Leuze spec sheet for the VSU 12 ultrasonic splice inspection system, made of a VSU 12/4.4 or VSU 12/4.5 evaluation amplifier and a DB 18 UP sensor pair. It lists specifications and part numbers and explains mounting, paper or foil mode and the adjustments.

What it is
Ultrasonic splice detector: VSU 12/4… evaluation amplifier with a DB 18 UP sensor pair p. 3
Web materials
Paper, plastic or metal web on roll machines p. 3
Web speed
Up to 1000m/min p. 1
Operating voltage
10 … 30VDC (incl. residual ripple) p. 2
Outputs
Short-circuit proof PNP transistor outputs, max. 200mA per output p. 1, 2
Ambient temperature
0°C … +60°C operation, -40°C … +70°C storage p. 2
Versions
VSU 12/4.4: splice and material-not-detectable outputs; VSU 12/4.5: splice output plus paper tear detection on PIN 2 p. 3
Part No.
501 11731 (VSU 12 splice inspection) p. 1
Sensor pair
DB 18 UP.1-25, 2500, part no. 501 08998; ultrasonic, M18 round-sleeve housing p. 1, 2
Paper or foil mode
Switch S1: 0 = paper, 1 = foil (higher sensitivity); or PIN 5 high (≥ 8V) for foil p. 3
Adjustments
P1 pulse stretching up to 200ms; P2 sensitivity (full right = maximum) p. 3
Accessories
M12 connectors (KD …), ready-made cables (KB …), 5-pin cable KB-095-5000-5A p. 1

What this sheet walks you through

  • Mounting and aligning the transmitter and receiver p. 3, 4
  • Choosing paper or foil mode p. 3
  • Lowering sensitivity to stop false splice signals p. 3
  • Setting the length of the output pulse p. 3

Good to know

  • The sensors must sit at 65° (± 2°) to the web for proper function. p. 4
  • Alignment must be exact to ± 1°; misalignment reduces the working range. p. 3
  • The web must run approx. 8 … 10mm above the transmitter. p. 3
  • To switch paper or foil through PIN 5, switch S1 must be at 0 (paper). p. 3

Questions this sheet answers

What materials can the VSU 12 detect splices on?

Paper, plastic or metal web used on roll machines. p. 3

How fast can the web run past the VSU 12?

Up to 1000 m/min. p. 1

How do I switch the VSU 12 between paper and foil?

Set switch S1 to 0 for paper or 1 for foil; with S1 at 0, a high level (≥ 8V) on PIN 5 also selects foil. p. 3

How far apart should the VSU 12 transmitter and receiver be?

25mm (± 5mm), both at 65° (± 2°) to the sheet. p. 3

How do I stop false splice signals?

Turn potentiometer P2 left to lower the sensitivity. p. 3

The file

Size and text

Pages4
PDF213 KB
TextText from the PDF itself.

Every page · 4

Read it here

Each page as it is printed, and its words beside it, so a phone can search and copy them.

Page 1 of Leuze VSU 12 Spec Sheet

The text of page 1, from the PDF itself

VSU 12Splice inspectionPart No. 501 11731Dimensioned drawing20 … 40mm 10 - 30 V DC

z Reliable detection of splice on paper web or plastic web z Sheet speeds up to 1000m/min z Automatic adaptation to the medium z High acoustic power (guaranteeing reliable functionality even for thick materials) z Ultrasonic sensor in the M18 round-sleeve housing z Plug connection z Short-circuit proof PNP transistor outputs operating-state indication by means of LEDs z Sensors have a very short construction (can thus also be used in applications with limited available space) z Paper tear detection (...4.5)

A B C

Transmitter DB 18 U (P) Receiver DB 18 U (P) Indicator diodes

We reserve the right to make changes • VSU_12_gb.fm

Electrical connection IP 65

IEC 60947...IEC 60947...VSU 12/4.4VSU12/4.5

Accessories: (available separately)

z M12 connectors (KD …) z Ready-made cables (KB …) 5-pin: KB-095-5000-5A

Leuze electronic GmbH + Co. KG info@leuze.de • www.leuze.com

In der Braike 1 D-73277 Owen Tel. +49 (0) 7021 573-0

VSU 12/4.4(.5) - 03 DB 18 UP.1 - 03

Page 2 of Leuze VSU 12 Spec Sheet

The text of page 2, from the PDF itself

VSU 12 SpecificationsTablesSensor dataDB 18 UP

Operating range (recommended) Operating range limit Converter frequency Sound cone

25mm 20 … 40mm 200kHz ± 2% approx. 12°

VSU 12/4.4.../4.5

Timing Web speed

max. 1000m/min min.≥ 6mm/s (with 30mm splice width) path clear/ inserted medium < 5s ≤ 100ms 0 … 200ms, adjustable

Recovery-time constant (LED A flashes briefly) Delay before start-up Pulse stretching

Electrical data Operating voltage UB

10 … 30VDC (incl. residual ripple) ≤ 15% of UB ≤ 75mA

Residual ripple Bias current Outputs Tape Function

PNP transistor output forced tripping of transistor when splice detected PNP transistor output forced tripping of transistor when material not detectable

