Browse
(440) 299-7778
Menu
(440) 299-7778
One-year parts and labor warranty30-day money-back guaranteeEnglishEspañolContact

The text of a manual · part 53 of 105

Catalog: Optical electronic sensors: Cubic Series, pages 509 to 518

Pages 509 to 518 of 1000, from Catalog: Optical electronic sensors

The original document is the PDF (46 MB). This is its text as extracted, unedited; tables and drawings read best in the PDF, and each page heading opens it at that page.

For the Leuze FRK 92, Leuze PRK406 and Leuze PRK 3

Page 509

The text of this page cannot be shown here; see it in the PDF.

Page 510

Accessories

Leuze electronic

85 Series

Accessories

Additional information in section "Accessories" from page 925 onwards!

Reflectors

Dimensioned drawings l Reflectors and reflective tapes are ideally suited for Leuze retro-reflective photoelectric sensors. The performance data refer to the use of Leuze reflectors and reflective tapes. The range of retro-reflective photoelectric sensors depends on the type and size of the reflector. l Adhesive and screw type versions permit universal installation. l Precise optical alignment is not required, as the reflector may be slightly inclined relative to the optical axis. l For retro-reflective photoelectric sensors with polarisation filters, only triad-type reflectors made of plastic or reflective tape No. 2 may be used.

Selection table

Order codes:

We reserve the right to make changes • 85_zu_e.fm

Tape No. 2

Designation

Part No.

TKS 100x100 TK 100x100 TKS 50x100 TK 50x100 TKS 50x50 TKS 30x50 TK 30x50 TK 82 TK 60 TK 45 TK 35 Tape 2 TG 60 TG 29 TG 6 KB 095-5000-5 KB 095-5000-5A KD 095-5 KD 095-5A BT 85 ARH 2

500 22816 500 03192 500 22815 500 03191 500 22814 500 23525 500 03189 500 03187 500 03186 500 03185 500 03184 500 11523 500 03179 500 09374 500 03176 500 20500 500 20499 500 20502 500 20501 500 03376 500 23547

Leuze electronic GmbH + Co. http://www.leuze.de

Designation

Temp. range

Dimensions [mm]

TKS 100x100 TK 100x100 TKS 50x100 TK 50x100 TKS 50x50 TKS 30x50 TK 30x50 TK 82 TK 60 TK 45 TK 35 Tape 2 TG 60 TG 29 TG 6

-20°C/+60°C -20°C/+60°C -20°C/+60°C -20°C/+60°C -20°C/+60°C -20°C/+60°C -20°C/+60°C -20°C/+60°C -20°C/+60°C -20°C/+60°C -20°C/+60°C -20°C/+60°C -20°C/+120°C -20°C/+120°C -20°C/+120°C

124.6 100 9.5 99 99 9 124.6 53.5 9.5 99 49.5 9 75 53.6 9.5 75 34.5 9.5 48 32 6.8 84 9 64 8 46 8 35.5 5 100 100 60 9 24 29 6.5 14.5 6 5 a 2) 2)

2) 1)

b c

Fastening screw type l m l m l l m l l l adhesive l l l l l l l l

1) heating capability (HTK 82) 2) for screw mounting use mounting bracket

Post-box 1111 D-73277 Owen-Teck Tel. ++49 7021 5730

– 510 –

85 Series Accessories - 02

Page 511

Leuze electronic 85 Series Dimensioned drawings

Connectors, plugs, cables

Leuze electronic offers connectors with readymade cables in various lengths suited for the connector-type devices. Select the appropriate cable for the device with the desired cable length from the following tables.

Selection table

For devices with M12 connectors, there are available: 4 connectors with ready-made 5m cable and 2 connectors with screw connection.

M12 connectors

When ordering throughbeam photoelectric sensors, keep in mind that a connector is required both for the transmitter and receiver. with cable (5m cable length) KB 095-5000-5

KB 095-5000-5A without cable KD 095-5

KD 095-5A

Dimensioned drawings

Mounting systems

BT 85

BT 85

85 Series Accessories - 02

0202

– 511 –

Page 512

Leuze electronic

Leuze electronic GmbH + Co. http://www.leuze.de

Post-box 1111 D-73277 Owen-Teck Tel. ++49 7021 5730

– 512 –

Page 513

Leuze electronic

78 Series Overview and advantages Extensive sensor series: - In robust metal housing with glass optics - In protection class IP 65

Operating principles: - Throughbeam photoelectric sensors - Protective throughbeam photoelectric sensors - Retro-reflective photoelectric sensors - Energetic diffuse reflection light scanners - Diffuse reflection light scanners with background suppression

- Infrared light for increased indifference to ambient light - Large operating range

- Numerous AC/DC supply voltage possibilities: 12 … 30VDC, 10 … 30VDC, 115/230VAC, 24/42VAC, 24/48VAC - Different outputs: NPN, PNP, relay

Comfortable terminal compartment for individual electrical connection

Universal mounting system for better alignment

Options: - Activation input - Switching delay - De-humidifying system - Optics heating

