Manual · Microscan
Microscan MINI VELOCITY Quick Start
Manual2 pagesPDF 767 KB
Both pages are below, each with its text.
Covers · 1 model
The models it covers
From the manual · read page by page
Key facts from this manual
Each line names its page in the PDF.
A two-page Microscan quick start guide for the MINI Imager Series: the MINI Hawk Xi, MINI Hawk, Quadrus MINI and Quadrus MINI Velocity (as printed). It lists the setup hardware with part numbers and walks through connecting, positioning, installing ESP, calibrating and testing the read rate.
- Interfaces
- MINI Hawk, Quadrus MINI, Quadrus MINI Velocity: RS-232 / RS-422 / RS-485; MINI Hawk Xi: Ethernet p. 1
- Imager part number
- FIS-63X0-XXXXG (MINI Hawk Xi, MINI Hawk, Quadrus MINI, Quadrus MINI Velocity) p. 1
- Interface hardware
- IC-332 Adapter FIS-0001-0035G; IB-131 Interface Box 99-000018-01 p. 1
- Power supply
- 97-100004-15 (90-264 VAC, 24VDC, USA/Euro plug), connected to the IB-131 p. 1
- Other accessories
- Object Detector 99-000017-01; Communication Cable 61-300026-03 p. 1
- Focal distance
- 2" to 6" from the symbol; maximum skew ±30°, maximum pitch ±30° p. 1
- MINI Hawk Xi power
- MINI Hawk Xi only: Power Supply, M12 12-pin Socket, 1.3 m (Screw-On), 97-000003-03 p. 1
- Software
- ESP, on the Microscan Tools Drive packaged with the imager or from the Download Center p. 1
- Default read mode
- Continuous Read Mode p. 2
- EZ Button
- About 1 second: locate; about 2 seconds: calibrate; about 3 seconds: read rate test p. 2
- Serial commands
- <@CAL> starts calibration; <C> or <Cp> starts a read rate test, <J> ends it p. 2
What this manual walks you through
- Checking the required hardware p. 1
- Connecting the MINI Hawk Xi by Ethernet p. 1
- Connecting RS-232/422/485 imagers through the IB-131 and IC-332 p. 1
- Positioning the imager and test symbol p. 1
- Installing ESP p. 1
- Selecting the model and connecting with the Connection Wizard p. 2
- Locating the symbol by ESP or EZ Button p. 2
- Calibrating by EZ Button, ESP or serial command p. 2
- Testing the read rate p. 2
- Configuring and saving in App Mode p. 2
Good to know
- Connect all cables before applying power, and power down before disconnecting any cable. p. 1
- Keep decodable symbols out of the field of view while connecting, because the imager reads continuously by default. p. 2
- Five short beeps mean calibration failed and the imager stopped searching. p. 2
- The entire symbol should fall within the field of view. p. 2
Questions this manual answers
What is the part number of the IB-131 interface box for the Quadrus MINI Velocity?
The IB-131 Interface Box is 99-000018-01; the IC-332 Adapter is FIS-0001-0035G. p. 1
Which power supply does the Quadrus MINI Velocity use?
The guide lists power supply 97-100004-15 (90-264 VAC, 24VDC, USA/Euro plug), plugged into the IB-131 interface box. p. 1
How do I calibrate a Quadrus MINI Velocity with the EZ Button?
Hold the EZ Button about two seconds until two short beeps, then release; the imager searches camera settings for the best configuration. p. 2
Why won't ESP connect to my MINI imager?
The imager is in Continuous Read Mode by default, so keep any decodable symbol out of its field of view while connecting. p. 2
How far from the barcode should the imager be?
Between 2 and 6 inches from the symbol, tipped to avoid glare, with skew and pitch within ±30°. p. 1
The file
Size and text
Every page · 2
Read it here
Each page as it is printed, and its words beside it, so a phone can search and copy them.
Page1of 2
Open in the PDF
The text of page 1, from the PDF itself
Quick Start GuideStep 1, Check HardwareMINI Imager Series
FREE EXTENDED WARRANTY OFFER www.microscan.com/3year
1
3 Standard Warranty: One Year All Microscan products are backed by a one-year standard warranty. Full warranty details are online at www.microscan.com/warranty.
