Browse
(440) 299-7778
Menu
(440) 299-7778
One-year parts and labor warranty30-day money-back guaranteeEnglishEspañolContact

The text of a manual · part 29 of 105

Catalog: Optical electronic sensors: Cubic Series, pages 269 to 278

Pages 269 to 278 of 1000, from Catalog: Optical electronic sensors

The original document is the PDF (46 MB). This is its text as extracted, unedited; tables and drawings read best in the PDF, and each page heading opens it at that page.

For the Leuze FRK 92, Leuze PRK406 and Leuze PRK 3

Page 269

The text of this page cannot be shown here; see it in the PDF.

Page 270

Leuze electronic RK(R) 97

Energetic diffuse reflection light scanner Dimensioned drawing

2 … 100mm 2 … 200mm 10 - 30 V DC l Energetic scanner with sensitivity adjustment in visible red light or fixed scanning range with infrared light l Small construction with glass cover and robust metal housing for protection against environmental influences l Adjustable sensitivity with high resolution allows optimal adaptation to applications l Connection via M12 connector, plug or cable l Activation input for testing and interlinking A B C

We reserve the right to make changes • 97_c01e.fm

ISO 9001

IEC 60947...

Sensitivity adjustment (only PRK 97/4 150 L) Indicator diode Optical axis

Electrical connection IP 67

IEC 60947...

Accessories: (available separately • see page 274)

l Mounting systems (BT 92, UMS 1, UMS 96-95) l M12 connectors (KD …) l Ready-made cables (KB …)

Leuze electronic GmbH + Co. http://www.leuze.de

Post-box 1111 D-73277 Owen-Teck Tel. ++49 7021 5730

– 270 –

RK 97/…80… - 04 RKR 97/4-150 L - 04

Page 271

The text of this page cannot be shown here; see it in the PDF.

Page 272

Leuze electronic FRKR 97

Diffuse reflection light scanner with background suppression Dimensioned drawing

2 … 150mm 10 - 30 V DC l Scanner with adjustable background suppression l Visible red light for fast and easy alignment l Very good black/white performance, exact adjustment via multiturn potentiometer l Small construction with glass cover and robust metal housing for protection against environmental influences

A B C

We reserve the right to make changes • 97_d01e.fm

ISO 9001

IEC 60947...

Scanning range adjustment Indicator diode Optical axis

Electrical connection IP 67

IEC 60947...

Accessories: (available separately • see page 274)

l Mounting systems (BT 92, UMS 1, UMS 96-95) l M12 connectors (KD …) l Ready-made cables (KB …)

Leuze electronic GmbH + Co. http://www.leuze.de

Post-box 1111 D-73277 Owen-Teck Tel. ++49 7021 5730

– 272 –

FRKR 97/2/4-100 L - 04

Page 273

The text of this page cannot be shown here; see it in the PDF.

Page 274

Accessories

Leuze electronic

97 Series

Accessories

Additional information in section "Accessories" from page 925 onwards!

Reflectors

Dimensioned drawings l Reflectors and reflective tapes are ideally suited for Leuze retro-reflective photoelectric sensors. The performance data refer to the use of Leuze reflectors and reflective tapes. The range of retro-reflective photoelectric sensors depends on the type and size of the reflector. l Adhesive and screw type versions permit universal installation. l Precise optical alignment is not required, as the reflector may be slightly inclined relative to the optical axis. l For retro-reflective photoelectric sensors with polarisation filters, only triad-type reflectors made of plastic or reflective tape No. 2 may be used.

Tape No. 2

We reserve the right to make changes • 97_zu_e.fm

Order codes: Designation

Part No.

TKS 100x100 MTKS 50x50 TKS 30x50 TKS 20x40 Tape 2 KB 450-2000-4 KB 450-2000-4A KB 450-5000-4 KB 450-5000-4A KB 450-10000-4 KB 450-10000-4A KD 095-5 KD 095-5A BT 92 UMS 96-95

500 22816 500 36188 500 23525 500 81283 500 11523 500 80838 500 80841 500 80839 500 80842 500 80840 500 80843 500 20502 500 20501 500 18415 500 80334

Leuze electronic GmbH + Co. http://www.leuze.de

Post-box 1111 D-73277 Owen-Teck Tel. ++49 7021 5730

– 274 –

97 Series Accessories - 05

Page 275

Leuze electronic 97 Series Dimensioned drawings

Connectors, plugs, cables

Selection table

Leuze electronic offers connectors with readymade cables in various lengths suited for the connector-type devices.

Ready-made cables KB 097-2000-4 (2m)

KB 097-6000-4 (6m)

KB 097-12000-4 (12m)

For devices with M12 connectors, there are available: connectors with ready made cables and 2 conductor sockets with screw connection.

