Page 713

Leuze electronic LVSR 8 Teach-in Step switch

Scanner operation

Throughbeam operation

LED green

LED yellow

Normal operation

Run

Operating position

Operating position

ON

Q

Activated

Run -> Teach

Immediately

Immediately

OFF

OFF

Time lock

Teach

> 2s

> 2s

3Hz

OFF

Teaching phase 1

Teach

Accept value 1 (background) Accept value 1 (free light path)

3Hz

OFF

Teaching phase 2

Teach -> Run

Accept value 2 (object)

Accept value 2 (object)

3Hz

OFF

Normal operation

Run

Operating position

Operating position

ON

Q

The step switch must be set to >500ms to allow the individual functions to be activated.

Changing the switching threshold Step switch

Scanner operation

Throughbeam operation

LED green

LED yellow

Normal operation

Run

Operating position

Operating position

ON

Q

Activated

Run -> (+/-)

Immediately

Immediately

OFF

OFF

Time lock

(+/-)

> 2s

> 2s

1Hz

Q

Change

(+/-)

Switching threshold (increase/decrease)

Switching threshold (increase/decrease)

1Hz

Q

Normal operation

(+/-) -> Run

Operating position

Operating position

ON

Q

At switch position (+/-), the switching threshold is increased by 5% every second. Maximum value LED green = ON Minimum value LED green = OFF

Pulse stretching on/off Step switch

Scanner operation

Throughbeam operation

LED green

LED yellow

Normal operation

Run

Operating position

Operating position

ON

Q

Activated

Run -> Delay

Immediately

Immediately

OFF

OFF

Time lock

Delay

> 2s

> 2s

10Hz

Status

Change

Delay

> 10s pulse stretching on <-> off

Pulse stretching On <-> Off

10Hz

New

Normal operation

Delay -> Run

Operating position

Operating position

ON

Q

LSVR 8/24 … - 01

0202

– 713 –

Page 714

Leuze electronic Glass fibre optic cables Dimensioned drawing

1000mm

80mm

GLL

We reserve the right to make changes • LSG_e08e.fm l Glass fibre optic cables in throughbeam or scanner operation l Fibre optic cables with various cross sections and end pieces l Connection pieces suitable for all control devices of the series (I)LVS 19, (I)LVS 9, LVSR 8 and LVSR 325 l Metal sheathing allows use at high temperatures and offers the maximum mechanical fibre protection l Silicone coated metal sheathing results in a high protection class (IP 65) and allows use in the food industry

Accessories: (available separately)

l Angles and optics attachments l GF-L1 (Part No. 500 14649) l GF-U1 (Part No. 500 09382)

A B C Leuze electronic GmbH + Co. http://www.leuze.de

Active diameter At VA sheathing Ø8mm Waveguide

Post-box 1111 D-73277 Owen-Teck Tel. ++49 7021 5730

– 714 –

Glass fibre optic cables - 03

Page 715

Leuze electronic Glass fibre optic cables Specifications

Remarks

Optical data Standard length Fibre optic cable outer diameter Minimum bending radius Materials of sheathing and end piece …-MS …-SI …-VA Operation and storage temperature …-MS …-SI …-VA approx. 500mm and approx. 1000mm (special lengths on request) approx. 5mm 40mm brass/aluminium anodised or V2A silicone/V2A V2A/V2A -30°C … +140°C -30°C … +160°C -30°C … +300°C (transient)

Order guide Glass fibre optic cable in throughbeam operation Designation Operating range 1) Operating range 2) Operating range 3) With GF-L1 1) With GF-U1 1) Active light beam diameter [mm]

GF 500/1 LS-… GF 1000/1 LS-… 200mm 250mm 250mm 400mm 700mm 1.1mm

GF 500/4 LS-…

GF 1000/4 LS-…

600mm 300mm 600mm 300mm 500mm 2.3mm

1000mm 300mm 600mm 300mm 700mm 2.3mm

1) Operating range in connection with (I)LVS 9/… and (I)LVS 19/… 2) Operating range in connection with LVSR 325 3) Operating range in connection with LVSR 8

Example code:

GF 500/1 LS-MS brass jacket throughbeam operation small active light beam diameter approx. 1mm fibre length approx. 500mm glass fibre l Mounting When mounting the fibre optic cable, a minimum bending radius of 40mm must be guaranteed for reliable function. l Connection The fibre optic cables must be inserted securely into the corresponding openings in the control device. The fibre optic cable is fixed in place using the set screw. l Optical attachments For larger operating ranges using …/1 type cable (beam exit approx. 1mm), or changes in cable direction, optical attachments are available. Attention: When mounting attachments, ensure that the optics are not contaminated by adhesive substances. The adhesive must fulfil the temperature requirements. l Shipment is done in pairs for throughbeam (LS) applications. l Fibre optic cables with other lengths, head pieces and cross sections on request.