VSU 12/4.5 Web material (paper tear) Function

PNP transistor output forced tripping of transistor when material present between the sensors ≥ (UB -2V)/≤ 2V max. 200mA per output

Signal voltage high/low Output current

Indicators VSU 12/4.4 LED B green LED D green LED C yellow LED A red flashing

foil selected paper selected splice detected material not detectable

Diagrams Splice width in dependence of web speed 70

Splice width [mm]

Level under limit Function

60 50 40 30 20 10 0010203040Web speed [m/s]

VSU 12/4.5 LED A red flashing LED A yellow

material not detectable paper tear

Mechanical data Housing Weight Connection type

nickel-faced brass 30g M8 connector, 3-pin, with 2m cable

aluminum, powder coated black 400g M12 connector, 5-pin

Environmental data Ambient temp. (operation/storage) Protective circuit 1) VDE safety class Protection class Standards applied

0°C … +60°C/-40°C … +70°C 1,2,3 III IP 65 EN 60947-5-2

Note

Options Commutation input Paper/Foil 2) Paper mode Foil mode

0V or not connected ≥ 8V

1) 1=transient protection, 2=polarity reversal protection, 3=short circuit protection 2) Switch S1 must be in position 0 "Paper"

Order guide Designation

Part No.Sensor pairDB 18 UP.1-25, 2500501 08998AmplifierVSU 12/4.4 VSU 12/4.5501 04022 501 04139

VSU 12/4.4(.5) - 03 DB 18 UP.1 - 03

0904

Page 3 of Leuze VSU 12 Spec Sheet

The text of page 3, from the PDF itself

VSU 12 Technical description General The ultrasonic system for splice detection consists of a VSU 12/4… evaluation amplifier and a DB 18 UP ultrasonic sensor pair. It mainly detects splices on paper, plastic or metal web used on roll machines. Mounting Transmitter and receiver (DB 18 UP) have the same construction and are to be mounted at an angle of 65° (± 2°) relative to the sheet. The distance between transmitter and receiver should be 25mm (± 5mm). Exact alignment (± 1°) must be ensured. Alignment which is not in line with the axis results in a reduction of the working range. The material to be scanned must be located approx. 8 … 10mm above the transmitter. The pitch of the sensors should be parallel to the tape or, as the case may be, splices. Function The evaluation unit can be operated in two different modes. a) Parameter switch S1 in position "0" (paper) The sheet is either paper or cardboard. b) Parameter switch S1 in position "1" (foil) The sheet is either plastic or metalised foil. The amplifier has a higher sensitivity.

The changeover from "paper" to "foil" can also be performed via PIN 5 "Paper/Foil". Low-level on connection 5 means "paper", high-level (≥ 8V) on connection 5 means "foil". The parameter switch S1 must be in position 0 "paper" in order to use this feature (state on delivery). Adjusting the sensitivity (P2) Inhomogeneities in the web material may lead to erroneous switching in the detection of glued seams. These faults may generate signals even if there is no glued seam. By lowering the sensitivity via the potentiometer P2 (turn left), this erroneous switching may be alleviated. Full right turn position on P2 corresponds to maximum sensitivity (factory setting). Operation VSU 12/4.4 The VSU 12/4.4 evaluation unit automatically adapts to the acoustic transmissivity of the medium. As soon as a splice is detected, the "splice detected" output (tape) is triggered. The duration of the output signal can be set via the potentiometer (pulse stretching) P1. The maximum time which can be set is 200ms. A detected splice is indicated on LED C. If the level is not sufficient for reliable detection, the "Material not detectable" output (Level under Limit) is triggered. This is also signalled via the red flashing LED A. Operation VSU 12/4.5 The VSU 12/4.5 evaluation unit automatically adapts to the acoustic transmissivity of the medium. As soon as a splice is detected, the "splice detected" output (tape) is triggered. The duration of the output signal can be set via the potentiometer (pulse stretching) P1. The maximum time which can be set is 200ms. A detected splice is indicated on LED C. If the level is not adequate for reliable detection, this is indicated by the red, flashing LED A. As soon as the system detects a paper tear or if no material is present between the sensors, this is indicated at PIN 2 via the PNP output.

Leuze electronic GmbH + Co. KG info@leuze.de • www.leuze.com

In der Braike 1 D-73277 Owen Tel. +49 (0) 7021 573-0

VSU 12/4.4(.5) - 03 DB 18 UP.1 - 03

Page 4 of Leuze VSU 12 Spec Sheet

The text of page 4, from the PDF itself

VSU 12 Controls and indicators Display (see Specifications) Adjustment (see Specifications)

A B C D

Red LED Green LED Yellow LED Green LED

P1

Potentiometer 0 … 200ms pulse stretching Potentiometer sensitivity adjustment Foil/Paper switch 0 = paper 1 = foil

P2 S1

Mounting and notes Note z When aligning the sender and receiver, the best possible alignment must be ensured. z For proper function, the sensors must be positioned at an angle of F = 65° (± 2°) relative to the web.

VSU 12/4.4(.5) - 03 DB 18 UP.1 - 03

A B C D E F

Receiver Outer edge Tape min. 15mm wide Paper or foil web Transmitter Pitch relative to the direction of travel

A B C D E F

Receiver Holder Transmitter Paper or foil web Direction of travel Splice

0904