Page 713
Leuze electronic LVSR 8 Teach-in Step switch
Scanner operation
Throughbeam operation
LED green
LED yellow
Normal operation
Run
Operating position
Operating position
ON
Q
Activated
Run -> Teach
Immediately
Immediately
OFF
OFF
Time lock
Teach
> 2s
> 2s
3Hz
OFF
Teaching phase 1
Teach
Accept value 1 (background) Accept value 1 (free light path)
3Hz
OFF
Teaching phase 2
Teach -> Run
Accept value 2 (object)
Accept value 2 (object)
3Hz
OFF
Normal operation
Run
Operating position
Operating position
ON
Q
The step switch must be set to >500ms to allow the individual functions to be activated.
Changing the switching threshold Step switch
Scanner operation
Throughbeam operation
LED green
LED yellow
Normal operation
Run
Operating position
Operating position
ON
Q
Activated
Run -> (+/-)
Immediately
Immediately
OFF
OFF
Time lock
(+/-)
> 2s
> 2s
1Hz
Q
Change
(+/-)
Switching threshold (increase/decrease)
Switching threshold (increase/decrease)
1Hz
Q
Normal operation
(+/-) -> Run
Operating position
Operating position
ON
Q
At switch position (+/-), the switching threshold is increased by 5% every second. Maximum value LED green = ON Minimum value LED green = OFF
Pulse stretching on/off Step switch
Scanner operation
Throughbeam operation
LED green
LED yellow
Normal operation
Run
Operating position
Operating position
ON
Q
Activated
Run -> Delay
Immediately
Immediately
OFF
OFF
Time lock
Delay
> 2s
> 2s
10Hz
Status
Change
Delay
> 10s pulse stretching on <-> off
Pulse stretching On <-> Off
10Hz
New
Normal operation
Delay -> Run
Operating position
Operating position
ON
Q
LSVR 8/24 … - 01
0202
– 713 –
Page 714
Leuze electronic Glass fibre optic cables Dimensioned drawing
1000mm
80mm
GLL
We reserve the right to make changes • LSG_e08e.fm l Glass fibre optic cables in throughbeam or scanner operation l Fibre optic cables with various cross sections and end pieces l Connection pieces suitable for all control devices of the series (I)LVS 19, (I)LVS 9, LVSR 8 and LVSR 325 l Metal sheathing allows use at high temperatures and offers the maximum mechanical fibre protection l Silicone coated metal sheathing results in a high protection class (IP 65) and allows use in the food industry
Accessories: (available separately)
l Angles and optics attachments l GF-L1 (Part No. 500 14649) l GF-U1 (Part No. 500 09382)
A B C Leuze electronic GmbH + Co. http://www.leuze.de
Active diameter At VA sheathing Ø8mm Waveguide
Post-box 1111 D-73277 Owen-Teck Tel. ++49 7021 5730
– 714 –
Glass fibre optic cables - 03
Page 715
Leuze electronic Glass fibre optic cables Specifications
Remarks
Optical data Standard length Fibre optic cable outer diameter Minimum bending radius Materials of sheathing and end piece …-MS …-SI …-VA Operation and storage temperature …-MS …-SI …-VA approx. 500mm and approx. 1000mm (special lengths on request) approx. 5mm 40mm brass/aluminium anodised or V2A silicone/V2A V2A/V2A -30°C … +140°C -30°C … +160°C -30°C … +300°C (transient)
Order guide Glass fibre optic cable in throughbeam operation Designation Operating range 1) Operating range 2) Operating range 3) With GF-L1 1) With GF-U1 1) Active light beam diameter [mm]
GF 500/1 LS-… GF 1000/1 LS-… 200mm 250mm 250mm 400mm 700mm 1.1mm
GF 500/4 LS-…
GF 1000/4 LS-…
600mm 300mm 600mm 300mm 500mm 2.3mm
1000mm 300mm 600mm 300mm 700mm 2.3mm
1) Operating range in connection with (I)LVS 9/… and (I)LVS 19/… 2) Operating range in connection with LVSR 325 3) Operating range in connection with LVSR 8
Example code:
GF 500/1 LS-MS brass jacket throughbeam operation small active light beam diameter approx. 1mm fibre length approx. 500mm glass fibre l Mounting When mounting the fibre optic cable, a minimum bending radius of 40mm must be guaranteed for reliable function. l Connection The fibre optic cables must be inserted securely into the corresponding openings in the control device. The fibre optic cable is fixed in place using the set screw. l Optical attachments For larger operating ranges using …/1 type cable (beam exit approx. 1mm), or changes in cable direction, optical attachments are available. Attention: When mounting attachments, ensure that the optics are not contaminated by adhesive substances. The adhesive must fulfil the temperature requirements. l Shipment is done in pairs for throughbeam (LS) applications. l Fibre optic cables with other lengths, head pieces and cross sections on request.