Glass fibre optic cables in scanner operation Designation Scanning range 1) Scanning range 2) Scanning range 3) Active light beam diameter [mm]

GF 500/1 RT-… GF 1000/1 RT-… 50mm 50mm 50mm 1.8mm

GF 500/4 RT-… GF 1000/4 RT-… 80mm 80mm 80mm 3.5mm

GF 1000/1 RT-MS.1 10mm 10mm 0.5mm

1) Scanning range in connection with (I)LVS 9/… and (I)LVS 19/… relative to white 90% 2) Scanning range in connection with LVSR 325 relative to white 90% 3) Scanning range in connection with LVSR 8 relative to white 90%

Example code:

GF 1000/4 RT-SI silicone jacket scanner operation large active light beam diameter approx. 4mm fibre length approx. 1000mm glass fibre

Glass fibre optic cables - 03

0202

– 715 –

Page 716

Leuze electronic Special types

Glass fibre optic cables Dimensioned drawing

1000mm

80mm

GLL

We reserve the right to make changes • LSG_e08e.fm l Glass fibre optic cables in throughbeam or scanner operation l Fibre optic cables with various cross sections and end pieces l Connection pieces suitable for all control devices of the series (I)LVS 19, (I)LVS 9, LVSR 8 and LVSR 325 l Silicone coated metal sheathing results in a high protection class (IP 65) and allows use in the food industry

Accessories: (available separately)

Leuze electronic GmbH + Co. http://www.leuze.de

Post-box 1111 D-73277 Owen-Teck Tel. ++49 7021 5730

– 716 –

Page 717

Leuze electronic Glass fibre optic cables Order guide

Remarks

Glass fibre optic cables in throughbeam operation l Fibre optic cables with other lengths, head pieces and cross sections on request.

l l l

GF 1000/4 LS-VA Part No. 500 00045

GF 1000/4 LS-SI Part No. 500 00037

GF 1000/4 LS-MS Part No. 500 01033

GF 500/4 LS-VA Part No. 500 00043 l l l l l l l l l l l

GF 1000/4 RT-MS.1 Part No. 500 11508 l l l l

GF 1000/4 RT-SI Part No. 500 00041 l l

GF 1000/4 RT-MS Part No. 500 01037 l l l

GF 500/4 RT-VA Part No. 500 00047 l

GF 500/4 LS-MS Part No. 500 01031

GF 1000/1 LS-SI Part No. 500 00036 l l

GF 500/4 RT-MS Part No. 500 01035

Light beam diameter l

GF 1000/1 RT-MS Part No. 500 01036

Length brass/aluminium silicone/V2A V2A/V2A 500mm 1000mm approx. 1mm approx. 4mm

GF 1000/1 LS-MS Part No. 500 01032

Equipment Ï Sheathing/end piece

GF 500/1 LS-SI Part No. 500 06779

Order code Í

GF 500/1 LS-MS Part No. 500 01030

Selection table l l

Glass fibre optic cables in scanner operation

Length Light beam diameter brass/aluminium silicone/V2A V2A/V2A 500mm 1000mm approx. 1mm approx. 4mm

GF 500/1 RT-VA Part No. 500 00046

Equipment Ï Sheathing/end piece

GF 500/1 RT-SI Part No. 500 00038

Order code Í

GF 500/1 RT-MS Part No. 500 01034

Selection table l l l l l l l l l l l l l l l l l l l l l l l l l

Special types - Glass fibre optic cables in throughbeam or scanner operation

Sheathing/end piece

Length Light beam diameter throughbeam operation scanner operation brass/aluminium silicone/V2A V2A/V2A 600mm approx. 1mm approx. 4mm l l l l l

GF 600/4-RT-SI-W Part No. 500 34367

GF 600/4-LS-SI-W Part No. 500 34359

GF 600/4-RT-SI-M4 Part No. 500 34356

GF 600/4-LS-SI-M4 Part No. 500 34361

GF 600/1-RT-SI-W-1,5 Part No. 500 34368

GF 600/1-LS-SI-W-1,5 Part No. 500 34363

Equipment Ï Operating mode

GF 600/1-RT-SI-1,5 Part No. 500 34352

Order code Í

GF 600/1-LS-SI-1,5 Part No. 500 34365

Selection table l l l l l l l l l l l l l l l l l l l l l l l l l l l

Glass fibre optic cables - 03

0202

– 717 –

Page 718

Leuze electronic Plastic fibre optic cables in throughbeam operation Dimensioned drawing

200mm

KLL

We reserve the right to make changes • LSG_e09e.fm l Plastic fibre optic cables in throughbeam operation l Fibre optic cables with various cross sections and end pieces l Length can be cut by the user l Connection pieces suitable for fibre optic cable amplifiers LVS 420/P, LVSR 8 and LVSR 325 l With ".5" versions, the end piece is bendable and can be adjusted to every mounting position

Accessories: (available separately)

l Angles and optics attachments - KF-L1 (Part No. 500 34065) - KF-U1 (Part No. 500 34064) (part of the delivery contents)

l Fibre optic cable cutting device (except for KF 2000/2 LS.4-08) l Adapter (for fibre optic cables with Ø1mm)

