The text of a manual · part 4 of 105
Catalog: Optical electronic sensors: Optical Sensor ABCs, pages 21 to 28
Pages 21 to 28 of 1000, from Catalog: Optical electronic sensors
The original document is the PDF (46 MB). This is its text as extracted, unedited; tables and drawings read best in the PDF, and each page heading opens it at that page.
For the Leuze FRK 92, Leuze PRK406 and Leuze PRK 3
Page 21
Leuze electronic AS interface
Housing
Diaphragms
Photoelectric sensors are located in either a robust plastic or metal housing.
In order to detect small objects over great distances, appropriate pin or slit diaphragms, which are fitted on the transmitter and receiver, are offered for some throughbeam photoelectric sensors.
Especially under rough operating conditions, the use of metal-type devices which offer special protection against mechanical and chemical influences is recommended.
The AS-interface is an optimised bus system for the lowest field level of the automation technology
Optics
Aim of the AS-interface is the cost saving connection of binary sensors and actuators to a primary controller. Voltage supply and data exchange pass through the same (unshielded) two-wire connection. Bus-compatible sensors with integrated AS-i chip can be connected directly to the bus; connection of common sensors is possible through so-called coupling modules.
The light outlet surface of a photoelectric sensor is, depending on the model, made of plastic or glass. Covers or optics made of hard glass fulfil the highest requirements. They are resistant against detergents, chemicals and scratching. To increase the effectiveness of the optics and to reduce the effects of possible contamination, glass as well as plastic optics have the largest possible surface area.
The tree structure of the AS-i bus system as well as the technical key features enable a considerable reduction of expenditures during wiring and installation. The AS-interface is therefore a future-oriented alternative to standard parallel wiring.
As a result e.g. drilling bits can be safely detected even at a distance of several meters. The size of the diaphragm is dependent on the size of the object and the required range.
Protection classes In order to make the protection of housings against foreign objects and water comparable, the protection classes have been defined in DIN 40050. The first digit refers to the protection against foreign objects, the second to water protection. Almost every sensor is dustproof and protected against immersion.
Equipment Power supply unit
AS-i Master PLC
First digit
Contact protection and Second Water protection foreign object protection digit
0
No special protection
0
No special protection
1
Against large foreign objects, dia. > 50mm
1
Against vertically falling water drops
2
Against medium foreign objects, dia. > 12mm
2
Against angled falling water drops (up to 15° from vertical)
3
Against small foreign objects, dia. > 2.5mm
3
Against sprayed water (up to 60° from vertical)
4
Against corn-formed foreign objects, dia. > 1mm
4
Against splashed water from all directions
5
5 Dust protected; dust deposits permitted but not in quantities which interfere with the function of the device
Against water jets from a nozzle from all directions
6
Dust proof
6
Against flooding
7
Against dipping
8
Against submerging
Sensors with AS-i chip
Sensors without AS-i chip
Sensors without AS-i chip
Coupling module
Bus coupling
Protection classes acc. to IEC 529 and/or DIN 40050
– 21 –
Page 22
Leuze electronic Connection types
Outputs
Push-pull transistor output
There are three common types of connection for optical electronic sensors: plugs, cables or terminals.
Optical electronic sensors are most commonly offered with relay or transistor output. Relay outputs with changeover contacts are the most universal, however, they also have their disadvantages: relays require a large amount of space, their time delays cannot be accepted in every application, and, due to their moving parts, their operating life is limited.
This type of transistor output has a low impedance and is immune to interference (push-pull technology). The outputs can be used in connection with both, PNP and NPN control systems. The output automatically recognises the connected hardware. Symmetric response behaviour is a further advantage. Push-pull outputs must not be connected in parallel.
The three different possibilities can be easily identified in the connection illustrations of the individual devices.
Devices with this connection diagram are connectable via plugs. Ready-made cables with fitting connectors are available for almost every sensor.
The user can choose between NPN, PNP and push-pull type transistor outputs. It is therefore optimally compatible with the respective control system to be connected.
PNP transistor outputs The PNP transistor output is a highimpedance switching output with open collector. It switches positive potential to the connected load. These devices have a cable connection, usually with a 2m cable. Special cable lengths are available upon request.