2
Extended Warranty: Three Years Register this product online with Microscan to receive complete extended warranty coverage for three years. LIMITED TIME OFFER: ACT NOW! To receive a FREE extended warranty, product MUST be registered by the end-use installation facility within four months of the date of manufacture. Online registration is available at www.microscan.com/3year.
714 5MINI Hawk Xi6
MINI Hawk, Quadrus MINI, Quadrus MINI Velocity
Hardware Required ItemDescriptionPart Number1
MINI Hawk Xi, MINI Hawk, Quadrus MINI, Quadrus MINI Velocity
FIS-63X0-XXXXG
2
Power Supply, M12 12-pin Socket, 1.3 m (Screw-On) (MINI Hawk Xi only)
97-000003-033IC-332 AdapterFIS-0001-0035G4IB-131 Interface Box99-000018-015
Power Supply (90-264 VAC, 24VDC, USA/Euro plug)
97-100004-156Object Detector99-000017-017Communication Cable61-300026-03P/N 83-116302 Rev E
Step 2, Connect the System MINI Hawk Xi – Ethernet
- Connect the M12 (power and I/O) end of the imager’s cable to the power supply (2).
- Connect the RJ45 (Ethernet) end of the imager’s cable to the host.
- Plug in the power supply to apply power to the imager.
MINI Hawk, Quadrus MINI, Quadrus MINI Velocity – RS-232 / RS-422 / RS-485
- Connect the imager (1) to the IB-131/IC-332 interface (4) and (3).
- Connect the communication cable (7) to the host, and to the host port on the IB-131.
- Connect the object detector (6) to the IB-131.
- Connect the power supply (5) to the IB-131.
- Plug in the power supply to apply power to the imager.
Step 3, Position Imager
- Place the imager and test symbol in a location with as little ambient light as possible.
- Position the imager at a focal distance between 2” and 6” from the symbol.
- Tip the imager relative to the symbol to avoid glare from specular reflection. Avoid excessive skew or pitch. Maximum skew is ±30°; maximum pitch is ±30°).
- Symbols can be rotated (tilted) at any angle; however, for best results symbols should be aligned with the FOV (field of view). In the case of linear symbols, aligning the bars in the direction of their movement (“ladder” orientation) will minimize the chances of blurring and No Reads.
ESP Software can be found on the Microscan Tools Drive that is packaged with the imager. 1. Follow the prompts to install ESP from the Tools Drive. 2. Click on the ESP icon to run the program.
Note: ESP can also be installed from the Download Center at www.microscan.com.
Refer to the user’s manual for detailed information about using ESP to configure the imager.
Caution: Be sure that all cables are connected BEFORE applying power to the system. Always power down BEFORE disconnecting any cables.
Imager / Symbol Positioning
Copyright ©2012 Microscan Systems, Inc.
Step 4, Install ESP
Page2of 2
Open in the PDF
The text of page 2, from the PDF itself
Step 5, Select Model When you start ESP, this menu will appear:
1. Click the button showing the imager used in your application. 2. Click OK. Note: You can also simply double-click the button showing your imager to make your selection. 3. Click Yes when this dialog appears:
Note: If you need to select another model later, click the Switch Model button near the top of the screen or use Model > New Model in the menu toolbar.
Step 8, Calibrate Imager settings can be adjusted automatically for optimum performance by either the EZ Button or by ESP. During the calibration routine, the imager will flash its Read Rate percent LEDs and illumination LEDs while searching camera settings and determining the best configuration for decoding symbol data. Upon successful completion of this routine, a green LED pattern will flash brightly and illuminate the symbol. If unsuccessful, the imager will emit 5 short beeps and stop searching.
Step 6, Connect To connect using the Connection Wizard:
Locate by ESP
- Click Connect on the menu toolbar, and then select Connection Wizard.
- Select the communication interface required by your application.
- Configure settings as required by the application, and click Connect.
