Spec sheet · Leuze
Leuze VSU 12 Spec Sheet
Spec sheet4 pagesPDF 213 KB
All 4 pages are below, each with its text.
Covers · 1 model
The models it covers
From the sheet · read page by page
Key facts from this sheet
Each line names its page in the PDF.
Leuze spec sheet for the VSU 12 ultrasonic splice inspection system, made of a VSU 12/4.4 or VSU 12/4.5 evaluation amplifier and a DB 18 UP sensor pair. It lists specifications and part numbers and explains mounting, paper or foil mode and the adjustments.
- What it is
- Ultrasonic splice detector: VSU 12/4… evaluation amplifier with a DB 18 UP sensor pair p. 3
- Web materials
- Paper, plastic or metal web on roll machines p. 3
- Web speed
- Up to 1000m/min p. 1
- Operating voltage
- 10 … 30VDC (incl. residual ripple) p. 2
- Outputs
- Short-circuit proof PNP transistor outputs, max. 200mA per output p. 1, 2
- Ambient temperature
- 0°C … +60°C operation, -40°C … +70°C storage p. 2
- Versions
- VSU 12/4.4: splice and material-not-detectable outputs; VSU 12/4.5: splice output plus paper tear detection on PIN 2 p. 3
- Part No.
- 501 11731 (VSU 12 splice inspection) p. 1
- Sensor pair
- DB 18 UP.1-25, 2500, part no. 501 08998; ultrasonic, M18 round-sleeve housing p. 1, 2
- Paper or foil mode
- Switch S1: 0 = paper, 1 = foil (higher sensitivity); or PIN 5 high (≥ 8V) for foil p. 3
- Adjustments
- P1 pulse stretching up to 200ms; P2 sensitivity (full right = maximum) p. 3
- Accessories
- M12 connectors (KD …), ready-made cables (KB …), 5-pin cable KB-095-5000-5A p. 1
What this sheet walks you through
- Mounting and aligning the transmitter and receiver p. 3, 4
- Choosing paper or foil mode p. 3
- Lowering sensitivity to stop false splice signals p. 3
- Setting the length of the output pulse p. 3
Good to know
- The sensors must sit at 65° (± 2°) to the web for proper function. p. 4
- Alignment must be exact to ± 1°; misalignment reduces the working range. p. 3
- The web must run approx. 8 … 10mm above the transmitter. p. 3
- To switch paper or foil through PIN 5, switch S1 must be at 0 (paper). p. 3
Questions this sheet answers
What materials can the VSU 12 detect splices on?
Paper, plastic or metal web used on roll machines. p. 3
How fast can the web run past the VSU 12?
Up to 1000 m/min. p. 1
How do I switch the VSU 12 between paper and foil?
Set switch S1 to 0 for paper or 1 for foil; with S1 at 0, a high level (≥ 8V) on PIN 5 also selects foil. p. 3
How far apart should the VSU 12 transmitter and receiver be?
25mm (± 5mm), both at 65° (± 2°) to the sheet. p. 3
How do I stop false splice signals?
Turn potentiometer P2 left to lower the sensitivity. p. 3
The file
Size and text
Every page · 4
Read it here
Each page as it is printed, and its words beside it, so a phone can search and copy them.
Page1of 4
Open in the PDF
The text of page 1, from the PDF itself
VSU 12Splice inspectionPart No. 501 11731Dimensioned drawing20 … 40mm 10 - 30 V DC
z Reliable detection of splice on paper web or plastic web z Sheet speeds up to 1000m/min z Automatic adaptation to the medium z High acoustic power (guaranteeing reliable functionality even for thick materials) z Ultrasonic sensor in the M18 round-sleeve housing z Plug connection z Short-circuit proof PNP transistor outputs operating-state indication by means of LEDs z Sensors have a very short construction (can thus also be used in applications with limited available space) z Paper tear detection (...4.5)
A B C
Transmitter DB 18 U (P) Receiver DB 18 U (P) Indicator diodes
We reserve the right to make changes • VSU_12_gb.fm
Electrical connection IP 65
IEC 60947...IEC 60947...VSU 12/4.4VSU12/4.5
Accessories: (available separately)
z M12 connectors (KD …) z Ready-made cables (KB …) 5-pin: KB-095-5000-5A
Leuze electronic GmbH + Co. KG info@leuze.de • www.leuze.com
In der Braike 1 D-73277 Owen Tel. +49 (0) 7021 573-0
VSU 12/4.4(.5) - 03 DB 18 UP.1 - 03
Page2of 4
Open in the PDF
The text of page 2, from the PDF itself
VSU 12 SpecificationsTablesSensor dataDB 18 UP
Operating range (recommended) Operating range limit Converter frequency Sound cone
25mm 20 … 40mm 200kHz ± 2% approx. 12°
VSU 12/4.4.../4.5
Timing Web speed
max. 1000m/min min.≥ 6mm/s (with 30mm splice width) path clear/ inserted medium < 5s ≤ 100ms 0 … 200ms, adjustable
Recovery-time constant (LED A flashes briefly) Delay before start-up Pulse stretching
Electrical data Operating voltage UB
10 … 30VDC (incl. residual ripple) ≤ 15% of UB ≤ 75mA
Residual ripple Bias current Outputs Tape Function
PNP transistor output forced tripping of transistor when splice detected PNP transistor output forced tripping of transistor when material not detectable
VSU 12/4.5 Web material (paper tear) Function
PNP transistor output forced tripping of transistor when material present between the sensors ≥ (UB -2V)/≤ 2V max. 200mA per output
Signal voltage high/low Output current
Indicators VSU 12/4.4 LED B green LED D green LED C yellow LED A red flashing
