The text of a manual · part 11 of 13
MS-3000 Dual Head Decoder User's Manual, pages 101 to 110
Pages 101 to 110 of 126
The original document is the PDF (779 KB). This is its text as extracted, unedited; tables and drawings read best in the PDF, and each page heading opens it at that page.
For the Microscan MS-3000
Page 101
Useful Operations
2. Do not use Level in combination with External & Serial. The serial trigger will be ignored. 3. Avoid using New Trigger with Edge. A misread or noread can “hang” a scan head and cause missed reads on the other scan head. Table A-4 Outputs for Independent Configurations
1 External Trigger Type
2
3
4
5
6
7
8
9
10
11
12
Edge Edge Level Level Level Level Level Edge Level Level Edge Edge
When to Output ASAP EOR EOR ASAP EOR ASAP EOR EOR EOR ASAP ASAP EOR #1 Trigger
Ext.
Ext.
Ext.
Ext.
Ext.
Ext.
Ext. Cont Cont. Cont. Cont. Cont.
#2 Trigger
Ext.
Ext.
Ext.
Ext.
Ext.
Ext.
Ext.
Ext
Ext
Ext
Ext
Ext
#1 End of Cycle (T/O or NT)
T/O
T/O
T/O
T/O
T/O
NT
NT
T/O
T/O
T/O
T/O
T/O
#2 End of Cycle (T/O or NT)
T/O
T/O
T/O
NT
NT
T/O
T/O
T/O
T/O
T/O
T/O
T/O
Scan head #1 Good Read
0-3
3
F
0-3
0-3
0-F
F
Cont. Cont. Cont. Cont. Cont.
Scan head #1 Noread
3
3
F
F/3
F
F
F
Scan head #2 Good Read
0-9
6-9
F
0-
0-
0-
F+6
6-9
F
0-9
0-9
6-9
Scan head #2 Noread
6-9
6-9
F
F
F
0-
F+6
6-9
F
F/9
0-9
6-9
T/O = Timeout NT = New Trigger F = Fall = Infinity Timeout #1 = 3 seconds
Cont.= Continuous Ext.= External ASAP = As Soon As Possible EOR = End of Read Cycle Timeout #2 = 6 seconds
Table A-4 lists some valid good read/noread timing outputs for various independent configurations. Under column 1, for example, a decoder is con-
MS-3000 Dual Head Decoder User’s Manual
A-11
Appendices
Rules for Independent Mode 1. At any given time, only one scan head can be in read mode (since they must share a single processor).
Page 102
Appendices Appendices figured for Edge, As Soon as Possible, External trigger (both scan heads), and Timeout (both scan heads). Under these conditions a Good Read for scan head #1 must occur within three seconds following the external trigger signal. If not, a noread message is transmitted.
Dual Sequenced Timing In Sequenced mode, the two scan heads operate in concert with one another. They can be used together to track one or two labels, with either One Each or Multiple pass. The principal difference between Sequenced and Independent modes is that only one trigger is used in Sequenced to activate the read cycle. #1 Good Read
Scanner #1 Timeout Scanner #2 Timeout System Timeout
If Number of Labels is set to One, the decoder will stop reading when a label is detected. If Number of Labels is set to Two, the decoder will expect to see one label and one label only at each head.
If Number of Passes is set to One Each, each 0 3 6 9 12 scanner (starting with scanner #1) will search Figure A-8 Multiple Sequenced Output (ASAP) once only for a label(s). If Multiple is selected, System Timeout should also be enabled. If not, individual read cycles will repeat indefinitely if the label is not found. A system timeout might not always occur at the designated time because an individual cycle cannot be cut short by a system timeout. For example, in figure A-8 and in table A-5, column 1, a good read for scan head #1, if it occurs 11 seconds after the trigger, will turn over control to scan head #2. Scan head #2 starts its second search at 11 seconds and, failing to find a label, continues to search for six additional seconds for a total of 17 seconds. Thus, with these timing inputs it is possible for the system to remain active for up to 18 seconds.