Short-circuit protection Transistor outputs are usually shortcircuit proof. This is achieved by monitoring the output current and, should it exceed a certain level, cutting off the supply to the transistor. The information on the maximum current given on the data sheet have to be observed despite the short-circuit protection.
Devices with this connection diagram are equipped with screw terminals. Cables are fed through PG cable glands. NPN transistor outputs Switching delay Photoelectric sensors or amplifiers with integrated switching delay work with slow operation and/or slow release. Slow operation is used if short events need to be suppressed. Slow release prolongs the duration of the output signals which is often necessary for control purposes.
The NPN transistor output is a highimpedance switching output with open collector. It switches GND to the connected load.
– 22 –
Page 23
Leuze electronic Sensors with laser transmitter
(LASER = Light Amplification by Stimulated Emission of Radiation) Laser diodes as sensor light source enable the realisation of higher operating and scanning ranges with small beam geometries. Red light laser diodes offer the advantage of fast function control and alignment. The beam output is expressed by the laser class. On sensors of the laser class 1 + 2, no additional protective measures are specified.
Laser safety classes
Laser security
Laser-specific regulations are included in the European Standard EN 60825 Safety of Laser Devices. The products are divided into danger classes according to the intensity of the laser light and the safety measures contained either within the device or to be provided outside of the device.
For the use of laser products of Leuze electronic, the standard IEC 60825-1-am2 applies: Do not stare into the beam - not even with optical instruments.
Class 1: The accessible laser radiation is not dangerous - integrated safety by means of constructive measures such as laser power monitoring Class 2: Due to low transmitting power, the accessible laser radiation is usually not dangerous. Natural reflex reaction (eyelid closure) is usually adequate eye protection. Class 3A: Looking directly into the laser beam with optical aides, such as a telescope or magnifying glass, may be dangerous. Class 3B: Looking directly into the beam in the vicinity of the laser is dangerous Class 4: High laser power - even diffuse reflection may be dangerous, e.g. for skin and eyes.
In connection with visible beams, eyeprotection is usually guaranteed through the eye lid closing reflex. The standard prescribes that the laser beam path should be closed at the end of its purpose-oriented way, where this is practically and responsibly possible. Do not point the laser at people (head level).
Application of laser optical sensors All laser sensors work with small light spots. Through this, a corresponding object resolution and exact positioning is achieved. In order to use these advantages, throughbeam and retro-reflective photoelectric sensors are equipped with a mechanical focus adjustment (collimator). Through this, the light spot can be optimally adjusted to the application over the complete working distance.
Laser optical sensors
– 23 –
Page 24
Leuze electronic Parallel and serial connection
Alignment of optical sensors
A direct logical linking is possible on optical sensors with PNP or NPN transistor outputs. Through internal protective circuits, up to ten sensors with equal output potential (PNP or NPN) can be connected to a parallel circuit. This can be useful for, among other things, collective messages (e.g. from warning outputs).
The optimal alignment is absolutely required for fault-free function characteristics.
An activation input is needed in order to connect several sensors in series. That means that, for example, the PNP output of the first device has to be connected to a "positively" activated input of the second device etc. Both parallel and serial connection can be performed directly on the devices with PNP or NPN transistor outputs. This reduces wiring requirements and PLC capacity in the form of inputs and outputs. Parallel connection of optical sensors with push-pull transistor output is not permitted.
With throughbeam photoelectric sensors, the transmitted beam should meet the receiver’s optics as centrally as possible. For this purpose, the light beam is to be corner-cut from all four directions, e.g. with a piece of cardboard. When optimally aligned, the receiver switches with symmetric shadowing. In connection to large ranges, a laser alignment device simplifies the adjustment. For some devices, special alignment and mounting parts with three-point adjustment are available. There are two possibilities for adjusting a retro-reflective photoelectric sensor: the user can cover all four sides of the reflector with an object until the photoelectric sensor output switches. The forward switching points are symmetric if the alignment is optimal. The second possibility involves covering the outer area of the reflector with non-reflective material, then aligning the photoelectric sensor (the material is removed upon conclusion of the procedure). When mounting the reflector, it is essential to observe that it is fixed at right angles towards the light axis. However, variations of up to 15° are unproblematic.
