The text of a manual · part 48 of 105
Catalog: Optical electronic sensors: Cubic Series, pages 459 to 468
Pages 459 to 468 of 1000, from Catalog: Optical electronic sensors
The original document is the PDF (46 MB). This is its text as extracted, unedited; tables and drawings read best in the PDF, and each page heading opens it at that page.
For the Leuze FRK 92, Leuze PRK406 and Leuze PRK 3
Page 459
Page 460
Leuze electronic PRK 96
Retro-reflective photoelectric sensors with polarisation filter Dimensioned drawing
10m 10 - 30 V DC l Polarised retro-reflective photoelectric sensor with large operating range in visible red light l Robust plastic housing, protection class IP 67 for industrial application l Complementary PNP switching outputs for PLC applications (light/dark switching) l Status display with integrated blink mode for soiling and misalignment
We reserve the right to make changes • 96_b11e.fm
ISO 9001
IEC 60947...
A B C D E F G H I K
Indicator diode green Indicator diode yellow Receiver Transmitter Optical axis Device plug M12x1 Screwed cable gland M16x1.5 for Ø 5 … 10mm Countersinking for SK nut M5, 4.2 deep Connection terminals Cable entry
Electrical connection IP 67
IEC 60947...
Accessories: (available separately • see page 484)
l Mounting systems (BT 96, BT 96.1, UMS 96, BT 450.1-96) l Spark extinction l Reflectors l Reflective tapes
Leuze electronic GmbH + Co. http://www.leuze.de
Post-box 1111 D-73277 Owen-Teck Tel. ++49 7021 5730
– 460 –
PRK 96 K/P-2360-28 (K types) - 02
Page 461
Page 462
Leuze electronic PRK 96
Retro-reflective photoelectric sensors with polarisation filter Dimensioned drawing
0 … 8.5m 10 - 30 V DC l Retro-reflective photoelectric sensor for detection of transparent media l Robust metal housing with glass cover, protection class IP 67 for industrial application l User controlled sensitivity adjustment l The autocollimation principle used ensures that the device functions reliably over the entire range (0 … max.) l High switching frequency for detection of fast events l Connection via M12 connector or terminal compartment
We reserve the right to make changes • 96_b12e.fm
ISO 9001
IEC 60947...
A B C D E F G H I
Indicator diode green Indicator diode yellow Optical axis Device plug M12x1 Screwed cable gland M16x1.5 for Ø 5 … 10mm Countersinking for SK nut M5, 4.2 deep Connection terminals Cable entry Sensitivity adjustment
Electrical connection IP 67
IEC 60947...
Accessories: (available separately • see page 484)
l Mounting systems (BT 96, UMS 96, BT 450.1-96) l M12 connectors (KD …) l Reflectors l Reflective tapes l Alignment aid ARH 96
Leuze electronic GmbH + Co. http://www.leuze.de
Post-box 1111 D-73277 Owen-Teck Tel. ++49 7021 5730
– 462 –
PRK 96 M/P-2838-28 (K types) - 02 PRK 96 M/P-2838-48 (K types) - 02
Page 463
Page 464
Leuze electronic RT 96
Energetic diffuse reflection light scanners Dimensioned drawing
50 … 700mm 50 … 1200mm 10 - 30 V DC l Robust metal housing with glass cover or plastic housing, protection class IP 67 for industrial application l General light/dark switching, sensitivity adjustment and delay before start-up provide for optimal adaptation to the application l Minimal short range l Connection via M12 connector or terminal compartment l Multiple options with warning output, activation input, switching delays and optics heating for use at low temperatures
We reserve the right to make changes • 96_c01e.fm
ISO 9001
IEC 60947...
A B C D E F G H I K L M N
Indicator diode green Indicator diode yellow Receiver Transmitter Optical axis Device plug M12 Screwed cable gland M16x1.5 for Ø 5 … 10mm Countersinking for SK nut M5, 4.2 deep Output with option switching delay Connection terminals Cable entry Sensitivity adjustment Light/dark switching
Electrical connection IP 67
IEC 60947...
Accessories: (available separately • see page 484)
l Mounting systems (BT 96, BT 96.1, UMS 96, BT 450.1-96) l M12 connectors (KD …)
Leuze electronic GmbH + Co. http://www.leuze.de
Post-box 1111 D-73277 Owen-Teck Tel. ++49 7021 5730
– 464 –
RT 96 M/P… - 05
Page 465
Page 466
Leuze electronic RT 96
Energetic diffuse reflection light scanners Dimensioned drawing
50 … 1200mm 20 … 1200mm 10 - 30 V DC l Robust metal housing with glass cover or plastic housing, protection class IP 67 for industrial application l General light/dark switching, sensitivity adjustment and delay before start-up provide for optimal adaptation to the application l Minimal short range l Connection via M12 connector or terminal compartment l Multiple options with warning output, activation input, switching delays and optics heating for use at low temperatures
We reserve the right to make changes • 96_c04e.fm
ISO 9001
IEC 60947...
A B C D E F G H I K L M N
Indicator diode green Indicator diode yellow Receiver Transmitter Optical axis Device plug M12 Screwed cable gland M16x1.5 for Ø 5 … 10mm Countersinking for SK nut M5, 4.2 deep Output with option switching delay Connection terminals Cable entry Sensitivity adjustment Light/dark switching
Electrical connection IP 67
IEC 60947...
Accessories: (available separately • see page 484)
l Mounting systems (BT 96, BT 96.1, UMS 96, BT 450.1-96) l M12 connectors (KD …)
Leuze electronic GmbH + Co. http://www.leuze.de
Post-box 1111 D-73277 Owen-Teck Tel. ++49 7021 5730
– 466 –
RT 96 K/P… - 05
Page 467
Page 468
Leuze electronic RT 96
Energetic diffuse reflection light scanners Dimensioned drawing
50 … 700mm 50 … 1200mm 20-230 V AC / DC l Energetic scanner with sensitivity adjustment in visible red light or infrared light l Robust metal housing with glass cover or plastic housing, protection class IP 67 for industrial application l General light/dark switching, sensitivity adjustment and delay before start-up provide for optimal adaptation to the application l Version with additional switching delay l Connection via comfortable terminal compartment up to 1.5mm²
We reserve the right to make changes • 96_c02e.fm
ISO 9001
IEC 60947...
A B C D E F G H I K L M
Indicator diode green Indicator diode yellow Receiver Transmitter Optical axis Screwed cable gland M16x1.5 for Ø 5 … 10mm Countersinking for SK nut M5, 4.2 deep Output with option switching delay Connection terminals Cable entry Sensitivity adjustment Light/dark switching
Electrical connection IP 67
IEC 60947...
Accessories: (available separately • see page 484)
l Mounting systems (BT 96, BT 96.1, UMS 96, BT 450.1-96) l Spark extinction
Leuze electronic GmbH + Co. http://www.leuze.de
Post-box 1111 D-73277 Owen-Teck Tel. ++49 7021 5730
– 468 –
RT 96 K/R… - 05 RT 96 M/R… - 05