Page 603

Leuze electronic 518 Series Dimensioned drawings

M12 connectors

Selection table

For devices with M12 connectors, there are available: connectors with ready made cables and 2 conductor sockets with screw connection.

M12 connectors

Protection class (DIN 40050) plugged and screwed: IP 67 with 4-wire cable 2m cable length KB 450-2000-4 without cable KD 095-5

KD 095-5A

Important: With throughbeam photoelectric sensors, a connector is required both for the transmitter and the receiver.

KB 450-2000-4A

5m cable length KB 450-5000-4

KB 450-5000-4A

10m cable length KB 450-10000-4

KB 450-10000-4A

Dimensioned drawings

Mounting systems BT 518.1

518 Series Accessories - 03

0202

– 603 –

Page 604

Leuze electronic

Leuze electronic GmbH + Co. http://www.leuze.de

Post-box 1111 D-73277 Owen-Teck Tel. ++49 7021 5730

– 604 –

Page 605

Leuze electronic

618 Series Overview and advantages Cylindrical and short M18 metal housing

Operating principles: - Throughbeam photoelectric sensors - Retro-reflective photoelectric sensors with polarisation filter - Energetic diffuse reflection light scanners

The switching frequency of 500Hz enables the detection of fast events

10 … 30VDC supply voltage and PNP transistor output with light or dark switching

M12 connector for fast installation

– 605 –

Page 606

Leuze electronic Sensor selection table

0 … 12m

•

PRK 618/4-S12

0 … 7.0m

•

RT 618/4-200-S12

0 … 0.3m

•

•

•

•

•

•

AS-interface

•

AS-i system

•

NPN transistor

PNP transistor

Output

•

•

– 606 –

Operating voltage

10 … 30VDC

LS 618/4-S12

Light source

Infrared

Housing

Red light

Typ. oper. range limit/ typ. scan. range limit

Stainless steel

Designation

Metal

Operating principle

Page 607

M12 connector

500Hz

• •

500Hz

• •

500Hz

• • •

– 607 –

Focussed light beam

Transparent media

Sensitivity adjustment

Activation input

Connection

Background suppression

Switching

Polarisation filter

Switching frequency

Warning output

Light/dark

Leuze electronic

Options Page

• 609

• 611

• 613

Page 608

Specifications and description

Leuze electronic

LS 618

Throughbeam photoelectric sensors Dimensioned drawing

12m 10 - 30 V DC l Throughbeam photoelectric sensor with light/dark switching l Robust cylindrical metal housing M18x1 l Sensitivity adjustment for optimal adaptation to the application l Dual LED display for easy commissioning l M12 connector for fast installation

We reserve the right to make changes • 618_a01e.fm

A B C

ISO 9001

Sensitivity adjustment Indicator diode Optical axis

Electrical connection IP 67

500 Hz IEC 60947...

IEC 60947...

Accessories: (available separately • see page 614)

l M12 connectors (KD …) l Ready-made cables (KB …) l 90° deflection head

Leuze electronic GmbH + Co. http://www.leuze.de

Post-box 1111 D-73277 Owen-Teck Tel. ++49 7021 5730

– 608 –

LSS 618-S12 - 01 LSE 618/4-S12 - 01

Page 609

The text of this page cannot be shown here; see it in the PDF.

Page 610

Leuze electronic PRK 618

Retro-reflective photoelectric sensors Dimensioned drawing

0 … 7.0m 10 - 30 V DC l Retro-reflective photoelectric sensor with light/dark switching l With visible red light and polarisation filter l Robust cylindrical metal housing M18x1 l Sensitivity adjustment for optimal adaptation to the application l Dual LED display for easy commissioning l M12 connector for fast installation

We reserve the right to make changes • 618_b01e.fm

A B C

ISO 9001

Sensitivity adjustment Indicator diode Optical axis

Electrical connection IP 67

500 Hz IEC 60947...

IEC 60947...

Accessories: (available separately • see page 614)

l M12 connectors (KD …) l Ready-made cables (KB …) l Reflectors l Reflective tapes l 90° deflection head

Leuze electronic GmbH + Co. http://www.leuze.de

Post-box 1111 D-73277 Owen-Teck Tel. ++49 7021 5730

– 610 –

PRK 618/4-S12 - 01

Page 611

The text of this page cannot be shown here; see it in the PDF.

Page 612

Leuze electronic RT 618

Energetic diffuse reflection light scanner Dimensioned drawing

0 … 300mm 10 - 30 V DC l Energetic diffuse reflection light scanner with light/dark switching l Robust cylindrical metal housing M18x1 l Sensitivity adjustment for optimal adaptation to the application l Dual LED display for easy commissioning l M12 connector for fast installation

We reserve the right to make changes • 618_c01e.fm

A B C

ISO 9001

Sensitivity adjustment Indicator diode Optical axis

Electrical connection IP 67

500 Hz IEC 60947...

IEC 60947...

Accessories: (available separately • see page 614)

l M12 connectors (KD …) l Ready-made cables (KB …) l 90° deflection head

Leuze electronic GmbH + Co. http://www.leuze.de

Post-box 1111 D-73277 Owen-Teck Tel. ++49 7021 5730

– 612 –

RT 618/4-200-S12 - 01