Browse
(440) 299-7778
Menu
(440) 299-7778
One-year parts and labor warranty30-day money-back guaranteeEnglishEspañolContact

The text of a manual · part 4 of 6

MS700i Series Laser Bar Code Projection Scanner Installation and User's Guide, pages 31 to 40

Pages 31 to 40 of 60

The original document is the PDF (818 KB). This is its text as extracted, unedited; tables and drawings read best in the PDF, and each page heading opens it at that page.

For the Metrologic MS700

Page 31

Depth of Field for the MS700i and MS715i Scanner Through the glass at the front of the scanner, safe, low powered laser beams are projected in a complex pattern that resembles a spider web. Each of the five scan fields that generate the scan pattern extends to a range of 178mm (7.0"). The range begins from the face of the scanner window and extends from the unit for a distance of 178mm (7.0") measured along the scanning beam at the center of each scan segment. This 0.0mm - 178mm (0" - 7") range is the depth of field for the MS700i and MS715i scanner (refer to Figure 10). This area of active scanning projects out from the glass on the face of the scanner to about 7 inches. The scan pattern is projected at a slight angle downward from the front of the scanner (approximately 10 degrees, overall). As the scan fields move outward, they expand. Like an image expands from a film projector as it moves toward the screen at a movie theater, the scan pattern projects out to a well-defined region. Any label that is facing toward the scanner can be read at any point within the scanning field.

Figure 10

27

Page 32

Depth of Field and Symbol Specification for the MS700i and MS715i (Refer to Figure 11) Code Type

UPC/EAN UPC/EAN Code 39 Code 39 Code 39 I 2 of 5 I 2 of 5 I 2 of 5 Codabar Codabar Codabar Code 93 Code 93 Code 128 Code 128

28

Minimum Small Element Mil. (1/1000") 10.4 13.0 7.5 12.0 21.0 7.5 12.0 21.0 7.5 12.0 21.0 10.4 13.0 10.4 13.0

Code Density

Depth of Field

80% 100% High Medium Low High Medium Low High Medium Low 80% 100% 80% 100%

0" - 5" 0" - 7" 0" - 4" 1" - 7" 3" - 11" 0" - 4" 1" - 7" 3" - 11" 0" - 4" 1" - 7" 3" - 11" 0" - 4" 1" - 7" 0" - 4" 1" - 7"

Page 33 read from a scan by OCR; it may hold reading errors

= .0210, - - - }, 5.0

H - 4.0, 3.0

.0120, - > MINIMUM -0130 BAR WIDTH = - | .0075, | .0104

- - 2.0, 1.0, 1.0

~

- - 2.0, 3.0

~.

H - 4.0 H - 5.0

| 0 1.0 2.0 3.0 4.0 5.0 6.0 7.0 8.0 9.010.011.0

DISTANCE: SCANNER FACE TO BAR CODE ¢ INCHES )

Figure 11

WIDTH OF HORIZONTAL SCAN FIELD ¢ INCHES)

29

Page 34

Depth of Field for the MS720i Scanner Through the glass at the front of the scanner, safe, low powered laser beams are projected in a complex pattern that resembles a spider web. Each of the five scan fields that generate the scan pattern extends to a range of 178mm (7.0"). The range begins 178mm (7.0") from the face of the scanner window and extends from the unit for a distance of 381mm (15.0") measured along the scanning beam at the center of each scan segment. This 178mm - 381mm (7" - 15") range is the depth of field for the MS720i scanner. (Refer to Figure 12)

The scan pattern is projected at a slight angle downward from the front of the scanner (approximately 10 degrees, overall). As the scan fields move outward, they expand. Like an image expands from a film projector as it moves toward the screen at a movie theater, the scan pattern projects out to a well-defined region. Any label that is facing toward the scanner can be read at any point within the scanning field.

Figure 12

30

Page 35

Depth of Field and Symbol Specification for the MS720i (Refer to Figure 13) Code Type

UPC/EAN UPC/EAN Code 39 Code 39 I 2 of 5 I 2 of 5 Codabar Codabar Code 93 Code 93 Code 128 Code 128

Minimum Small Element Mil. (1/1000") 10.4 13.0 12.0 21.0 12.0 21.0 12.0 21.0 10.4 13.0 10.4 13.0

Code Density

Depth of Field

80% 100% Medium Low Medium Low Medium Low 80% 100% 80% 100%

7" - 11" 7" - 15" 7" - 15" 9" - 17" 7" - 15" 9" - 17" 7" - 15" 9" - 17" 7" - 11" 7" - 15" 7" - 11" 7" - 15"

31

Page 36 read from a scan by OCR; it may hold reading errors

TOP VIEW OF SCANNER

-0210 -0130 MINIMUM BAR WIDTH -0120 -0104 . 0075 - ae =. --~ ea ~, se, ~.,, : ST a, oO

- N w f& oo0 0 90

No= - oo 0 oO Oo WIGTH OF HORIZONTAL SCAN FIELD ¢ INCHES )

a a | 0 1.0 2.0 3.0 4.0 5.0 6.0 7.0 9.0 9.0 10.011.0 DISTANCE: SCANNER FACE TO GAR CODE ¢ INCHES)

Figure 13

Page 37

Maintenance Smudges and dirt can interfere with the proper scanning of a bar code. Therefore, the output window will need occasional cleaning. 1. Spray glass cleaner onto lint free, non-abrasive cleaning cloth. 2. Gently wipe the scanner window.

