The text of a manual · part 94 of 105
Catalog: Optical electronic sensors: Protective Photoelectric Sensors – Type 2, pages 907 to 916
Pages 907 to 916 of 1000, from Catalog: Optical electronic sensors
The original document is the PDF (46 MB). This is its text as extracted, unedited; tables and drawings read best in the PDF, and each page heading opens it at that page.
For the Leuze FRK 92, Leuze PRK406 and Leuze PRK 3
Page 907
Page 908
Leuze electronic TNT 33
Test monitoring unit Dimensioned drawing
Electrical connection
TÜV Baumuster
24 V DC
BWS Typ 2
We reserve the right to make changes • SLS_s02e.fm l High security through permanent cyclic test in time intervals of 2 sec. l Highest operating safety through microcontroller technique l Security relay output with fault protected monitoring l No interruption of operation during test procedure l Connection possibility for all current testable protective photoelectric sensors l Integrated muting switching input l Optical coupler inputs for high interference protection l Separate signalling outputs as PNP transistor outputs l Integrated start and restart-disable
ISO 9001
IEC 60947...
Accessories: (available separately)
l Safety muting controller - SMC 33 (Part No. 500 28157) - SMC 34 (Part No. 500 82120)
Leuze electronic GmbH + Co. http://www.leuze.de
A B C D E F G H I
Transmitter Switching output receiver Receiver SMC 33 Internal GND connections Signal outputs PNP, max. 100mA Relay monitoring Optical coupler Reference GND = UB–GND
Post-box 1111 D-73277 Owen-Teck Tel. ++49 7021 5730
– 908 –
TNT 33 - 02
Page 909
Page 910
Leuze electronic TNT 34
Test monitoring unit Dimensioned drawing
Electrical connection
TÜV Baumuster
24 V DC
BWS Typ 2
We reserve the right to make changes • SLS_s03e.fm l High security through permanent cyclic test in time intervals of 2 sec. l Highest operating safety through microcontroller technique l Security relay output with fault protected monitoring l No interruption of operation during test procedure l Connection possibility for all current testable protective photoelectric sensors l Integrated muting switching input l Optical coupler inputs for high interference protection l Separate signalling outputs as PNP transistor outputs
ISO 9001
IEC 60947...
Accessories: (available separately)
l Safety muting controller - SMC 33 (Part No. 500 28157) - SMC 34 (Part No. 500 82120)
Leuze electronic GmbH + Co. http://www.leuze.de
A B C D E F G H
Transmitter Switching output receiver Receiver SMC 33 Internal GND connections Signal outputs PNP, max. 100mA Optical coupler Reference GND = UB–GND
Post-box 1111 D-73277 Owen-Teck Tel. ++49 7021 5730
– 910 –
TNT 34 - 02
Page 911
Page 912
Leuze electronic TNT 35
Test monitoring unit Dimensioned drawing
Electrical connection
TÜV Baumuster
24 V DC
BWS Typ 2
We reserve the right to make changes • SLS_s07e.fm l High security through permanent cyclic test in time intervals of 2 sec. l Highest operating safety through microcontroller technique l Security relay output with fault protected monitoring l No interruption of operation during test procedure l Connection possibility for all current testable protective photoelectric sensors l Optical coupler inputs for high interference protection l Separate signalling outputs as PNP transistor outputs l Selectable start and restart-disable
ISO 9001
IEC 60947...
Accessories:
A B C D E
F G H I J K L
Leuze electronic GmbH + Co. http://www.leuze.de
Transmitter Receiver Operation with start/restart-disable Operation without start-/restart-disable Selection of the operating mode by bridging: terminal 22 and 23 (with start/restart-disable) or terminal 23 and 24 (without start/restart-disable) Factory setting for the bridge is between terminals 22 and 23 (with start/restart-disable function) EDM (contactor monitoring, feedback control loop) Safety relay output 2 EMERGENCY SHUTDOWN Safety relay output 1 Signal output "Safety on" Signal output "Error"
Post-box 1111 D-73277 Owen-Teck Tel. ++49 7021 5730
– 912 –
TNT 35 - 01
Page 913
Page 914
Leuze electronic TNT 35
Test monitoring unit Dimensioned drawing
Electrical connection
TÜV Baumuster
24 V DC
BWS Typ 2
We reserve the right to make changes • SLS_s08e.fm l High security through permanent cyclic test in time intervals of 2 sec. l Highest operating safety through microcontroller technique l Security relay output with fault protected monitoring l No interruption of operation during test procedure l Connection possibility for all current testable protective photoelectric sensors l Optical coupler inputs for high interference protection l Separate signalling outputs as PNP transistor outputs l Selectable start and restart-disable
ISO 9001
IEC 60947...
Accessories:
A B C D E
F G H I J K L
Leuze electronic GmbH + Co. http://www.leuze.de
Transmitter Receiver Operation with start/restart-disable Operation without start/restart-disable Selection of the operating mode by bridging: terminal 22 and 23 (with start/restart-disable) or terminal 23 and 24 (without start/restart-disable) Factory setting for the bridge is between terminals 23 and 24 (with start/restart-disable function) EDM (contactor monitoring, feedback control loop) Safety relay output 2 EMERGENCY SHUTDOWN Safety relay output 1 Signal output "Safety" Signal output "Error"
Post-box 1111 D-73277 Owen-Teck Tel. ++49 7021 5730
– 914 –
TNT 35/7-24V - 01
Page 915
Page 916
Leuze electronic TMC 66
Test monitoring unit Dimensioned drawing
Electrical connection
TÜV Baumuster
24 V DC
BWS Typ 2
We reserve the right to make changes • SLS_s04e.fm l High security through permanent cyclic test in time intervals of 2 sec. l Security relay output with fault protected monitoring l No interruption of operation during test procedure l Connection possibility for all current testable protective photoelectric sensors l Selectable start and restart-disable and contactor control l Processing of PLC control signals as muting sender l Integrated muting function l Connection for two monitored muting warning lights (necessary acc. to EN 61496-1) l Integrated self-containing mode (start with dimmed AOPD) l Separate signalling outputs as PNP transistor outputs
ISO 9001
IEC 60947...
Accessories: (available separately)
l Testable muting sender - suitable: - PRK 96 K/P-1361-29 (Part No. 500 80476) - PRK 97/4.8 L (Part No. 500 80474) - IPRK 92/4.8 S (Part No. 500 14199) - PRK 46/4.8-S12 (Part No. 500 60920) l all throughbeam photoelectric sensors with (.8) activation input Leuze electronic GmbH + Co. http://www.leuze.de
A SLS transmitter active B SLS receiver C Start D Relay monitoring E Signal output "Error" F Signal output "Safety on" G Output Test H Start 1 I Input J Start 2 K Indicator diodes L Safety relay output 2 M Safety relay output 1 N Muting lamp 1 O Muting lamp 2 P start/restart-disable Status 1 Test monitoring unit - SLS Status 2 Muting controller
Post-box 1111 D-73277 Owen-Teck Tel. ++49 7021 5730
– 916 –
TMC 66 - 02