The text of a manual · part 56 of 105
Catalog: Optical electronic sensors: Cylindrical Series – Mini photoelectric sensors – Fibre optic devices, pages 533 to 542
Pages 533 to 542 of 1000, from Catalog: Optical electronic sensors
The original document is the PDF (46 MB). This is its text as extracted, unedited; tables and drawings read best in the PDF, and each page heading opens it at that page.
For the Leuze FRK 92, Leuze PRK406 and Leuze PRK 3
Page 533
Leuze electronic
Optical Sensor ABCs
Cubic Series
Cylindrical Series – Mini photoelectric sensors – Fibre optic devices
Forked Photoelectric Sensors
Measuring Sensors
Contrast Scanners – Colour Sensors – Luminescence Scanners
Explosion Protection
Protective Photoelectric Sensors – Type 2
Accessories
Further Product Range
Appendix – Index
– 533 –
Page 534
Leuze electronic
– 534 –
Page 535
Leuze electronic
Cylindrical Sensors - Selection Tables Overview Table 1 Throughbeam photoelectric sensors Transmitter and receiver are contained in different housings. The sensor beam travels the whole way only once. Large operating ranges are possible. Those devices are especially suited if heavy contamination occurs.
Table 2
The Selection Table Even though the product variety is huge, it is easy to find the right optical sensor for the corresponding application. By using the clear selection tables, the correct device can be found in no time. Basic questions are answered quickly with the optical ABC. In cases where technical problems can not be solved, the people at Leuze are available to serve you with their special knowledge.
Hotline No. +49 70 21 / 573-217
Retro-reflective photoelectric sensors Transmitter and receiver are located in one housing. The beam of the transmitter meets the reflector and is retrodirected to the receiver of the photoelectric sensor. The electrical wiring is therefore only required on one side.
Table 3 Diffuse reflection light scanners Transmitter and receiver are located in one housing. The transmitters’ beam however, is returned by the surface to be scanned itself. The scanning range depends on the sensor performance and the reflective properties of the material surface.
– 535 –
The Selection
Page 536
Leuze electronic Table 1 - Throughbeam photoelectric sensors Figure
Series
Typ. operating range limit in m
8m
10m
12m
318 Series
412 Series
518 Series
13
8
10
11
12
618 Series
– 536 –
20m
45m
20
45
Page 537
•
•
– 537 –
• • • 1000Hz
• • • •
• • 500Hz
• • • • •
• • • • 1000Hz
• • • •
• • • 500Hz
• • • •
• •
•
Dynamic
Options
Protective photoelectric sensor AOPD type 2
Low temperature/optics heating
Time delay
Sensitivity adjustment
Housing
Activation input
Warning output
Plastic
Stainless steel
Connection
Metal
Cable
Terminals
Plug
Switching
M18 connector
M12 connector
M8 connector
Dark
Switching frequency
Light
Switching output
Hz (transistor/relay)
AS-interface
Relay
Operating voltage
NPN transistor
PNP transistor
AS-interface
AC/DC
Light source
DC
Laser
Infrared
Red light
Leuze electronic Application Page
• • 543
• 571
• • 583
• 605
Page 538
Leuze electronic Table 2 - Retro-reflective photoelectric sensors Figure
Series
Typ. operating range limit in m
1m
3m
318 Series
412 Series
518 Series
4m
5m
3.4
1.6
4.8
7m
6
3
3
3.5
4.5
7
618 Series
– 538 –
Page 539
– 539 –
• • • • • 1000Hz
• • • •
• • • 700Hz
• • • • •
• • • • • 1000Hz
• • • •
• • • 500Hz
• • • •
• •
•
Transparent media
Options
Polarisation filter
Low temperature/optics heating
Time delay
Sensitivity adjustment
Housing
Activation input
Warning output
Plastic
Stainless steel
Connection
Metal
Cable
Terminals
Plug
Switching
M18 connector
M12 connector
M8 connector
Dark
Switching frequency
Light
Switching output
Hz (transistor/relay)
AS-interface
Relay
Operating voltage
NPN transistor
PNP transistor
AS-interface
AC/DC
Light source
DC
Laser
Infrared
Red light
Leuze electronic Application Page
• • • 543
• • 571
• • • 583
• • 605
Page 540
Leuze electronic Table 3 - Diffuse reflection light scanners Figure
Series
Typ. scanning range limit in mm
100mm
318 Series
110
200mm
300mm
250
500
800mm
700
400
412 Series
518 Series
500mm
130
250
500
300
618 Series
– 540 –
800
Page 541
•
•
– 541 –
• • • 1000Hz
• • • •
• • 500Hz
• • • • •
• • • • 1000Hz
• • • •
• • • 500Hz
• • • •
• •
•
• •
Focussing
Options
Background suppression
Low temperature/optics heating
Time delay
Housing
Sensitivity adjustment/Scanning range
Activation input
Warning output
Plastic
Stainless steel
Connection
Metal
Cable
Terminals
Plug
Switching
M18 connector
M12 connector
M8 connector
Dark
Switching frequency
Light
Switching output
Hz (transistor/relay)
AS-interface
Relay
Operating voltage
NPN transistor
PNP transistor
AS-interface
AC/DC
Light source
DC
Laser
Infrared
Red light
Leuze electronic Application Page
543
• 571
• 583
• 605
Page 542
Leuze electronic
– 542 –