Leuze electronic GmbH + Co. http://www.leuze.de

Post-box 1111 D-73277 Owen-Teck Tel. ++49 7021 5730

– 718 –

Plastic fibre optic cables - 04

Page 719

Leuze electronic Plastic fibre optic cables in throughbeam operation Specifications

Remarks

Optical data Standard length Reinforcement Operating temperature Minimum bending radius

2000mm PVC -25°C … +80°C 15mm

Order guide Plastic fibre optic cables in throughbeam operation Order code

KF 2000/2 LS.4-01 Part No. 500 22775 KF 2000/2 LS.4-08 Part No. 500 35309

Operating range 1) Operating range 2) Operating range 3) Fibre optic cable outer diameter

80mm 200mm 200mm 2mm

KF-L1 KF-U1 800mm 100mm 2500mm 250mm 2000mm 200mm

KF 2000/2 LS.4-02 Part No. 500 27780

KF 2000/2 LS.5-03 Part No. 500 27781

100mm 200mm 200mm 2mm

100mm 200mm 200mm 2mm l Mounting When mounting the fibre optic cable, a minimum bending radius of 15mm must be guaranteed for reliable function. Moreover, the fibre optic cable must not be bent within 15mm of the sensor and cable head. The minimum bending radius of the stainless steel sleeve on the cable head is 10mm. l Connection The fibre optic cables must be inserted securely into the corresponding openings in the control device (connection length approx. 15mm). The fastening screw is used for fixation of the fibre optic cables. l Cutting The plastic fibre optic cable can be cut to the desired length using the fibre optic cable cutting device. Each cut opening may only be used once. l Adapter The included adapter must be used with fibre optic cables having a fibre diameter of 1mm. The fibre optic cable must extend more than 0.5mm beyond the adapter. l First installation Before using the fibre optic cable for the first time, the fibre must be cut at the end to provide a smooth surface. l Optical attachments Screw-on type for KF 2000/2 LS.4-01 (throughbeam operation). With optical attachment KF-L1 for longer operating ranges. With optical attachment KF-U1 for 90° deflection. Operating range see table. l Shipment is done in pairs for throughbeam (LS) applications.

1) Operating range in connection with LVS 420/P 2) Operating range in connection with LVSR 325 3) Operating range in connection with LVSR 8

Plastic fibre optic cables - 04

0202

– 719 –

Page 720

Leuze electronic Plastic fibre optic cables in scanner operation Dimensioned drawing

80mm

KLL

We reserve the right to make changes • LSG_e09e.fm l Plastic fibre optic cables in scanner operation l Fibre optic cables with various cross sections and end pieces l Length can be cut by the user l Connection pieces suitable for fibre optic cable amplifiers LVS 420/P, LVSR and LVSR 325 l With ".5" versions, the end piece is bendable and can be adjusted to every mounting position

Accessories: (part of the delivery contents)

l Fibre optic cable cutting device l Adapter (for fibre optic cables with Ø1mm)

Leuze electronic GmbH + Co. http://www.leuze.de

Post-box 1111 D-73277 Owen-Teck Tel. ++49 7021 5730

– 720 –

Page 721

Leuze electronic Plastic fibre optic cables in scanner operation Specifications

Remarks l Mounting When mounting the fibre optic cable, a minimum bending radius of 15mm must be guaranteed for reliable function. Moreover, the fibre optic cable must not be bent within 15mm of the sensor and cable head. The minimum bending radius of the stainless steel sleeve on the cable head is 10mm. l Connection The fibre optic cables must be inserted securely into the corresponding openings in the control device (connection length approx. 15mm). The fastening screw is used for fixation of the fibre optic cables. l Cutting The plastic fibre optic cable can be cut to the desired length using the fibre optic cable cutting device. Each cut opening may only be used once. l Adapter The included adapter must be used with fibre optic cables having a fibre diameter of 1mm. The fibre optic cable must extend more than 0.5mm beyond the adapter. l First installation Before using the fibre optic cable for the first time, the fibre must be cut at the end to provide a smooth surface. l Shipment is done in pairs for throughbeam (LS) applications.

Optical data Standard length Reinforcement Operating temperature Minimum bending radius

2000mm PVC -25°C … +80°C 15mm

Order guide Plastic fibre optic cable in scanner operation Order code

KF 2000/2 RT.4-04 KF 2000/2 RT.4-05 Part No. 500 27782 Part No. 500 27783

Scanning range 1) 25mm Scanning range 2) 65mm Scanning range 3) 50mm Fibre optic cable 2mm outer diameter

30mm 80mm 60mm 2mm

KF 2000/1 RT.4-06 Part No. 500 27784

KF 2000/2 RT.5-07 Part No. 500 27785

6mm 15mm 10mm 1mm

30mm 65mm 50mm 2mm

1) Scanning range in connection with LVS 420/P relative to white 90% 2) Scanning range in connection with LVSR 325 relative to white 90% 3) Scanning range in connection with LVSR 8 relative to white 90%

Plastic fibre optic cables - 04