foil selected paper selected splice detected material not detectable
Diagrams Splice width in dependence of web speed 70
Splice width [mm]
Level under limit Function
60 50 40 30 20 10 0010203040Web speed [m/s]
VSU 12/4.5 LED A red flashing LED A yellow
material not detectable paper tear
Mechanical data Housing Weight Connection type
nickel-faced brass 30g M8 connector, 3-pin, with 2m cable
aluminum, powder coated black 400g M12 connector, 5-pin
Environmental data Ambient temp. (operation/storage) Protective circuit 1) VDE safety class Protection class Standards applied
0°C … +60°C/-40°C … +70°C 1,2,3 III IP 65 EN 60947-5-2
Note
Options Commutation input Paper/Foil 2) Paper mode Foil mode
0V or not connected ≥ 8V
1) 1=transient protection, 2=polarity reversal protection, 3=short circuit protection 2) Switch S1 must be in position 0 "Paper"
Order guide Designation
Part No.Sensor pairDB 18 UP.1-25, 2500501 08998AmplifierVSU 12/4.4 VSU 12/4.5501 04022 501 04139
VSU 12/4.4(.5) - 03 DB 18 UP.1 - 03
0904
Page3of 4
Open in the PDF
The text of page 3, from the PDF itself
VSU 12 Technical description General The ultrasonic system for splice detection consists of a VSU 12/4… evaluation amplifier and a DB 18 UP ultrasonic sensor pair. It mainly detects splices on paper, plastic or metal web used on roll machines. Mounting Transmitter and receiver (DB 18 UP) have the same construction and are to be mounted at an angle of 65° (± 2°) relative to the sheet. The distance between transmitter and receiver should be 25mm (± 5mm). Exact alignment (± 1°) must be ensured. Alignment which is not in line with the axis results in a reduction of the working range. The material to be scanned must be located approx. 8 … 10mm above the transmitter. The pitch of the sensors should be parallel to the tape or, as the case may be, splices. Function The evaluation unit can be operated in two different modes. a) Parameter switch S1 in position "0" (paper) The sheet is either paper or cardboard. b) Parameter switch S1 in position "1" (foil) The sheet is either plastic or metalised foil. The amplifier has a higher sensitivity.
The changeover from "paper" to "foil" can also be performed via PIN 5 "Paper/Foil". Low-level on connection 5 means "paper", high-level (≥ 8V) on connection 5 means "foil". The parameter switch S1 must be in position 0 "paper" in order to use this feature (state on delivery). Adjusting the sensitivity (P2) Inhomogeneities in the web material may lead to erroneous switching in the detection of glued seams. These faults may generate signals even if there is no glued seam. By lowering the sensitivity via the potentiometer P2 (turn left), this erroneous switching may be alleviated. Full right turn position on P2 corresponds to maximum sensitivity (factory setting). Operation VSU 12/4.4 The VSU 12/4.4 evaluation unit automatically adapts to the acoustic transmissivity of the medium. As soon as a splice is detected, the "splice detected" output (tape) is triggered. The duration of the output signal can be set via the potentiometer (pulse stretching) P1. The maximum time which can be set is 200ms. A detected splice is indicated on LED C. If the level is not sufficient for reliable detection, the "Material not detectable" output (Level under Limit) is triggered. This is also signalled via the red flashing LED A. Operation VSU 12/4.5 The VSU 12/4.5 evaluation unit automatically adapts to the acoustic transmissivity of the medium. As soon as a splice is detected, the "splice detected" output (tape) is triggered. The duration of the output signal can be set via the potentiometer (pulse stretching) P1. The maximum time which can be set is 200ms. A detected splice is indicated on LED C. If the level is not adequate for reliable detection, this is indicated by the red, flashing LED A. As soon as the system detects a paper tear or if no material is present between the sensors, this is indicated at PIN 2 via the PNP output.
Leuze electronic GmbH + Co. KG info@leuze.de • www.leuze.com
In der Braike 1 D-73277 Owen Tel. +49 (0) 7021 573-0
VSU 12/4.4(.5) - 03 DB 18 UP.1 - 03
Page4of 4
Open in the PDF
The text of page 4, from the PDF itself
VSU 12 Controls and indicators Display (see Specifications) Adjustment (see Specifications)
A B C D
Red LED Green LED Yellow LED Green LED
P1
Potentiometer 0 … 200ms pulse stretching Potentiometer sensitivity adjustment Foil/Paper switch 0 = paper 1 = foil
P2 S1
Mounting and notes Note z When aligning the sender and receiver, the best possible alignment must be ensured. z For proper function, the sensors must be positioned at an angle of F = 65° (± 2°) relative to the web.
VSU 12/4.4(.5) - 03 DB 18 UP.1 - 03
A B C D E F
Receiver Outer edge Tape min. 15mm wide Paper or foil web Transmitter Pitch relative to the direction of travel
A B C D E F
Receiver Holder Transmitter Paper or foil web Direction of travel Splice
0904