M12 connectors with 4-wire cable 2m cable length KB 450-2000-4

Select the appropriate cable for the device with the desired cable length from the following tables.

without cable KD 095-5

KD 095-5A

When ordering throughbeam photoelectric sensors, keep in mind that a connector is required both for the transmitter and receiver.

KB 450-2000-4A

5m cable length KB 450-5000-4

KB 450-5000-4A

Mounting systems

Cable length 10m KB 450-10000-4

KB 450-10000-4A

BT 92

Dimensioned drawings

Sensor

UMS 96-95

97 Series Accessories - 05

0202

– 275 –

Page 276

Leuze electronic

Leuze electronic GmbH + Co. http://www.leuze.de

Post-box 1111 D-73277 Owen-Teck Tel. ++49 7021 5730

– 276 –

Page 277

Leuze electronic

46 Series Overview and advantages Compact sensor series in solid plastic housing

Operating principles: - Throughbeam photoelectric sensors - Protective throughbeam photoelectric sensors - Retro-reflective photoelectric sensors with polarisation filter - Diffuse reflection light scanners with background suppression - Energetic diffuse reflection light scanners

- 10 … 30VDC voltage with PNP transistor output - Alternatively: AS-interface bus connection

Complementary outputs for light/dark switching or as a control function

Connection via M12 connector or cable

- Innovative mounting system for rod mounting or - Mounting holes for screw connection

Options: - Warning output - Activation input

– 277 –

Page 278

Leuze electronic Sensor selection table

LS 46/44-S12

0 … 50m

LS 46/44.8-S12

0 … 50m

LS 46/44, 2000

0 … 50m

LS 46/44.8, 2000

0 … 50m

LS 46/44, 300-S12

0 … 50m

LS 46/44.8, 300-S12

0 … 50m

SLS 46/44.8-S12

0 … 36m

SLS 46/44.8, 2000

0 … 36m

SLS 46/44.8, 300-S12

0 … 36m

LS 46/A-S12

0 … 50m

PRK 46/44-S12

0.3 … 16m

IPRK 46/4-S.12

0.3 … 16m

PRK 46/4.8-S12

0.3 … 16m

PRK 46/44, 2000

0.3 … 16m

IPRK 46/4, 2000

0.3 … 16m

PRK 46/4.8, 2000

0.3 … 16m

PRK 46/44, 300-S12

0.3 … 16m

IPRK 46/4, 300-S12

0.3 … 16m

PRK 46/4.8, 300-S12

0.3 … 16m

PRK 46/44.1-S12

0 … 7m

IPRK 46/4.1-S12

0 … 7m

PRK 46/44.11-S12

0 … 7m

IPRK 46/4.11-S.12

0 … 7m

IPRK 46/4.11, 300-S12

0 … 7m

PRK 46/A-S12

0.3 … 16m

PRK 46/A.1-S12

0 … 7m

RT 46/44.9-100-S12

5 … 140mm

RT 46/A.9-100-S12

5 … 140mm

RT 46/44.9-400-S12

5 … 250mm

HRT 46/44-800-S12

10 … 1000mm

IHRT 46/4D-800-S12

10 … 1000mm

HRT 46/44-800, 2000

10 … 1000mm

IHRT 46/4-800, 2000

10 … 1000mm

HRT 46/44-800, 300-S12

10 … 1000mm

IHRT 46/4D-800, 300-S12

10 … 1000mm

IHRT 46/4-800, 300-S12

10 … 1000mm

HRTR 46/44-500-S12

50 … 600mm

HRTR 46/44-500, 300-S12

50 … 600mm

HRT 46/A-800-S12

10 … 1000mm

• • • • • • • • • •

• • • • • • • • • • • • • • • •

• • • • • • • • • •

• • • • • • • • • • • • • • • •

• • • • • • • • •

Switching frequency

AS-interface

Output

PNP transistor

Operating voltage

AS-i system

Light source

10 … 30VDC

Housing

Infrared

Typ. oper. range limit/ typ. scan. range limit

Red light

Designation

Plastic

Operating principle

• • • • • • • • • •

• • • • • • • • • • • • • •

200Hz 200Hz 200Hz 200Hz 200Hz 200Hz 200Hz 200Hz 200Hz

•

• • • • • • • • • • • • • • • •

200Hz

200Hz 200Hz 200Hz 200Hz 200Hz 200Hz 200Hz 200Hz 200Hz 200Hz 200Hz 200Hz 200Hz 200Hz

• •

200Hz

• • •

• • •

• •

•

200Hz

• • • • • • • • • •

• • • • • • •

• • • • • • • • •

• • • • • • • • •

200Hz

• • •

– 278 –

•

200Hz

•

•

200Hz

•

200Hz

200Hz 200Hz 200Hz 200Hz 200Hz 200Hz 200Hz 200Hz

•

200Hz