A-12
MS-3000 Dual Head Decoder User’s Manual
Page 103
Useful Operations 1
2
3
4
5
6
7
8
External Trigger Type
Edge Edge Edge Edge Edge Edge Level Level
When to Output
ASAP ASAP EOR EOR EOR ASAP ASAP EOR
Number of Labels (1 or 2)
2
Passes (1 or Multiple)
2
2
2
2
2
2
2
M
1
M
1
1
1
M
M
#1 End of Cycle (T/O or NT) T/O
T/O
T/O
T/O
T/O
T/O
T/O
T/O
#2 End of Cycle (T/O or NT) T/O
T/O
T/O
T/O
NT
NT
T/O
T/O
#1 Good Read
0-3/ 9-12
0-3
12-18 6-9
NT
0-3
0-12
F
#2 Noread
12-18 6-9
12-18 6-9
NT
NT
0-18/F
F
#1 Noread
12
3
12-18
9
NT
3
12/F
F
#2 Good Read
3-9
3-9
12-18
9
NT
3-NT
3-9
F
#1 Good Read
0-12
0-3
6/12
6-9
NT
0-3
0-12
F
#2 Good Read
3-12
0-9
6/12
6-9
NT 0-3/NT 0-12
F
#1 Noread
12
3
12
9
NT
3
12/F
F
#2 Noread
12
9
12
9
NT
NT
12/F
F
T/O = Timeout NT = New Trigger F = Fall M = Multiple Timeout #1 = 3 seconds Timeout #2 = 6 seconds
ASAP = As Soon As Possible EOR = End of Read Cycle Cont.= Continuous Ext.= External System Timeout = 12
Table A-5 lists some valid Good Read and Noread timing outputs for various sequenced configurations. Because two different labels can be read in sequenced mode, there are now eight instead of four possible outputs for each configuration. Single label outputs, while not necessarily invalid, are not included here since their outputs depend on which scan head is in a read cycle when a label appears in the scan head's range or a falling edge signal occurs.
Rules for Sequenced Mode 1. Do not use Level in combination with External & Serial. The serial trigger will be ignored. 2. Avoid New Trigger except for scan head #2 when One Each is enabled for Number of Passes. 3. Do not disable System Timeout when Multiple is enabled for Number of Passes unless an indefinite delay is desired. MS-3000 Dual Head Decoder User’s Manual
A-13
Appendices
Table A-5 Read Output for Various Sequenced Settings
Page 104
Appendices
Appendices
Appendix F, Interfacing with the MS-90 Scan Head This appendix describes Label Speed, a User Outputs option (see figure A-9) that is exclusive to the MS-90 scan head. When using a MS-90 scan head with an MS-2000/3000 decoder, it is necessary to install MS-90 firmware (35-213034XX) that makes Label Speed available. 1
CURRENT SETTINGS FOR USER OUTPUTS = ON GOOD = LEVEL 4 = MEDIUM = ENABLED = MISMATCH OR NOREAD = DISABLED = POSITIVE = 50 ms
BEEPER BEEPER VOLUME LABEL SPEED FULL SCREENS RELAY DRIVER NEW MASTER PIN GOOD/BAD POLARITY GOOD/BAD PULSE WIDTH
Other than the differences noted in this appendix, configuration for the MS-90 is identical to standard single scan head configuration described in this manual.
ESC = MAIN MENU OR EXIT M = PREVIOUS MENU B = PREVIOUS ITEM
N = NEXT ITEM SP = NEXT ITEM CR = THIS ITEM
USER OUTPUTS - - > BEEPER = ON GOOD
Figure A-9 MS-90 User Outputs Menu (with Label Speed Option)
Label Speed Default: Options:
Medium Medium, Fast, Slow
Allows you to select a response time to match a specific label speed. For information on navigating the menus, see “ Using the Menu Configuration Program,” on page 2-2. The serial command format is explained below: Format: <KYlabel speed> label speed: 0 = Slow
1 = Medium
2 = Fast
Example: To set Label Speed to Fast, enter: <KY2> Note: When Label Speed is set to Fast, the beeper must be disabled. 1. The MS-90 firmware does not support Aux Port, New Master Pin, Beeper Speed, or the Microscan profile card.
A-14
MS-3000 Dual Head Decoder User’s Manual
Page 105
Interfacing with the MS-90 Scan Head
In general, the medium and fast settings will correspond with the high speed scan head and the slow setting will correspond with the low speed scan head (for more information, see the MS-90 Scan Head User’s Manual ). Table A-6 Label Speeds for Code 39 in Inches per Second
Narrow Bar Width Type
Menu Setting SLOW: Min. Max. MEDIUM:Min. Max. FAST:
Min. Max.