Glass fibre optic cables in scanner operation Designation Scanning range 1) Scanning range 2) Scanning range 3) Active light beam diameter [mm]
GF 500/1 RT-… GF 1000/1 RT-… 50mm 50mm 50mm 1.8mm
GF 500/4 RT-… GF 1000/4 RT-… 80mm 80mm 80mm 3.5mm
GF 1000/1 RT-MS.1 10mm 10mm 0.5mm
1) Scanning range in connection with (I)LVS 9/… and (I)LVS 19/… relative to white 90% 2) Scanning range in connection with LVSR 325 relative to white 90% 3) Scanning range in connection with LVSR 8 relative to white 90%
Example code:
GF 1000/4 RT-SI silicone jacket scanner operation large active light beam diameter approx. 4mm fibre length approx. 1000mm glass fibre
Glass fibre optic cables - 03
0202
– 715 –
Page 716
Leuze electronic Special types
Glass fibre optic cables Dimensioned drawing
1000mm
80mm
GLL
We reserve the right to make changes • LSG_e08e.fm l Glass fibre optic cables in throughbeam or scanner operation l Fibre optic cables with various cross sections and end pieces l Connection pieces suitable for all control devices of the series (I)LVS 19, (I)LVS 9, LVSR 8 and LVSR 325 l Silicone coated metal sheathing results in a high protection class (IP 65) and allows use in the food industry
Accessories: (available separately)
Leuze electronic GmbH + Co. http://www.leuze.de
Post-box 1111 D-73277 Owen-Teck Tel. ++49 7021 5730
– 716 –
Page 717
Leuze electronic Glass fibre optic cables Order guide
Remarks
Glass fibre optic cables in throughbeam operation l Fibre optic cables with other lengths, head pieces and cross sections on request.
l l l
GF 1000/4 LS-VA Part No. 500 00045
GF 1000/4 LS-SI Part No. 500 00037
GF 1000/4 LS-MS Part No. 500 01033
GF 500/4 LS-VA Part No. 500 00043 l l l l l l l l l l l
GF 1000/4 RT-MS.1 Part No. 500 11508 l l l l
GF 1000/4 RT-SI Part No. 500 00041 l l
GF 1000/4 RT-MS Part No. 500 01037 l l l
GF 500/4 RT-VA Part No. 500 00047 l
GF 500/4 LS-MS Part No. 500 01031
GF 1000/1 LS-SI Part No. 500 00036 l l
GF 500/4 RT-MS Part No. 500 01035
Light beam diameter l
GF 1000/1 RT-MS Part No. 500 01036
Length brass/aluminium silicone/V2A V2A/V2A 500mm 1000mm approx. 1mm approx. 4mm
GF 1000/1 LS-MS Part No. 500 01032
Equipment Ï Sheathing/end piece
GF 500/1 LS-SI Part No. 500 06779
Order code Í
GF 500/1 LS-MS Part No. 500 01030
Selection table l l
Glass fibre optic cables in scanner operation
Length Light beam diameter brass/aluminium silicone/V2A V2A/V2A 500mm 1000mm approx. 1mm approx. 4mm
GF 500/1 RT-VA Part No. 500 00046
Equipment Ï Sheathing/end piece
GF 500/1 RT-SI Part No. 500 00038
Order code Í
GF 500/1 RT-MS Part No. 500 01034
Selection table l l l l l l l l l l l l l l l l l l l l l l l l l
Special types - Glass fibre optic cables in throughbeam or scanner operation
Sheathing/end piece
Length Light beam diameter throughbeam operation scanner operation brass/aluminium silicone/V2A V2A/V2A 600mm approx. 1mm approx. 4mm l l l l l
GF 600/4-RT-SI-W Part No. 500 34367
GF 600/4-LS-SI-W Part No. 500 34359
GF 600/4-RT-SI-M4 Part No. 500 34356
GF 600/4-LS-SI-M4 Part No. 500 34361
GF 600/1-RT-SI-W-1,5 Part No. 500 34368
GF 600/1-LS-SI-W-1,5 Part No. 500 34363
Equipment Ï Operating mode
GF 600/1-RT-SI-1,5 Part No. 500 34352
Order code Í
GF 600/1-LS-SI-1,5 Part No. 500 34365
Selection table l l l l l l l l l l l l l l l l l l l l l l l l l l l
Glass fibre optic cables - 03
0202
– 717 –
Page 718
Leuze electronic Plastic fibre optic cables in throughbeam operation Dimensioned drawing
200mm
KLL
We reserve the right to make changes • LSG_e09e.fm l Plastic fibre optic cables in throughbeam operation l Fibre optic cables with various cross sections and end pieces l Length can be cut by the user l Connection pieces suitable for fibre optic cable amplifiers LVS 420/P, LVSR 8 and LVSR 325 l With ".5" versions, the end piece is bendable and can be adjusted to every mounting position
Accessories: (available separately)
l Angles and optics attachments - KF-L1 (Part No. 500 34065) - KF-U1 (Part No. 500 34064) (part of the delivery contents)
l Fibre optic cable cutting device (except for KF 2000/2 LS.4-08) l Adapter (for fibre optic cables with Ø1mm)
Leuze electronic GmbH + Co. http://www.leuze.de
Post-box 1111 D-73277 Owen-Teck Tel. ++49 7021 5730
– 718 –
Plastic fibre optic cables - 04
Page 719
Leuze electronic Plastic fibre optic cables in throughbeam operation Specifications
Remarks
Optical data Standard length Reinforcement Operating temperature Minimum bending radius
2000mm PVC -25°C … +80°C 15mm
Order guide Plastic fibre optic cables in throughbeam operation Order code
