The text of a manual · part 83 of 105
Catalog: Optical electronic sensors: Measuring Sensors, pages 803 to 808
Pages 803 to 808 of 1000, from Catalog: Optical electronic sensors
The original document is the PDF (46 MB). This is its text as extracted, unedited; tables and drawings read best in the PDF, and each page heading opens it at that page.
For the Leuze FRK 92, Leuze PRK406 and Leuze PRK 3
Page 803
Page 804
Leuze electronic ODS 96
Optical laser distance sensors Dimensioned drawing
200 … 2000mm 10 - 30 V DC l Reflection-independent distance information l Highly insensitive to extraneous light l Measurement range and mode adjustable l Two teachable switching outputs
We reserve the right to make changes • ods_05e.fm
ISO 9001
IEC 60947...
A B C D E F G H I K L
Indicator diode green Indicator diode yellow Transmitter Receiver Optical axis Device plug M12x1 Screwed cable gland PG11 for Ø5 … 10mm Countersinking for SK nut M5, 4.2mm deep Parameter plug Connection terminals Cable entry
Electrical connection IP 67
IEC 60947...
Accessories: (available separately • see page 808)
l Mounting systems l Programming software
Leuze electronic GmbH + Co. http://www.leuze.de
Post-box 1111 D-73277 Owen-Teck Tel. ++49 7021 5730
– 804 –
ODS 96M/S… Laser - 03
Page 805
Page 806
Leuze electronic rotoScan ROD-4
Optical distance sensors Dimensioned drawing 122
Ø 5.2
Ø 5.2
0 … 15m 24 V DC l The rotoScan ROD-4 is an area scanning distance sensor for the detection of objects. The light beam is reflected by a rotating mirror and directed over a semicircular area (190°) with a radius of max. 50m. l The area is divided into two detection areas, each with a radius of 15m. The size of the area to be evaluated can be freely defined in each detection area. l It is possible to store 4 detection area pairs in the ROD-4 and to switch between these pairs, for example, to define various heights or allowed overhangings.
Ø 5.2
Ø 5.2
130 140.12
Measurement principle 528 sectors, 0.36° each 190° working range
We reserve the right to make changes • ods_10e.fm
ISO 9001
IEC 60947...
IP 67
IEC 60947...
Accessories: (available separately • see page 808)
l Mounting systems l Programming software l Various connection cables
Working field (50m) Detection area 1 (max. 15m) Detection area 2 (max. 15m)
Leuze electronic GmbH + Co. http://www.leuze.de
Post-box 1111 D-73277 Owen-Teck Tel. ++49 7021 5730
– 806 – rotoScan ROD-4 - 01
Page 807
Leuze electronic rotoScan ROD-4 Specifications
Tables
Optical data Scanning range (per detection area) Angular range Angular resolution Scanning rate Transmitter with infrared laser diode
0 … 15m max. 190° 0.36° 25 scans/s or 40ms/scan laser safety class 1 (eye safe), wavelength = 905nm beam divergence = 2mrad time base = 100s
Detection area 1 and 2 Reflectivity Object size from min. 1.8% (flat black) > 20mm at distance of 4m > 100mm at distance of 15m Response time at least 80ms (corresponds to 2scans) Number of detection area pairs 4 (selectable via switching inputs) Output 3 x PNP transistor output 24V/250mA Measurement value resolution per sector 5mm Repeatability 10…90% diffuse reflection at 4m distance ± 15mm
Electrical data Voltage supply Overcurrent protection Current consumption Power consumption Overvoltage protection
+24VDC +20%/-30% via fuse 2A semi time-lag in the switching cabinet approx. 400mA (use 1A power supply), approx. 1A with heating < 60W at 24V including the outputs overvoltage protection with protected limit stop
Mechanical data Housing Weight Connection type diecast aluminium, plastic 3.6kg 2 connectors (can be plugged from above, solder connection)
Environmental data Ambient temp. (operation/storage) VDE safety class Protection class Standards applied
-0°C … +50°C/-20°C … +60 C -20°C … +50°C/-20°C … +60 C (with heating) II, all-insulated IP 65 IEC 60947-5-2
Operating principle
Received light Object
Remarks "RODsoft" configuration software The configuration software "RODsoft" runs under Windows 95/98/NT/2000 and offers the following possibilities: l Programming of the detection areas l Parameterisation of other data l Visualisation of the detection area with measurement values l Error code display l Support of various languages There are various methods with which detection areas can be programmed, for example: l "Teach-in" function l Numerical and graphical entry of the detection areas l "Edit" function
Transmitted beam B A
Order guide
With heating
Designation
Part No.
C
ROD-4 ROD-4-06
500 36010 500 38614
A Detection area 1 B Detection area 2 C Current measurement values rotoScan ROD-4 - 01
C
0202
– 807 –
Page 808
Accessories
Leuze electronic
Accessories
ODS
M12 connectors
Dimensioned drawings
For devices with M12 connectors, there are available: 2 connectors with ready-made 5m cable and 2 connectors with screw connection.
Additional information in section "Accessories" from page 925 onwards!
Protection class (DIN 40050) plugged and screwed: IP 67 Important: With throughbeam photoelectric sensors, a connector is required both for the transmitter and the receiver.
Selection table M12 connectors with cable (5m) 5-pin without cable
KB 095-5000-5
KB 095-5000-5A
KD 095-5
KD 095-5A
Part No. 500 20500
Part No. 500 20499
Part No. 500 20502
Part No. 500 20501
Mounting systems
Dimensioned drawings
BT 96 (Part No. 500 25570)
BT 96
UMS 96
We reserve the right to make changes • ods_zu_e.fm
UMS 96 (Part No. 500 26204)
KB-ODS 96-1500 (Part No. 500 82007)
A Leuze electronic GmbH + Co. http://www.leuze.de for screw M5
Post-box 1111 D-73277 Owen-Teck Tel. ++49 7021 5730
– 808 –
Accessories ODS - 02