(wide-to-narrow ratio of 2.5:1)
6 mil. 0.4 10 2.5 57 18 368
7.5 mil. 0.5 12.9 3.1 71 29 460
10 mil. 0.7 17 4.2 95 30 600
15 mil. 1.0 25.9 6.3 143 45.6 600
20 mil. 1.4 34 8.3 190 61 600
30 mil. 2.1 52 12.5 286 91 600
Table A-7 Label Speeds for Code 128 in Inches per Second
Narrow Bar Width Type
Menu Setting SLOW: Min. Max. MEDIUM:Min. Max. FAST:
Min. Max.
(wide-to-narrow ratio of 2.5:1)
6 mil. 0.7 10 4 57 29 368
7.5 mil. 0.9 12.9 5 71 36 460
10 mil. 1.1 17 6.7 95 48 600
MS-3000 Dual Head Decoder User’s Manual
15 mil. 1.7 25.9 10 143 73 600
20 mil. 2.2 34 13.3 190 97 600
30 mil. 3.3 52 20 286 146 600
A-15
Appendices
Setting the correct label speed is important when using the MS-90 with the MS-3000 dual decoder. Tables A-6 and A-7 show label speeds in inches per second for Slow, Medium, and Fast menu label speeds for 2.5:1 ratio (as used in Code 39) and 4:1 ratio (as used in Code 128) respectively.
Page 106
Appendices
Appendices
Appendix G, Bar Code Symbology Some factors to consider before choosing a bar code symbol are: 1 • the type of information to be scanned (numeric only, alphanumeric)
• the length of the messages to be encoded • how and where labels are to be applied • label printer capabilities
• scan speed • beam width • the space available on the object to be identified • host software limitations • range of the scan head • the speed of the conveyor
Microscan standard decoder firmware supports the following five bar code symbologies. (Firmware can also be custom ordered to support other symbologies.) Code 39. An alphanumeric code with unique start/stop code patterns, composed of 9 black and white elements per character, 3 of which are always wide. Codabar. A 16-character set (0 through 9, and the characters $, :, /, ., +, and –) with start/stop codes and 18 different bar widths. I 2 of 5. Interleaved 2 of 5 is a high-density, continuous numeric symbology. I 2 of 5 encodes two digits: one in the bars, and one in the spaces. (A check digit is highly recommended.) UPC and EAN. UPC (Universal Product Code) is a fixed length numeric, continuous symbology. The European Article Numbering system (EAN) is a well-known variation of UPC. Both UPC and EAN can have 2 or 5 digit supplemental bar code data following the normal code. Code 128. A very high density alphanumeric symbology. Will encode all 128 ASCII characters, it is continuous, has variable length, and uses multiple element widths measured edge to edge.
1. For further information about symbology, see The Bar Code Book, by Roger C. Palmer, Helmers Publishing, Inc., 1989.
A-16
MS-3000 Dual Head Decoder User’s Manual
Page 107
Interface Standards
Interface Standards, established by the Electronic Industries Association (EIA), specify such things as the signaling voltage levels, maximum cable lengths, and number of drivers. With Microscan devices, selection of interface is made by pin assignment and, in the case of the host communications, by software switching between RS-232 and RS-422. Microscan devices use RS-232, RS-422, and RS-485 multidrop.
RS-232 RS-232 defines an interface between two devices such as, for example, the decoder and host. It differs from the other interfaces by dedicating individual pins to specific functions and by requiring both devices to share a common ground line. Since both device chassis are connected to a common ground, a ground loop potential and the possibility of noise interference exists. Therefore cable lengths are limited to a maximum of 50 feet (15.2 m). Despite being the most limited, this interface is used frequently because of the large installed base of RS-232 equipment.
RS-422 RS-422, unlike RS-232, measures signals differentially that is, the receiver looks at the potentials between the two receive (or transmit) wires rather than the potential between signal and ground. As a result, cables, if shielded, can be up to 4000 feet (1219.2 m) in length. Like RS-232, RS-422 communication is designed for only two devices on a single line. It can be used wherever RS-232 is used.
