Browse
(440) 299-7778
Menu
(440) 299-7778
One-year parts and labor warranty30-day money-back guaranteeEnglishEspañolContact

The text of a manual · part 90 of 105

Catalog: Optical electronic sensors: Explosion Protection, pages 868 to 876

Pages 868 to 876 of 1000, from Catalog: Optical electronic sensors

The original document is the PDF (46 MB). This is its text as extracted, unedited; tables and drawings read best in the PDF, and each page heading opens it at that page.

For the Leuze FRK 92, Leuze PRK406 and Leuze PRK 3

Page 868

Leuze electronic FRK 92 Ex

Diffuse reflection light scanner with background suppression Dimensioned drawing

0.03 … 0.3m 5,5 - 14 V DC

We reserve the right to make changes • 92x_d01e.fm l Compact construction with robust diecast zinc housing and glass optics for protection against environmental influences l Switching output acc. to DIN 19234 (NAMUR) l In accordance with the directives of BG-Chemie l Conformity certificate - BVS 97.D.2071 l EEx ia IIC T6

ISO 9001

IEC 60947...

A Scanning range adjustment B Indicator diode C Optical axis Preferred entry direction for objects € + ó + ì

Electrical connection IP 67

IEC 60947...

Accessories: (available separately • see page 874)

l Mounting systems (BT 92, UMS 1) l M12 connectors (KD …) l Isolated switching amplifier

Leuze electronic GmbH + Co. http://www.leuze.de

Post-box 1111 D-73277 Owen-Teck Tel. ++49 7021 5730

– 868 –

FRK 92…Ex - 02

Page 869

The text of this page cannot be shown here; see it in the PDF.

Page 870

Leuze electronic VS 401

Isolated switching amplifier Dimensioned drawing

18 - 35 V DC

We reserve the right to make changes • 92x_v01e.fm l Intrinsically safe input [EEx ia] IIC l Input, output and operating voltage are galvanically isolated l Wire break/short circuit monitoring l Operating modes adjustable l Switching output with relay or transistor (NPN) l 1 channel l EMC according to NAMUR NE 21 l Top hat rail mounting l Conformity certificate BVS 95.D.2093X

ISO 9001

Connection terminals: operating voltage and switching output LED 2: operating voltage Switch for setting the operating modes Connection terminals: input [EEx ia] IIC Label area Switching state and wire break/short-circuit

Electrical connection potentially explosive area

NAMUR DIN 19 234

A B C D E F area without danger of explosions

IEC 1000...

Accessories:

Leuze electronic GmbH + Co. http://www.leuze.de

Post-box 1111 D-73277 Owen-Teck Tel. ++49 7021 5730

– 870 –

VS 401/R - 03 VS 401/N - 03

Page 871

The text of this page cannot be shown here; see it in the PDF.

Page 872

Leuze electronic VS 401

Isolated switching amplifier Dimensioned drawing

190-255 V AC

We reserve the right to make changes • 92x_v02e.fm l Intrinsically safe input [EEx ia] IIC l Input, output and operating voltage are galvanically isolated l Wire break monitoring (may be deactivated) l Operating modes adjustable l Switching output with relay l 1 channel l EMC according to NAMUR NE 21 l Top hat rail mounting l Conformity certificate PTB Ex-89.C.2025

ISO 9001

Connection terminals: operating voltage and switching output LED 2: wire break Switch for setting the operating modes Connection terminals: input [EEx ia] IIC Label area switching state

Electrical connection potentially explosive area

NAMUR DIN 19 234

A B C D E F area without danger of explosions

IEC 1000...

Accessories:

Leuze electronic GmbH + Co. http://www.leuze.de

Post-box 1111 D-73277 Owen-Teck Tel. ++49 7021 5730

– 872 –

VS 401/R-AC - 03

Page 873

The text of this page cannot be shown here; see it in the PDF.

