter Duration Trigger Mode Definition:

Serial Cmd: Default: Options:

The Trigger is the event that initiates a read cycle. Note: When calibrating the imager or testing read rate, the current trigger setting will be disregarded. <K200,trigger mode,leading edge trigger filter,trailing edge trigger filter> Continuous Read 0 = Continuous Read 1 = Continuous Read 1 Output 2 = External Level 3 = External Edge 4 = Serial Data 5 = Serial Data and Edge

Continuous Read Usage: Definition:

Serial Cmd:

5-6

Continuous Read is useful in testing symbol readability or reader functions. It is not recommended for normal operations. In Continuous Read, trigger input options are disabled, the imager is always in the read cycle, and it will attempt to decode and transmit every capture. If a single symbol stays within read range for multiple read cycles, its data will be transmitted repeatedly until it leaves the read range. The imager sends replies to serial commands that require responses when symbol data is transmitted, or read cycle timeout is enabled and a timeout occurs and at least one captured image has been processed. Depending on the combination of enabled symbologies and the Threshold Mode setting, the imager may take longer than the timeout to process a captured image. Note: When to Output and No Read options have no affect on Continuous Read. <K200,0>

Quadrus MINI Velocity User’s Manual

Page 105

Read Cycle

Continuous Read 1 Output Usage:

Definition:

Serial Cmd:

Continuous Read 1 Output can be useful in applications where it is not feasible to use a trigger and all succeeding symbols contain different information. It is also effective in applications where the objects are presented by hand. In Continuous Read 1 Output the imager self-triggers whenever it decodes a new symbol or a timeout occurs. If End of Read Cycle is set to Timeout and the symbol doesn’t change, the output is repeated at the end of each timeout period. For example, if Timeout is set to one second, the imager sends the symbol data immediately and repeats the output at intervals of one second for as long as it continues to capture the symbol. If End of Read Cycle is set to New Trigger, the imager will send the current symbol data immediately, but only once. A new symbol appearing in the imager’s range will be read and sent immediately, provided it is not identical to the previous symbol. <K200,1>

Caution: In automated environments, Continuous Read 1 Output is not recommended because there is typically no reliable way to verify that a symbol was missed. Note: If Trigger Mode is set to Continuous Read 1 Output, the imager will behave as if Number of Symbols were set to 1, regardless of the user-defined configuration.

Quadrus MINI Velocity User’s Manual

5-7

Page 106

Trigger Mode and Filter Duration

External Level Initiate Read Cycle: Object #1, moving in front of the detector beam, causes a change in the trigger state, which initiates the read cycle. End Read Cycle: The same object, moving out of the detector beam, causes another change in the trigger state, which ends the read cycle.

Usage:

Definition:

Serial Cmd:

This mode is effective in an application where the speeds of the conveying apparatus are variable and the time the imager spends reading each object is not predictable. It also allows the user to determine if a No Read has occurred. External Level allows the read cycle (active state) to begin when a trigger (change of state) from an external sensing device is received. The read cycle persists until the object moves out of the sensor range and the active trigger state changes again. <K200,2>

Important: Level and Edge apply to the active logic state (Negative or Positive) that exists while the object is in a read cycle, between the rising edge and the falling edge. Rising edge is the trigger signal associated with the appearance of an object. Falling edge is the trigger signal associated with the subsequent disappearance of the object. This applies both to External Level and External Edge.

External Edge Initiate Read Cycle: Object # 1, moving in front of the detector beam, causes a change in the trigger state, which initiates the read cycle. Initiate Second Read Cycle: Object # 2, moving in front of the detector beam, causes another change in the trigger state. This signal initiates a new read cycle and ends the previous read cycle unless Timeout is enabled and a good read or timeout has not occured.