RS-485 RS-485, like RS-422, can transmit up to 4000 feet (1219.2 m) using differential voltages but unlike RS-422, its transmitters are turned off until a request for data is received from the host. RS-485 is used exclusively in Multidrop protocol. Note: See “Protocol,” on page 2-6 for additional information on standards.
MS-3000 Dual Head Decoder User’s Manual
A-17
Appendices
Appendix H, Interface Standards
Page 108
Appendices
Appendices
Appendix I, Auxiliary Monitor An auxiliary monitor, via a 9-pin cable connected to the decoder with a D-subminiature connector, can: 1. Echo data from the decoder or host. 2. Send data to the host. 3. Access and make changes to the decoder's configuration menus. The monitor can be configured to operate in one of three modes: • Transparent • Non-Buffered Half Duplex • Non-Buffered Full Duplex Note: Transparent can be used with all protocols. Full Duplex and Half Duplex operations can be used with any protocol except polled protocols. (Polling Mode D, Multidrop, User Defined, and User Defined Multidrop).
Transparent Mode Used to batch data from the monitor to the host. The decoder buffers data from the monitor and displays the keyed data on the monitor. The decoder transmits monitor data to the host when a label is scanned or a carriage return is entered from the monitor.
Data Initiated from the Monitor • Monitor data is passed through to the host whenever a return key is pressed at the monitor or whenever bar code data is sent. If sent with bar code data, it is processed on a firstin/first-out basis. • Monitor data to the host is always sent with a preamble and a postamble. • If the decoder is in a polled mode to the host, monitor data will still pass through.
Monitor
Host
PWR TRIG
SCA N
TRIG
SC AN
IND 1
IND 2
MS-3000 Dual Decoder
• A <D> command is the only command accepted by the decoder from the monitor. All other commands will pass through to the host.
A-18
MS-3000 Dual Head Decoder User’s Manual
Page 109
Auxiliary Monitor Appendices
Data initiated from the Decoder • Transmission to the monitor occurs immediately upon a good read. • Scan data to the monitor does not include a preamble or a postamble. • Communications with the monitor is always in Point-to-Point protocol, even if the host is in a polled protocol mode.
Monitor
Host
Data initiated from the Host
PWR TRIG
• In polled mode, data echoed from the host to the monitor must be in the format <B ____> (e.g., to send the word “LUNCH” to the monitor, it must be sent in the format <BLUNCH>).
TRIG
SCA N
SCAN
IND 1
IND 2
MS-3000 Dual Decoder
• In unpolled mode, all host data is echoed to the monitor.
Monitor
Host
Half Duplex Mode In half duplex mode all monitor data and bar code data is sent directly to the host. Bar code data is displayed on the monitor screen at the same time the data is sent to the host.
PWR TRIG
SCA N
TRIG
SC AN
IND 1
IND 2
MS-3000 Dual Decoder
Data initiated from the Monitor • Monitor data to the host is ignored if the decoder is in a polled mode. • Monitor data or scanned data is sent to the host whenever it is received. • Monitor data is not echoed.
Monitor
Host
• Monitor data to the host is always sent without a preamble or a postamble.
PWR TRIG
SCA N
TRIG
SC AN
IND 1
IND 2
MS-3000 Dual Decoder MS-3000 Dual Head Decoder User’s Manual
A-19
Page 110
Appendices Appendices
• <D> is the only command that is accepted by the decoder from the monitor. All other commands are passed through to the host.
Data initiated from the Decoder • Scan data is transmitted to the monitor at the same time it is transmitted to the host.
Monitor
Host
• Data transmission conforms with all parameters specified in the configuration menu (e.g., Preamble, Postamble, End of Read Cycle).
PWR TRIG
TRIG
SCA N
SC AN
IND 1
IND 2
MS-3000 Dual Decoder
Data is initiated from the Host • In polled mode, data echoed from the host to the monitor must be in the format <B____> (i.e.: to send the word “LUNCH” to the terminal, it must be sent in the format <BLUNCH>).
Monitor
Host
• In unpolled mode, all host data is echoed to the monitor. Note: For connection diagrams, see Chapter 1, “Setup and Installation .”
PWR TRIG
SCA N
TRIG
SC AN
IND 1
IND 2
MS-3000 Dual Decoder
A-20
MS-3000 Dual Head Decoder User’s Manual