Page 874

Accessories

Leuze electronic

92 Series Ex

Accessories

We reserve the right to make changes • 92x_zu_e.fm

Additional information in section "Accessories" from page 925 onwards!

Reflectors

Dimensioned drawings l Reflectors and reflective tapes are ideally suited for Leuze retro-reflective photoelectric sensors. The performance data refer to the use of Leuze reflectors and reflective tapes. The range of retro-reflective photoelectric sensors depends on the type and size of the reflector. l Adhesive and screw type versions permit universal installation. l Precise optical alignment is not required, as the reflector may be slightly inclined relative to the optical axis. l For retro-reflective photoelectric sensors with polarisation filters, only triad-type reflectors made of plastic or reflective tapes No 2 and No 3 may be used.

Order codes:

Tape No. 2

Selection table

Designation

Part No.

TKS 100x100 TK 100x100 TKS 50x100 TK 50x100 MTKS 50x50 TKS 50x50 TKS 30x50 TK 30x50 TK 82 TK 60 TK 45 Tape 2 KB 092-5000-4 Ex KB 092-5000-4A Ex KD 095-5 KD 095-5A BT 92 UMS 1 VS 401/N VS 401/R VS 401/R-AC

500 22816 500 03192 500 22815 500 03191 500 36188 500 22814 500 23525 500 03189 500 03187 500 03186 500 03185 500 11523 500 37784 500 37783 500 20502 500 20501 500 18415 500 22281 500 30426 500 30427 500 30428

Leuze electronic GmbH + Co. http://www.leuze.de

Designation

Temp. range

Dimensions [mm]

TKS 100x100 TK 100x100 TKS 50x100 TK 50x100 MTKS 50x50 TKS 50x50 TKS 30x50 TK 30x50 TK 82 TK 60 TK 45 Tape 2

-20°C/+60°C -20°C/+60°C -20°C/+60°C -20°C/+60°C -20°C/+60°C -20°C/+60°C -20°C/+60°C -20°C/+60°C -20°C/+60°C -20°C/+60°C -20°C/+60°C -20°C/+60°C

124.6 100 99 99 124.6 53.5 99 49.5 51 60.7 75 53.6 75 34.5 48 32 84 9 64 8 46 8 100 100 a 2) 2)

2) 1)

3)

b

Fastening c screw type

9.5 9 9.5 9 7 9.5 9.5 6.8 l m l m l l l m l l adhesive l l l l l

1) heating capability (HTK 82) 2) for screw mounting use mounting bracket 3) available as sheet 914x749

Post-box 1111 D-73277 Owen-Teck Tel. ++49 7021 5730

– 874 –

Accessories 92 Series Ex - 02

Page 875

Leuze electronic 92 Series Ex Selection table

Connectors, plugs, cables

Ready-made cables with 4-pin M12 connector 5m cable length Sensor designation

Cable designation (Part No.)

LS 92/3 Ex KB 092-5000-4 Ex (Part No. 500 37784)

PRK 92/3 L Ex FRK 92/3-3000 L Ex

M12 connectors with cable (5m cable length) KB 092-5000-4 Ex KB 092-5000-4AEx

For the intrinsically safe devices of the 92 Ex Series, Leuze electronic offers plugs with ready-made blue cables of 5m length. without cable

KD 095-5

KD 095-5A

These blue cables have to be used in Ex zones 0 or 1 for intrinsically safe circuits. For devices with M12 connectors, there are available: 2 connectors with ready-made 5m cable and 2 connectors with screw connection. When ordering throughbeam photoelectric sensors, keep in mind that a connector is required both for the transmitter and receiver.

Dimensioned drawings BT 92

Mounting systems BT 92

UMS 1

UMS 1

Accessories 92 Series Ex - 02

0202

– 875 –

Page 876

Leuze electronic

Leuze electronic GmbH + Co. http://www.leuze.de

Post-box 1111 D-73277 Owen-Teck Tel. ++49 7021 5730

– 876 –