For the Metrologic TECH 10

Page 1

METROLOGIC INSTRUMENTS, INC. TECH 10™ Laser Bar Code Projection Scanner (1070) Installation and User’s Guide

MLPN 2166 Printed in USA June 1998

Page 2

Locations:

USA Corporate Headquarters Metrologic Instruments, Inc. 90 Coles Road Blackwood, NJ 08012 Customer Service: 1-800-ID-METRO Tel: 609-228-8100 Fax: 609-228-6673 EMAIL: info@metrologic.com INTERNET: http://www.metrologic.com Mailing Address: P.O. Box 307 Bellmawr, NJ 08099-0307

South America Metrologic Instruments Centro Ciudad Comercial Tamanaco Torre B, piso 6, ofic. 603-B Chuao 1064 Caracas, Venezuela Tel: 58-2-959-8911 Fax: 58-2-959-9328 EMAIL: info@sa.metrologic.com

Europe Metrologic Instruments GmbH Dornierstrasse 2 82178 Puchheim b. Munich, Germany Tel: 49-89-89019-0 Fax: 49-89-89019-200 EMAIL: metrologic@europe.metrologic.com

ASIA Metrologic Asia (PTE) Ltd. 31, Kaki Bukit Road 3 #05-08, Techlink Singapore 417818 Tel: 65-842-7155 Fax: 65-842-7166 EMAIL: ant888@cyberway.com.sg

Brasil Metrologic do Brasil Ltda. Rua Florida, 1821-5 andar Brooklin-Sao Paulo-SP 04571-090 Brasil Tel: (011) 5505-2396 Fax: (011) 5507-2301 EMAIL: metrolog@br.metrologic.com Copyright © 1999 by Metrologic® Instruments, Inc. All rights reserved. No part of this work may be reproduced, transmitted, or stored in any form or by any means without prior written consent, except by reviewer, who may quote brief passages in a review, or provided for in the Copyright Act of 1976. Products and brand names mentioned in this document are trademarks of their respective companies.

ii

Page 3

Table of Contents Introduction . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

1

Unpacking List . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

1

Scanner Connections to the Host . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2 Configuration of the Scanner to the Host System . . . . . . . . . . . . . . . . . . . . . . 3 Parts of the Scanner . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4 Installation of the Stand . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 5, 6 Labels . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 7 Scanning Bar Codes . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

7

Maintenance . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 8 Appendix A Specifications . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

9, 10

Appendix B Pin Assignments for the Mil spec Connector . . . . . . . . . . . . . . . . . 11 Appendix C Warranty and Disclaimer . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 12, 13 Appendix D Notices . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 14, 15 Appendix E Patents . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 16 Index . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 17, 18 iii

Page 4

Introduction Metrologic's TECH 10 laser bar code projection scanner is encased in a NEMA-12 steel case. The scanner's construction enables the scanner to operate in harsh surroundings, especially industrial environments. Waterresistant, shock-resistant, and rugged, the TECH 10 scanner is also fast, aggressive and reliable. It can register bar codes at a range of 203mm 559mm (8" - 22") and can autodiscriminate among all common codes. Among the scanner’s many features is an Application Specific Integrated Circuit (ASIC) in the decoding system that virtually eliminates misreads; and MECCA© (Metrologic Enhanced Code Correcting Algorithm), which enables the scanner to read poorly printed, wrinkled or even torn bar codes on the first pass.

Unpacking List The following will be contained in the shipping carton: ! Installation and User’s Guide ! ScanSelect Scanner Programming Guide ! TECH 10 Laser Bar Code Projection Scanner ! Communication Cable with Power Supply (optional) or Communication Cable (optional) ! Stand (optional) To order additional items, contact the dealer, distributor or call Metrologic’s Customer Service Department.

1

Page 5

Scanner Connections to the Host In order for the TECH 10 scanner to maintain compliance with applicable standards, all circuits connected to the scanner (Example: power supply, host system, etc.) must meet the requirements for SELV (Safety Extra Low Voltage) according to EN60950. To avoid potential problems, do not power up the scanner until the communication cable is secured to the host. 1. Turn off the host system. 2. Locate the 19-pin female end of the scanner link cable and find the widest key located above pins L and A. Align this key with the corresponding key on the scanner box’s Mil spec connector. While pushing in on the connector, rotate the ring clockwise until it locks into place with a click. 3. Connect the other end of the communication cable to the host device. (If the scanner will not receive power from a transformer, skip to Step 6.) 4. If the scanner will receive power from an external power source, check the AC input requirements of the transformer to make sure the voltage matches the AC outlet. (A socket-outlet can be installed near the equipment and can be easily accessible.) 5. Plug the transformer into the AC outlet to supply the power to the scanner. 6. Power up the host system. 7. Scan a few items to verify that data is being properly transmitted between the scanner and the host device.

2

Page 6

Configuration of the Scanner to the Host System The scanner is shipped from the factory programmed to a set of default conditions noted in the ScanSelect™ Scanner Programming Guide by an asterisk that appears before the brief definition next to the bar code. In order for the scanner to communicate with the host system properly, it needs to be programmed to meet your specific scanning needs. Since each host system is unique, the scanner must be configured to match the host system requirements. The scanner can be configured by entering program mode and scanning the appropriate bar codes that appear in the ScanSelect Scanner Programming Guide. (When using ScanSet™, refer to the ScanSet documentation for information on how to configure the scanner.) 1. Connect the scanner to the host system (Refer to the Scanner Connections to the Host section in this guide). 2. Enter program mode by scanning the ENTER/EXIT program mode bar code. (The unit will beep three times) 3. Scan the appropriate bar code(s) that appear in the ScanSelect Scanner Programming Guide. (Reveal only one bar code to the scanner each time. With your hand, cover the bar code that should not be scanned.) 4. Exit program mode by scanning the ENTER/EXIT program mode bar code again. (The new options will be saved and the scanner is ready for normal operation.)

3

Page 7

Parts of the Scanner Becoming familiar with the features of the TECH 10 scanner will help when operating the scanner. The following illustration and list explain the pertinent parts.

4

1

Green and Red LEDs

When the green LED is on, this shows that the unit is receiving power and the laser is on. When the red LED flashes on, the scanner has read a bar code successfully. When the red light turns off, communication to the host is complete.

2

Laser Output Window

Laser light is emitted from this aperture.

3

Mil spec Connector

This is a 19-pin male Mil spec connector. It is used to connect the scanner to a host device by using a communication cable with a female Mil spec connector. The communication cable may include a power trans-former or it may be designed to draw power directly from the host device. The standard TECH 10 only contains one connector. If the scanner is being used with the MX001 box, then there will be two Mil spec connectors on the unit.