Sensors with red light LED or red light lasers offer simple function control and in addition to that fast and simple alignment.
Performance reserve Receivers of optical sensors require a minimum amount of light to be able to switch (trigger). All light over and above this minimum amount is designated as "performance reserve". A distinction must be made between the internal performance reserve and the performance reserve selected by the user. The internal performance reserve provides the user with additional security that the information given on the data-sheet is not the limit of what is actually possible. If, in individual cases, heavy contamination can be expected, the user should provide additional performance reserve by selecting the sensor with the next higher operating range.
Application Parallel connection
Input signal Contamination, misalignment, etc. Series connection Performance reserve Trigger
Parallel and serial connection
Performance reserve: the light intensity during normal operation is clearly above the minimum value required by the receiver to trigger.
– 24 –
Page 25
Leuze electronic Optics heating and low-temperature versions
+ 60˚C
A typical application would be the monitoring of thin thread on spinning machines. The torn thread passes through the light path only once.
A²LS: Active suppression of extraneous light for optical sensors
User guidance
A2 LS
- 30˚C Optical sensors are designed for a broad temperature range. Extreme conditions, e.g. intense cooling plants, permanent outdoor installation or on gates and sluices with frequent high/low temperature transitions, require special low-temperature versions with optics heating. With permanent optics heating in the front cover, the sensors of, for example, the series 96 can maintain a "clear view" and ensure proper operation all the way down to a frosty -35°C.
Light and dark switching
A²LS is the acronym for Active Ambient Light Suppression, the active suppression of extraneous light. And it functions as follows: For detection of highly-transparent objects, special retro-reflective photoelectric sensors have to be used. Adjustment of these photoelectric sensors is normally very timeconsuming and varies from sensor to sensor. With user guidance, adjustment happens without an object. Through this, a fast and always reproducible adjustment is achieved. For PET, clear and coloured glass, separate operating points are set within the sensor.
Tracking: Automatic contamination compensation With light switching optical sensors, the transistor is switched through if the light path is free and disabled if the light path is interrupted. With dark switching sensors it is the other way around. Many photoelectric sensor types offer the choice between light and dark switching variants. Optical sensors with changeover relay are usable in both operating modes. The user chooses through the respective connection.
Static - Dynamic The optical sensor output directly follows the light reception during static operation. During dynamic operation however, the optical sensor reacts to the change of brightness. A signal of a certain length is deducted from the change of light to dark. Dynamic optical sensors are suitable for applications which would otherwise deliver impulses too short for evaluation.
Tracking PET Glas Sensors for the detection of transparent objects such as foils and glass surfaces are very sensitive to soiling due to their detection characteristics. The tracking function compensates for this gradual soiling. The sensor determines the current reception level and compares this with the initial reference value. In this way, the regulator compensates not only for the soiling, but also for the elevated signal level which occurs after cleaning without the need for new system calibration. It is no longer necessary to stop the machine. In addition, this tracking function makes possible automatic sensor commissioning. Commissioning calibration in the form of a teach-in is no longer necessary. The maintenance intervals are extended considerably.
– 25 –
An optical sensor transmits and receives light at a specific signal frequency and phase. If the sensor detects ambient light which is similar in frequency and/or phase of its own sensor signal, the optical sensor actively and automatically changes its signal or the phase. A high degree of permanent detection reliability is achieved in this way. As a result, not even the pulsed light from energy-saving lamps or other optical sensors has a negative effect on the A²LS optical sensors.
Delay before start-up
UB Q During connection respectively disconnection of the operating voltage to a sensor, different internal standardising procedures are performed. The device is not working during this period. Also during this phase, a short, undefinable output pulse can be generated. The delay before start-up suppresses sensor operation until all device-internal preparations have been concluded. This process takes approximately 50 to 200ms.
Special functions
Page 26
Leuze electronic Typical response behaviour
Typical black/white behaviour Energetic diffuse reflection light scanners and diffuse reflection light scanners with background suppression:
The diagram illustrates the possible offset of the optical axis from the transmitter and receiver as a function of their distance. Detection by the transmitter and receiver takes place within the two curves.
