Browse
(440) 299-7778
Menu
(440) 299-7778
One-year parts and labor warranty30-day money-back guaranteeEnglishEspañolContact
Page 1 of Logic Controls Logic Net LS-3000 Spec Sheet

Spec sheet · Logic Controls

Logic Controls Logic Net LS-3000 Spec Sheet

Spec sheet1 pagePDF 631 KB

The page is below, with its text.

Download the PDF631 KB

Covers · 1 model

The models it covers

From the sheet · read page by page

Key facts from this sheet

Some pages are scans or cannot be read; this says only what the readable text supports. Each line names its page in the PDF.

This one-page sheet describes the Logic Controls Logic Net LS3000 I/O station, a compact network module that connects peripheral devices to a Logic Net LM3000 control module. It covers the rugged case, the network design, mounting and how the module is updated.

Device
Network I/O station that drives peripheral devices, used with a Logic Net LM3000 control module p. 1
Enclosure
Heavy-duty zinc die cast case; no disk drives, fans or switches p. 1
Connectors
Snap-to-lock connectors p. 1
Network protocol
Poll/select with cyclic redundancy checks p. 1
Redundancy
Redundant data path so a broken line does not stop the network p. 1
Height and width
1.0 in high, 6.3 in wide p. 1
Mounting
Two mounting brackets: wall, ceiling, table top or under a counter p. 1
Firmware
Custom functions, fonts and firmware updates loaded by remote download p. 1
Development tool
Windows-based development tool and demo application for qualified customers p. 1

What this sheet walks you through

  • Adding I/O stations to a Logic Net network p. 1
  • Mounting the station in tight spaces p. 1

Questions this sheet answers

What control module does the Logic Net LS3000 work with?

The Logic Net LM3000 control module. p. 1

How is the LS3000 I/O station mounted?

With two mounting brackets, on a wall, ceiling, table top or under a counter. p. 1

Does the LS3000 need an interface card for peripherals?

No. The sheet says no special interface cards or extra hardware are needed for it to talk to peripheral devices. p. 1

The file

Size and text

Pages1
PDF631 KB
TextThe pages are scans; their text was read by OCR, which may hold reading errors.

Every page · 1

Read it here

Each page as it is printed, and its words beside it, so a phone can search and copy them.

Page 1 of Logic Controls Logic Net LS-3000 Spec Sheet

The text of page 1, read from a scan by OCR; it may hold reading errors

rut nr

® Reliable and rugged

= Configurable for zero single-point-of-failure = Powerful self-diagnostic capabilities

= Compact 1.0°h x 6.3”w x 5.17°d form factor

= Each module can drive multitude of peripheral devices

= Supports long network cable distance and has short wiring configuration

= High security = Simple to install, maintain and upgrade

@ Embedded custom functions, fonts and firmware updates easily added by remote downloading

= Windows-based development tool and demo application available for qualified customers

= Compatible with all operating systems = Certified with many standards

= Supports international operation

© LOGIC

‘CONTROLS

An Innovative Manufacturer Since 1982, _/\\U -~_/Logic Net®/ I/O Station

LIL Jot oC CJ CJ

Cost Effective

The LS3000 I/O stations, when used with a Logic Net® LM3000 control module, can replace costly PC workstations, network hubs and network software. To add more stations, simply increase the number of LS3000 modules. No special interface cards or additional hardware is required for the LS3000 module to

communicate with peripheral devices.

The LS3000 VO station was designed to meet the most demanding requirements of an industrial network. There are no disk drives, fans or mechanical parts that can easily fail. The enclosure is a heavy-duty zinc die cast case for extra ruggedness. Every module uses’ snap-to-lock connectors for secure connections. The LS3000 communicates with other workstations and the LM3000 control module using network communications protocols and topologies with proven reliability. It features high common-mode noise rejection network wiring. The poll/select protocol functionality avoids data collision, and the cyclic redundant checks virtually eliminate all communication errors. A zero single-point-of-failure configuration is also supported. LS3000 connections provide for a redundant data path to prevent network interruption due to a line breakage. The LS3000 has low power consumption that results in low internal temperature rise for higher mean time between failure. In addition, the units are tamper proof, with no on/off or selection switches and no

adjustable devices.

Ultra Compact

The LS3000 has a very compact form factor, only 1.0”h x 6.3”w x 5.1’d. Two mounting brackets enable these modules to be mounted almost anywhere, on a wall, ceiling, table top or under a counter. This enables it to be used in a wide variety of applica-tions, on a production line, in a restaurant’s kitchen system, etc., despite severe space constraints.

More documents · 1

For the same models