KF 2000/2 LS.4-01 Part No. 500 22775 KF 2000/2 LS.4-08 Part No. 500 35309
Operating range 1) Operating range 2) Operating range 3) Fibre optic cable outer diameter
80mm 200mm 200mm 2mm
KF-L1 KF-U1 800mm 100mm 2500mm 250mm 2000mm 200mm
KF 2000/2 LS.4-02 Part No. 500 27780
KF 2000/2 LS.5-03 Part No. 500 27781
100mm 200mm 200mm 2mm
100mm 200mm 200mm 2mm l Mounting When mounting the fibre optic cable, a minimum bending radius of 15mm must be guaranteed for reliable function. Moreover, the fibre optic cable must not be bent within 15mm of the sensor and cable head. The minimum bending radius of the stainless steel sleeve on the cable head is 10mm. l Connection The fibre optic cables must be inserted securely into the corresponding openings in the control device (connection length approx. 15mm). The fastening screw is used for fixation of the fibre optic cables. l Cutting The plastic fibre optic cable can be cut to the desired length using the fibre optic cable cutting device. Each cut opening may only be used once. l Adapter The included adapter must be used with fibre optic cables having a fibre diameter of 1mm. The fibre optic cable must extend more than 0.5mm beyond the adapter. l First installation Before using the fibre optic cable for the first time, the fibre must be cut at the end to provide a smooth surface. l Optical attachments Screw-on type for KF 2000/2 LS.4-01 (throughbeam operation). With optical attachment KF-L1 for longer operating ranges. With optical attachment KF-U1 for 90° deflection. Operating range see table. l Shipment is done in pairs for throughbeam (LS) applications.
1) Operating range in connection with LVS 420/P 2) Operating range in connection with LVSR 325 3) Operating range in connection with LVSR 8
Plastic fibre optic cables - 04
0202
– 719 –
Page 720
Leuze electronic Plastic fibre optic cables in scanner operation Dimensioned drawing
80mm
KLL
We reserve the right to make changes • LSG_e09e.fm l Plastic fibre optic cables in scanner operation l Fibre optic cables with various cross sections and end pieces l Length can be cut by the user l Connection pieces suitable for fibre optic cable amplifiers LVS 420/P, LVSR and LVSR 325 l With ".5" versions, the end piece is bendable and can be adjusted to every mounting position
Accessories: (part of the delivery contents)
l Fibre optic cable cutting device l Adapter (for fibre optic cables with Ø1mm)
Leuze electronic GmbH + Co. http://www.leuze.de
Post-box 1111 D-73277 Owen-Teck Tel. ++49 7021 5730
– 720 –
Page 721
Leuze electronic Plastic fibre optic cables in scanner operation Specifications
Remarks l Mounting When mounting the fibre optic cable, a minimum bending radius of 15mm must be guaranteed for reliable function. Moreover, the fibre optic cable must not be bent within 15mm of the sensor and cable head. The minimum bending radius of the stainless steel sleeve on the cable head is 10mm. l Connection The fibre optic cables must be inserted securely into the corresponding openings in the control device (connection length approx. 15mm). The fastening screw is used for fixation of the fibre optic cables. l Cutting The plastic fibre optic cable can be cut to the desired length using the fibre optic cable cutting device. Each cut opening may only be used once. l Adapter The included adapter must be used with fibre optic cables having a fibre diameter of 1mm. The fibre optic cable must extend more than 0.5mm beyond the adapter. l First installation Before using the fibre optic cable for the first time, the fibre must be cut at the end to provide a smooth surface. l Shipment is done in pairs for throughbeam (LS) applications.
Optical data Standard length Reinforcement Operating temperature Minimum bending radius
2000mm PVC -25°C … +80°C 15mm
Order guide Plastic fibre optic cable in scanner operation Order code
KF 2000/2 RT.4-04 KF 2000/2 RT.4-05 Part No. 500 27782 Part No. 500 27783
Scanning range 1) 25mm Scanning range 2) 65mm Scanning range 3) 50mm Fibre optic cable 2mm outer diameter
30mm 80mm 60mm 2mm
KF 2000/1 RT.4-06 Part No. 500 27784
KF 2000/2 RT.5-07 Part No. 500 27785
6mm 15mm 10mm 1mm
30mm 65mm 50mm 2mm
1) Scanning range in connection with LVS 420/P relative to white 90% 2) Scanning range in connection with LVSR 325 relative to white 90% 3) Scanning range in connection with LVSR 8 relative to white 90%
Plastic fibre optic cables - 04
0202
– 721 –
Page 722
Leuze electronic
Leuze electronic GmbH + Co. http://www.leuze.de
Post-box 1111 D-73277 Owen-Teck Tel. ++49 7021 5730