The diagram illustrates the possible offset of the optical axis of the sensor and the boundary of the measured object (90% white) as a function of distance. With larger distances, the edge of the measured object must cover the optical axis in order to be detected.
200 150 100 50 0 -50 -100 -150 -200
Typ. response behaviour (white 90%) 40 y2
30 y1
0
1
2
3
4
5
6
7
8
9
Distance x [m]
Offset y [mm]
Offset y [mm]
Typ. response behaviour y1
20
Diffuse reflection light scanner with background suppression: The diagram illustrates the reduction of the scanning range of differentcoloured measured objects relative to a white measured object as a function of distance. In the diagram, the scanning range reduction from black (6% diffuse reflection) and grey (18% diffuse reflection) relative to white (90% diffuse reflection) is plotted. In this example, a scanning range reduction of 8mm relative to black is read for a scanning range setting on the sensor of 160mm. Thus, the sensor has a scanning range of 152mm on black.
10
Typ. black/white behaviour
0 -10 -20 y2
-30 -40
0
50
100
150
200
250
Distance x [mm] y2 y1 x y2 y1
300 350
Red. of scan range y [mm]
Throughbeam photoelectric sensors:
12 A B C
10 8 6 4 2 0 -2
0
20
40
60
80 100 120 140 160 180
Scanning range x [mm] x
A white 90% B grey 18% C black 6%
Retro-reflective photoelectric sensors: The diagram illustrates the possible offset of the optical axis of the sensor and the boundary of the reference reflector TK 100x100 as a function of the distance.
y x
The sensor is detected by the reflector within the two curves.
Typ. response behaviour (TK 100x100)
Offset y [mm]
150 100 y2
50 0
Diagram types
-50 y1
-100 -150
0 0,5 1 1,5 2 2,5 3 3,5 4 4,5 5
Distance x [m] y2 y1 x
– 26 –
Page 27
Leuze electronic Optical sensors for the potentially explosive area
In order to use optical sensors in potentially explosive atmospheres, it is necessary to take constructive measures to avoid the explosion of an inflammable mixture even if an error occurs. The principle of such a measure is marked by the protection method (examples: pressurisation or intrinsic safety). The protection method intrinsic safety is available for all sensor operating principles. They are examined and equipped with the respective certificate of conformity. They also conform to the standards of the BG-Chemie.
Intrinsically safe optical sensors An intrinsically safe circuit must never, neither in normal function nor in abnormal conditions, release sufficient ignition energy which can through - sparks (opening, closing, short circuit, ground contact)
CE labelling
Standards For optical sensors, there are independent, harmonised product standards on both national and international levels. These product standards ensure adherence to the corresponding basic and specific standards.
An important goal of the European Union (EU) is free trade and the standardisation of applicable regulations within EU member countries. To achieve this aim, the European parliament has enacted certain guidelines. 89/392/EWG machine standard 89/336/EWG EMC standard 73/23/EWG
Among other topics, optical sensor functions, construction requirements, pin assignments, temperature ranges, protection classes, electromagnetic compatibility as well as vibration and shock load are described in these standards. The applicable international guideline is the IEC 60947-5-2, for Europe EN 60947-5-2, national (German) VDE 660 part 208.
low voltage standard
If a product falls under one of these guidelines, it must, after a certain period of time, only be placed on the market if it meets the requirements of the respective guideline. The product also has to be marked with the CE label. The CE label certifies the conformity to the applicable standards.
C-UL-US labelling
All listed products are equipped with the CE label.
Products with this label meet the requirements specified by UL (Underwriters Laboratory Inc.) for both the USA as well as Canada. The adherence to the specifications is checked during periodical audits by the UL officials or their representatives.
or - extreme heating of the operating material and conductors
C U L US R cause an ignition of the surrounding explosive atmosphere. Switching amplifiers take over the function of dividing the explosive area and the safe area. The connection to the sensor is done via the NAMURinterface acc. to DIN 19234. The different switching amplifier types differ with respect to operating voltage and output. Via DIP switches the output signal can be inverted (light/dark switching) and wire-break or shortcircuit monitoring can be activated.
Standards and certification
– 27 –
Page 28
Leuze electronic
– 28 –