Catalog: Optical electronic sensors: Cylindrical Series – Mini photoelectric sensors – Fibre optic devices, pages 683 to 692
Pages 683 to 692 of 1000, from Catalog: Optical electronic sensors
The original document is the PDF (46 MB). This is its text as extracted, unedited; tables and drawings read best in the PDF, and each page heading opens it at that page.
For the Leuze FRK 92, Leuze PRK406 and Leuze PRK 3
Page 683
Page 684
Leuze electronic VS 725
Amplifier Dimensioned drawing
24 V
230 V
DC
AC l Dynamic amplifier for connection of all mini photoelectric sensors (GaAs) for detection of fast events l Sensitivity adjustment for optimum adaptation to the optical or mechanical situation l Automatic contamination compensation l Outputs are short-circuit proof and polarity reversal protected, thus guaranteeing riskless mounting l Easy alignment of the photoelectric sensors through connectable alignment mode and additional LED indicator
We reserve the right to make changes • MS_v15e.fm
A B C
ISO 9001
IEC 60947...
Operating mode Indicator diode Sensitivity adjustment
Electrical connection IP 40
IEC 60947...
Shield
Accessories:
Shield
(available separately)
l Mini photoelectric sensor (see page 638) - LS 725 SE, 20000 (Part No. 500 00270) - LS 725 E, 5000 (Part No. 500 00271)
Leuze electronic GmbH + Co. http://www.leuze.de
Post-box 1111 D-73277 Owen-Teck Tel. ++49 7021 5730
– 684 –
VS 725/4 - 02
Page 685
Page 686
Leuze electronic VS 725
Description of functions
Description of functions and application notes for functional units LS 725 and VS 725/(4) Description of functions The photoelectric sensor amplifiers VS 725 and VS 725/4 are dynamic switching amplifiers. All Leuze infrared mini photoelectric sensors can be operated with these amplifiers, which provide special advantages for the use with throughbeam and retro-reflective photoelectric sensors. Very fast minor changes in light conditions, as well as significant light/dark transitions are detected through the dynamic switching behaviour. It is therefore possible to detect objects which are significantly smaller than the lens area (=active light channel) of the used photoelectric sensors. A darkening which remains for at least 4ms causes an output pulse of 200ms in length. By using the sensitivity potentiometer, the system is adjusted to the conditions given by the application. Fast, small area darkening - high sensitivity. Slow, large area darkening - low sensitivity.
Commissioning First, mechanically align the photoelectric sensor, transmitter and receiver to each other. Connect wired unit to voltage and switch the amplifier to "Alignment". The indicator LED on the receiver then works in analogue mode. Conduct the alignment between transmitter and receiver in such a way that the indicator LED illuminates with maximum brightness. In switch position: "Operation" the unit is switched to the operating state.
Application examples 1. Application area of textile machines For detection of falling rovings, threads, yarns etc. e.g. on flyer, finniseur, drawing frames etc. The light beam is lead alongside the warp in such a way that a breaking thread or thread end falls or swings through the light beam. With the flyer, the following mounting positions are possible
Photoelectric sensor allocation: Lead-in control The axis of the light beam is to be positioned in such a way that a broken strand crosses the light beam.
feed-in to stretching stretched strand runout
With emptying canisters, the remaining stretched strand run-out swings through the photoelectric sensor range and causes a machine standstill.
Leuze electronic GmbH + Co. http://www.leuze.de
Post-box 1111 D-73277 Owen-Teck Tel. ++49 7021 5730
– 686 –
VS 725/4 - 02
Page 687
Leuze electronic VS 725 2. Adhesive joint detection On detection of the adhesive joint, the machine is regulated back to initial speed.
3. Counting of small parts Application of LS 725 at the end of channels etc.. Free falling or sliding parts with defined flight path can be detected and counted by the LS 725. Application on punching machines, feeding units, in the packaging industry for counting and dosage procedures.
Channel
4. Laboratory technology and chemical area Application of the LS 725 e.g. for drop counting. A significant advantage of the LS 725, is here that as described under 2, the object to be detected, small part or drop, may move through the complete range of the optics (15mm) and will still be securely detected.
5. Wire wrapping machines Especially multi wrapping units signal a wire break through mechanical spring arm allocation. Every spring arm has an assigned micro switch. After a wire break, one or more swivel arm can be monitored by an LS 725. swivel arm after wire break swivel arm position loaded
VS 725/4 - 02
0202
– 687 –
Page 688
Page 689
Leuze electronic Information sheet Cable lengthening on mini photoelectric sensors All gallium mini devices of Leuze photoelectric sensor program are mainly used in connection with amplifiers. In these amplifier power supply units, the current pulses for the transmitter supply are generated. Simultaneously, the receiver signals for relay operation respectively the transistor output are amplified. The electrical signal between the receiver and the transmitter is not yet amplified, i.e. of high-impedance and therefore exposed for possible capacitive or inductive interferences. For that reason the receiver cables of the mini sensor are shielded. This shield is important for interference free function! The original device cable may not be lengthened or replaced by common installation cables NYA or NYAF. Combination of several photoelectric sensor systems in one cable, even if shielded, can cause interferences. In addition to that, the shielded photoelectric sensor cables should not be lead together with other lines in one common plug connection.
Our recommendations are: 1. Allocation in a way that the length of the sensor standard cables suffices to reach the amplifier. Amplifier close to the scanning place. From the amplifier output, the contact signal can be transmitted via cables of any length. 2. If an allocation as described under 1. is impossible, we recommend a cable lengthening by using an original cable (order code: e.g. "4m cable for RK 72"). The transition has to be performed in a way that the shield is continued without interruption. We recommend not to exceed 10m as maximum distance between gallium mini device and amplifier.
A B C D E F
Mini sensor Amplifier VS … Relay contact To the machine control system Any cable length Original cable without join
Information sheet mini sensor technology
0202
– 689 –
Page 690
Leuze electronic KK 05
Capacitive sensor Dimensioned drawing
0.2 …2.0mm 24 V DC l Capacitive sensor for mass detection l Connection via M8 connector for fast installation l NPN/ PNP output l Switching state display
We reserve the right to make changes • MS_c05e.fm
A B
ISO 9001
IEC 60947...
IP 40
IEC 60947...
C D E
Use only plastic screws with this mounting option! Plastic part: the mounting parts have to keep a distance of min. 3mm from the plastic part in all directions! Measurement part Approaching plane Indicator diode
Electrical connection
Accessories: (available separately)
l Ready-made cables (KB …)
Leuze electronic GmbH + Co. http://www.leuze.de
Post-box 1111 D-73277 Owen-Teck Tel. ++49 7021 5730
– 690 –
KK 05 - 02
Page 691
Page 692
Leuze electronic
Leuze electronic GmbH + Co. http://www.leuze.de
Post-box 1111 D-73277 Owen-Teck Tel. ++49 7021 5730