- In ESP’s EZ Mode, click the Locate button to enable the blue target pattern. The symbol in the field of view will appear in the video view beneath the Locate and Calibrate buttons, and you will see the blue target pattern projected from the front of the imager.
- Center the target pattern on the symbol. At 2 to 3 inches, the pattern resembles an X. At 3 to 6 inches, the pattern resembles a V. Important: The entire symbol should fall within the field of view (FOV) of the imager. The field of view is what appears in ESP’s Locate/Calibrate window in EZ Mode.
- Click the Stop button to end the Locate function.
- When a connection is established, the green indicator in the status bar at the bottom right of the screen will be visible:
Important: The imager is in Continuous Read Mode by default. For best connection results, be sure that no decodable symbols are within the imager’s field of view while attempting to connect.
Step 9, Test Read Rate Read Rate indicates the number of successful decodes per second achieved by the imager.
1. Hold down the EZ Button for about two seconds and release when you hear two short beeps. The 20% and 40% LEDs will illuminate. 2. The imager will search camera settings to determine the best configuration for decoding symbol data. Note: To end all EZ Button functions, press the EZ Button once and quickly release.
Calibrate by ESP 1. Click the Calibrate button. 2. The imager will search camera settings to determine the best configuration for decoding symbol data. A successful calibration will display a green frame around the symbol, and the following message will appear: “Uploading all reader parameters.” After a moment the symbol data will be presented in the field below the image display window.
Calibrate by Serial Command Send <@CAL> from a terminal program to begin calibration. Copyright ©2012 Microscan Systems, Inc.
Locate by EZ Button If you are not connected to a host computer, the EZ Button allows you to locate the symbol in the imager’s field of view.
- Hold down the EZ Button for about one second and release when you hear one short beep. The amber 20% LED will illuminate, and you will see the blue target pattern projected from the front of the imager.
- Center the target pattern on the symbol. Note: To end all EZ Button functions, press the EZ Button once and quickly release.
Step 10, Configure and Save Click the App Mode button to make configuration changes to the imager.
Test Read Rate by EZ Button 1. To start the Read Rate test, hold down the EZ Button about three seconds until you hear three short beeps. The 20%, 40%, and 60% LEDs will illuminate. While the object is being inspected, the Read Rate LEDs will indicate the read rate percentage on the back of the unit. 2. To end the Read Rate test, press the EZ Button and quickly release.
Test Read Rate by ESP Calibrate by EZ Button
Step 7, Locate the Symbol
1. Click the Test button to start the Read Rate test and Stop to end it.
The following modes are accessible by clicking the buttons at the top of the screen:
MINI Hawk, Quadrus MINI, Quadrus MINI Velocity Read Rate LEDs and EZ Button
If a symbol has been successfully decoded, its data and related features will be presented in the field below the MINI Hawk Xi Read image display window. Also, while the object is being inspected, the Read Rate LEDs and EZ Rate LEDs will indicate the Read Rate Button percentage on the back of the unit. 2. To end the test, click the Stop button. Note: Read Rate can also be tested using the Read Rate interface in Utilities.
Test Read Rate by Serial Command You can also start a test with the <C> or <Cp> command and end it with the <J> command.
Click the EZ Mode button to return to EZ Mode. Click the Autoconnect button to establish communication. Click the Send/Recv button to send or receive commands. Click the Switch Model button to open the model menu, or to return to a previous model. Click the Parameters button to show the tabbed tree controls for Communication, Read Cycle, Symbologies, I/O Parameters, Symbol Quality, Matchcode, and Diagnostics. Click the Setup button to access a Camera Setup tree control and Video view, Evaluate image captures, Calibrate the imager, set the Window of Interest, load capture settings and processing settings in the Configuration Database, set up output filters and parse symbol data in Ordered Output and Output Format, and control multiple read cycle functions in Dynamic Setup. Click the Terminal button to display decoded symbol data, and to send serial commands to the imager using text or macros. Click the Utilities button to test Read Rate, request or clear Counters, enable or disable the imager or send output pulses in Device Control, determine the Differences from Default in the current settings, add or remove master symbol data in Master Database, and verify or update the imager’s Firmware. For further details, see ESP Help in the dropdown Help menu.