Page 299
Page 300
Leuze electronic RT 46
Energetic diffuse reflection light scanner Dimensioned drawing
5 … 140mm 10 - 30 V DC l Scanner for detection of PE and glass bottles in single lane conveyors l Large scanning range with optimised beam for secure object detection l Wide voltage range 10 … 30V with PNP switching output l Sensitivity adjustment l AS-interface for optimal adaptation to the application l Common conductor for both power and data reduces installation work l Access to all sensor functions via an ASinterface without additional wiring
We reserve the right to make changes • 46_c01e.fm
ISO 9001
IEC 60947...
A B C D
Indicator diode green Sensitivity adjustment Indicator diode yellow Optical axis
Electrical connection
IP 67
IEC 60947...
Accessories: (available separately • see page 314)
l Mounting systems (BT 46.1, BT 46.1.5, BT 46.2) l M12 connectors (KD …) l Ready-made cables (KB …)
AS-i Accessories: (available separately)
l Bus terminals l AS-i ribbon cables, intermediate cables l Address programming device, coupling modules Leuze electronic GmbH + Co. http://www.leuze.de
Post-box 1111 D-73277 Owen-Teck Tel. ++49 7021 5730
– 300 –
RT 46/44.9-100-S12 - 02 RT 46/A.9-100-S12 - 02
Page 301
Page 302
Leuze electronic RT 46
Mounting and adjustment notes for bottle scanners
RT 46/A.9-100-S12 (AS-i type) and RT 46/44.9-100-S12 (PNP type) Mounting possibilities (as desired, horizontal or vertical) Horizontal Adjustment right
Horizontal Adjustment left
Vertical Adjustment top
Vertical Adjustment bottom
Leuze electronic GmbH + Co. http://www.leuze.de
Post-box 1111 D-73277 Owen-Teck Tel. ++49 7021 5730
– 302 –
RT 46/44.9-100-S12 - 02 RT 46/A.9-100-S12 - 02
Page 303
Leuze electronic RT 46
Gap width adjustment Step 1: Base setting
Step 2: Congestion message check
Step 3: Gap width adjustment
Figure 1
Figure 2
Figure 3
1. Move several sensors past the bottle 1. Position two bottles in front of the sensor 1. Mount sensor acc. to figure 1. without gap. Make sure that no other according to figure 3. 2. Keep distance to bottle in the range objects (e.g. hand) are located in the 2. Create a gap symmetrical to the sensor's 5 … 10mm. scanning area of the sensor or behind centre. Make sure that no other objects 3. Position a single bottle in front of the the bottles. (e.g. hand) are located in the scanning sensor according to figure 1. area of the sensor or behind the bottles. 4. Turn adjustment screw left until indicator 2. Indicator LED must not switch off. 3. The gap width can be changed between 3. The gap width can be changed between LED extinguishes. 0 … 50mm using the adjustment screw. 0 … 50mm using the adjustment screw. 5. Turn adjustment screw right until indicator LED is continuously illuminated. - to enlarge the gap Å turn screw clockwise - to reduce the gap Å turn screw counter-clockwise
RT 46/44.9-100-S12 - 02 RT 46/A.9-100-S12 - 02
- to enlarge the gap Å turn screw clockwise - to reduce the gap Å turn screw counter-clockwise
0202
– 303 –
Page 304
Leuze electronic RT 46
Energetic diffuse reflection light scanner Dimensioned drawing
5 … 250mm 10 - 30 V DC l Scanner for detection of broken packing drums for use in the conveyor technology l Large scanning range with optimised beam for secure object detection l Wide voltage range 10 … 30V with PNP switching output l Sensitivity adjustment
A B C D
We reserve the right to make changes • 46_c02e.fm
ISO 9001
IEC 60947...
Indicator diode green Sensitivity adjustment Indicator diode yellow Optical axis
Electrical connection IP 67
RT 46/44.9-400-S12
IEC 60947...
Accessories: (available separately • see page 314)
l Mounting systems (BT 46.1, BT 46.1.5, BT 46.2) l M12 connectors (KD …) l Ready-made cables (KB …)
Leuze electronic GmbH + Co. http://www.leuze.de
Post-box 1111 D-73277 Owen-Teck Tel. ++49 7021 5730
– 304 –
RT 46/44.9-400-S12 - 01
Page 305
Page 306
Leuze electronic HRT 46
Diffuse reflection light scanner with background suppression Dimensioned drawing
10 … 1000mm 10 - 30 V DC l Adjustable scanner with background suppression l Safe detection of light and dark, as well as inclined or sloped surfaces l Exact scanning range adjustment through multiturn potentiometer l Complementary switching outputs for optimal adaptation to the application l Warning output - for increased availability
We reserve the right to make changes • 46_d01e.fm
ISO 9001
IEC 60947...
A Indicator diode green B Scanning range adjustment C Indicator diode yellow D Optical axis Preferred direction for movement of the test object € + ó IP 67
Electrical connection
IEC 60947...
Accessories: (available separately • see page 314)
l Mounting systems (BT 46.1, BT 46.1.5, BT 46.2) l M12 connectors (KD …) l Ready-made cables (KB …)
Leuze electronic GmbH + Co. http://www.leuze.de
Post-box 1111 D-73277 Owen-Teck Tel. ++49 7021 5730
– 306 –
HRT 46/44-800 (2000)-S12 - 05 IHRT 46/4D-800 (2000)-S12 - 05
Page 307
Page 308
Leuze electronic HRT 46
Diffuse reflection light scanner with background suppression Dimensioned drawing
10 … 1000mm 10 - 30 V DC l Adjustable scanner with background suppression l Safe detection of light and dark, as well as inclined or sloped surfaces l Exact scanning range adjustment through multiturn potentiometer l Complementary switching outputs for optimal adaptation to the application l Warning output - for increased availability
A Indicator diode green B Scanning range adjustment C Indicator diode yellow D Optical axis Preferred direction for movement of the test object € + ó
We reserve the right to make changes • 46_d02e.fm
ISO 9001
IEC 60947...
Electrical connection IP 67
IEC 60947...
Accessories: (available separately • see page 314)
l Mounting systems (BT 46.1, BT 46.1.5, BT 46.2) l M12 connectors (KD …) l Ready-made cables (KB …)
Leuze electronic GmbH + Co. http://www.leuze.de
Post-box 1111 D-73277 Owen-Teck Tel. ++49 7021 5730
– 308 –
HRT 46/44-800, 300-S12 - 06 IHRT 46/4D (…/4…)-800, 300-S12 - 06