Applications and Protocols The model number on each scanner includes the scanner number and communications protocol. Scanner

Version Identifier

700i/715i/720i/ 700i/715i/720i/ 700i/715i/720i/

1 and 21 2 26

700i/715i/720i/ 17 700i/715i/720i/ 11 and 24

Communication Protocol(s) RS-232, OCIA, Light Pen Emulation Parallel Output (OCR A/B) RS-232, OCIA, Light Pen Emulation, Point to Point RS-422 Keyboard Wedge, RS-232, Light Pen IBM 46XX - RS-485, RS-232, OCIA

The version “21” and “24” scanners are identical to the version “1” and “11” scanners, respectively, except for an EMI shell on the head cable.

33

Page 38

Appendix A Specifications Application: Light Source: CDRH: EMC:

UL/CSA/TUV: EMI:

Laser Bar Code Projection Scanner VLD 675 ± 5 nm, Maximum output 1mW CLASS IIa laser product EN 60950: 1993, EN 60825:1:1994, laser class 1, EN 55022:1987 Class A, EN 55082-1:1992, IEC 801-2:1991 8kVAD, IEC 1004-3:1995 3V/m (except version 11), IEC 801-3:1984 3V/m (version 11), IEC 801-4:1988 1kV Power Lines UL Listed, UL 114; CSA certified, C22.2 No. 950 TUV certified, GS Mark, EN 60825 and EN 60950 Complies with FCC & VDE Class A

Mechanical Dimensions: Footprint on Stand: Weight: Orientation: Mounting: Top Cover: Cable Length:

165mm x 165mm x 76mm (6.5"L x 6.5"W x 3.0"D) 64mm x 64mm (2.5" x 2.5") 1.13kg (2.5 lbs.) May be used in any orientation Fully adjustable optional mount High impact ABS plastic; easily replaced window 1.8mm (6') terminated with connector

Electrical Power Consumption: Voltage: Operating Current: Standby Current: DC Transformers:

8 watts, host system or tabletop power supply Input: 11-30 VDC 350mA @ 24 VDC 175mA @ 24 VDC 6113 (220V AC in), 6114 (120V AC in) and 6115 (240V AC in) output 24 VDC @ 750mA

Specifications subject to change without notice. Patent Numbers: 5,216,232; 5,081,342; 1,268,257; Other Patents Pending

34

Page 39

Operational Depth of Field: MS700i, MS715i MS720i

- 0.0mm - 178mm (0" - 7") - 178mm - 381mm (7" - 15")

Scan Speed: MS700i, MS720i MS715i

2000 scan lines per second 1000 scan lines per second

Scan Pattern:

5 scan fields: 1 horizontal, 4 at angles 1 horizontal scan field, 10 line pattern Projection Angle: 10E down off perpendicular of scan window Indicators: LED: green=laser on; red=good read Beeper Operation: 2 tones, 3 volume settings for “Good Read” Maintenance Required: Clean window periodically Decode Capability: Auto-discriminates System Interfaces: RS-232C/OCIA, Parallel, IBM® 468X/469X, Light Pen Emulation, Point to Point RS-422, PC Keyboard Wedge Print Contrast: 35% minimum reflectance difference

MS700i, MS720i MS715i

Roll, Pitch, Yaw: MS700i, MS720i MS715i

360E, 60E, 60E 42E, 60E, 52E

Environmental Storage Temperature: -40EC to 60EC (-40EF to 140EF) Operating Temperature: 0EC to 35EC (32EF to 95EF) Humidity: 5% to 95% relative humidity, non-condensing Light Levels: Up to 3200 foot candles; works in direct sunlight Ventilation: None required Shock: 100g for 1ms ESD: 15 kV IEC 801-2 Level 4 Contaminants: Sealed to resist airborne particulate contaminants Specifications subject to change without notice.

35

Page 40

Appendix B Default Settings Many functions of the scanner can be "programmed" - that is, enabled or disabled. The scanner is shipped from the factory programmed to a set of default conditions. The default parameter of the scanner has an asterisk ( * ) in the charts on the following pages. If an asterisk is not in the default column then the default setting is Off or Disabled. Every communication does not support every parameter. If the communication supports a parameter listed in the charts on the following pages, a check mark will appear. Parameter

Default

OCIA

IBM 46XX

RS232*

Parallel

Light Pen

UPC/EAN

*

T

T

T

T

T

Code 128

*

T

T

T

T

Code 93

*

T

T

T

T

Codabar

*

T

T

T

T

Interleaved 2 of 5 (ITF)

*

T

T

T

T

MOD 10 Check on ITF

T

T

T

T

Code 11

T

T

T

T

T

T

T

T

Full ASCII Code 39

T

T

T

T

MOD 43 Check on Code 39

T

T

T

T

MSI-Plessey

T

T

T

T

MSI-Plessey 10/10 Check Digit

T

T

T

T

T

T

T

T

MECCA

T

T

T

Paraf Support

T

T

T

T

T

T

Code 39

MSI-Plessey MOD 10 Check Digit

ITF Symbol Lengths 36

*

*

Variable

T

T T

T

T