Usage: Definition:

Serial Cmd: 5-8

This mode is highly recommended in any application where conveying speed is constant, or if spacing, object size, or read cycle timeouts are consistent. External Edge, as with Level, allows the read cycle (active state) to begin when a trigger (change of state) from an external sensing device is received. However, the passing of an object out of sensor range does not end the read cycle. The read cycle ends with a good read output, or, depending on the End of Read Cycle setting, a timeout or new trigger occurs. <K200,3> Quadrus MINI Velocity User’s Manual

Page 107

Read Cycle

Serial Data Usage: Definition:

Serial Cmd:

Serial Data is effective in a highly controlled environment where the host knows precisely when the object is in the field of view. It is also useful in determining if a No Read has occurred. In Serial Data, the imager accepts an ASCII character from the host or controlling device as a trigger to start a read cycle. A Serial Data trigger behaves the same as an External Edge trigger. Serial commands are entered inside angle brackets, as shown here: <t>. <K200,4>

Note: In Serial Data, sending a non-delimited start serial character will start a read cycle; however, a non-delimited stop serial character has no effect.

Serial Data and Edge Usage:

Definition: Serial Cmd:

Serial Data or External Edge is seldom used but can be useful in an application that primarily uses an external sensing device but occasionally needs to be triggered manually. An auxiliary terminal can be connected to the auxiliary port so the user can send the serial trigger character through the imager to the host. In this mode the imager accepts either a serial ASCII character or an external trigger pulse to start the read cycle. <K200,5>

Note: In Serial Data, sending a non-delimited start serial character will start a read cycle; however, a non-delimited stop serial character has no effect.

Quadrus MINI Velocity User’s Manual

5-9

Page 108

Trigger Mode and Filter Duration

Leading Edge Trigger Filter Usage: Definition:

Serial Cmd: Default: Options:

Used to ignore spurious triggers when Trigger Mode is set to External Edge or External Level. To consider a change in state on the trigger input, the level must be stable for the trigger filter duration. In an edge mode, the imager will trigger a read cycle if the active state has been uninterrupted for the entire trigger filter duration. In a level mode, the leading edge is filtered such that on an active edge, the state must be held interrupted for the trigger filter duration before a trigger will occur. <K200,trigger mode,leading edge trigger filter,trailing edge trigger filter> 31 (1 ms) 1 to 65535 (Trigger filter range: 32.0 µs to 2.10 seconds)

Trailing Edge Trigger Filter Usage:

Used to ignore spurious triggers when Trigger Mode is set to External Edge or External Level.

Definition:

To consider a change in state on the trigger input, the level must be stable for the trigger filter duration. In an edge mode, the imager will trigger a read cycle if the active state has been uninterrupted for the entire trigger filter duration. In a level mode, the trailing edge is filtered such that on the falling edge, the state must be held for the trigger filter duration before the trigger will be deemed inactive. <K200,trigger mode,leading edge trigger filter,trailing edge trigger filter> 31 (1 ms) 1 to 65535 (Trigger filter range: 32.0 µs to 2.10 seconds)

Serial Cmd: Default: Options:

5-10

Quadrus MINI Velocity User’s Manual

Page 109

Read Cycle

External Trigger Polarity Usage: Definition: Serial Cmd: Default: Options:

Allows users to select the trigger polarity that will be used in their application. Determines the active state of the trigger signal applied to the cable input of the imager. <K202,active state> Positive 0 = Negative 1 = Positive

Quadrus MINI Velocity User’s Manual

5-11

Page 110

Serial Trigger

Serial Trigger Usage: Definition:

Allows the user to define the trigger character and delimiters that start and stop the read cycle. A serial trigger is considered an online host command and requires the same command format as all host commands. It must be entered within angle bracket delimiters < > or, in the case of non-delimited triggers, it must define individual start and stop characters.

Serial Trigger Character (Delimited) Usage: Definition:

Allows the user to define the trigger character that initiates the read cycle. A single ASCII host serial trigger character that initiates the read cycle. A delimited trigger character is one that either starts or ends the read cycle and is enclosed by delimiters such as < >. Serial Cmd: <K201,serial trigger character> Default: Space bar Options: Any single ASCII character, including control characters, except NUL (00 in hex), an existing host command character, or an on-line protocol character. Control characters entered on the command line are displayed in the menu as mnemonic characters. Note: Serial Data or Serial Data or External Edge triggering mode must be enabled for Serial Trigger Character to take effect. Important: The ASCII characters <, >, and , can only be entered as hex pairs: For <: <K201h,3C> For >: <K201h,3E> For , : <K201h,2C> See ASCII Character Entry Modifier on page 3-32 for a detailed explanation of how to enter ASCII characters as hex values.

5-12

Quadrus MINI Velocity User’s Manual