– 513 –

Page 514

Leuze electronic Sensor selection table

180m

LS 78/7

180m

LS 78/7.2

450m

LS 78/7 Z4

180m

LS 78/74 R.8

180m

LS 78/7 24/42 V

180m

LS 78/7 24/48 V

180m

SLS 78M/P-1730-T2-4

150m

SLS 78M/P-1750-T2-2

150m

SLS 78M/PR-1761-T2-2

150m

RK 78/2

7.5m

RK 78/4 R

7.5m

RK 78/7

7.5m

RK 78/7-24-48 V

7.5m

RK 78/7 Z1-42 VS

7.5m

RK 78/7 Z4

7.5m

RK 78/7 Z4-24-48 V

7.5m

RK 78/4 R-300

300mm

RK 78/4 R-800

800mm

RK 78/4 R-2000

2m

RK 78/7-300

300mm

RK 78/7-800

800mm

RK 78/7-2000

2m

RK 78/7-300-24-48 V

300mm

RK 78/7-800-24-48 V

800mm

RK 78/7-2000-24-48 V

2m

FRK 78/4 R-800

800mm

FRK 78/7-800

800mm

FRK 78/7-800-24-48 V

800mm

• • • • • • •

• • • • • • •

• •

• • • • • • • • •

• • • • • • • • •

• • •

• • •

• • •

•

– 514 –

• • • •

•

42VAC

•

24/48VAC

• • • • • • • • • • •

24/42VAC

• • • • • • • • • • •

10 … 30VDC

Operating voltage

24VDC

180m

LS 78/4.8.1

Light source

115/230 VAC

LS 78/24 R

Housing

11 … 30VDC

Typ. operating range limit/scanning range

Infrared

Designation

Metal

Operating principle

•

• • • • •

• •

• •

• •

•

• • • • • •

• • •

• •

•

Page 515

Leuze electronic

• • • • • • • •

• • • • • • • •

20Hz 20Hz 20Hz 100Hz

20Hz 20Hz 20Hz

300Hz 200Hz

•

•

200Hz

20Hz

100Hz

•

• • •

•

• • • • • •

100Hz

• • • • • • • • •

100Hz

20Hz

100Hz

20Hz

100Hz

20Hz

• • •

100Hz

20Hz 20Hz 20Hz 20Hz 20Hz 20Hz

20Hz 20Hz 20Hz 20Hz 20Hz 20Hz

20Hz 20Hz 20Hz

•

• • • • •

•

• • •

Page

Time module ZK 7820 already integrated

• • • • • • • • • • •

Remark

Time modules ZK 7810 and ZK 7820 pluggable

20Hz

100Hz

Activation input

Terminals

100Hz

Options

M12 connector

Dark

• • •

Light

•

• (•) • • • • • •

Connection

Relay

• •

Switching

NPN/PNP transistor

PNP transistor

•

Switching frequency

Relay

NPN transistor

Output

• • •

• • •

517 517 519 519 519 519 519 519 521 523 523

• • • • • • •

• • • • • • •

• • • • • • •

• • • •

• • • • • • • • •

• • • • • • • • •

• • • • • • • • •

• • • • • • • • •

527 527 527 527 527 527 527 527 527

• • •

• • •

• • •

• • •

529 529 529

– 515 –

• • •

525 525 525 525 525 525 525

Page 516

Specifications and description

Leuze electronic

LS 78

Throughbeam photoelectric sensors Dimensioned drawing

180m 10 - 30 V DC l Voltage ranges from 12 … 30V and 10 … 30V with NPN, PNP and/or relay outputs l Light/dark switching in each device l Universal connection via terminals l Additional plug-in time module l Special type with activation input l Integrated optics heating

We reserve the right to make changes • 78_a01e.fm

ISO 9001

IEC 60947...

A B C D E

Removable lid • cheese head screw DIN 6912 M5x16 (machined) Optical axis Indicator diodes Device fixture M6x9 Device fixture M6x12

Electrical connection Transmitter

IP 65

Receiver

IEC 60947...

Accessories: (available separately • see page 530)

l Mounting systems (BT 16, UMS 78) l Fastening adapter BT 08 l Diaphragm BL 04 l Time module transient pulses ZK 7810 l Time module slow operation/release ZK 7820 l Alignment aid ARH 2

Leuze electronic GmbH + Co. http://www.leuze.de

1. Operation with activation: no connection between 1 and 2 2. Operation without activation: make a connection between 1 and 2

Post-box 1111 D-73277 Owen-Teck Tel. ++49 7021 5730

– 516 –

LS 78/24 R - 02 LS 78/4.8.1 - 02

Page 517

The text of this page cannot be shown here; see it in the PDF.

Page 518

Leuze electronic LS 78

Throughbeam photoelectric sensors Dimensioned drawing

180m 450m 115/230 V

24/48 V

24 V

AC

AC

DC

24 / 42 V AC l AC voltage 115/230V, 24/42V, 24/48V and DC voltage 24V l Light/dark switching in each device l Universal connection via terminals l Devices with integrated or separate add-on time module l Special type with activation input

We reserve the right to make changes • 78_a02e.fm

ISO 9001

IEC 60947...

A B C D E

Removable lid • cheese head screw DIN 6912 M5x16 (machined) Optical axis Indicator diodes Device fixture M6x9 Device fixture M6x12

Electrical connection Transmitter

Receiver

IP 65

IEC 60947...

Accessories: (available separately • see page 530)

l Mounting systems (BT 16, UMS 78) l Alignment aid ARH 2 l Test monitoring unit: - TNT 32 (Part No. 500 20476) - TNT 33 (Part No. 500 28158) - TNT 34 (Part No. 500 81023) 1. Operation with activation: no connection between 1 and 2 2. Operation without activation: make a connection between 1 and 2

Leuze electronic GmbH + Co. http://www.leuze.de

Post-box 1111 D-73277 Owen-Teck Tel. ++49 7021 5730

– 518 –

LS 78/7 … - 02