Leuze electronic LSR 95

Throughbeam photoelectric sensors Dimensioned drawing

0 … 10m 18 - 30 V DC l Throughbeam photoelectric sensor with high performance reserve in red light l Small construction with glass cover and robust zinc diecast housing, protection class IP 67 for industrial application l Mounting holes and M12 connector for fast installation

A B

We reserve the right to make changes • 95_a02e.fm

ISO 9001

IEC 60947...

Switching indicator yellow Optical axis

Electrical connection IP 67

IEC 60947...

Accessories: (available separately • see page 258)

l Mounting systems (BT 95, UMS 1) l M12 connectors (KD …)

Leuze electronic GmbH + Co. http://www.leuze.de

Post-box 1111 D-73277 Owen-Teck Tel. ++49 7021 5730

– 220 –

LSR 95/4 L - 04

Page 221

The text of this page cannot be shown here; see it in the PDF.

Page 222

Leuze electronic ILSR 95

Throughbeam photoelectric sensors Dimensioned drawing

0 … 18m 10 - 30 V DC l Throughbeam photoelectric sensor with high performance reserve in red light l High switching frequency for detection of fast events l Small construction with glass cover and robust zinc diecast housing, protection class IP 67 for industrial application l Complementary outputs for light/dark switching or as a control function l Very good alignment through wide switching lobe l Sensitivity adjustment for optimal adaptation to the application

We reserve the right to make changes • 95_a05e.fm

A B C D

ISO 9001

IEC 60947...

Sensitivity adjustment Switching indicator yellow Operation indicator green Optical axis

Electrical connection IP 67

IEC 60947...

Accessories: (available separately • see page 258)

l Mounting systems (BT 95, UMS 1) l M12 connectors (KD …)

Leuze electronic GmbH + Co. http://www.leuze.de

Post-box 1111 D-73277 Owen-Teck Tel. ++49 7021 5730

– 222 –

ILSR 95/44.8 L.1 - 02

Page 223

The text of this page cannot be shown here; see it in the PDF.

Page 224

Leuze electronic SLSR 95

Protective throughbeam photoelectric sensors Dimensioned drawing

0 … 10m 10 - 30 V DC

BWS Typ 2

HANNOVER SACHSEN-ANHALT l Protective throughbeam photoelectric sensor with high performance reserve in visible red light l Small construction with glass cover and robust zinc diecast housing, protection class IP 67 for industrial application l Complementary outputs for light/dark switching or as a control function

A B C D

We reserve the right to make changes • 95_a03e.fm

ISO 9001

IEC 60947...

Switching indicator yellow Operation indicator green Transmitter/receiver Optical axis

Electrical connection

IP 67

IEC 60947...

Accessories: (available separately • see page 258)

l Mounting systems (BT 95, UMS 1) l M12 connectors (KD …) l Ready-made cables in straight or angular versions, length 5m (KB …) l Test-monitoring unit: - TNT 32 (Part No. 500 20476) - TNT 33 (Part No. 500 28158) - TNT 34 (Part No. 500 81023) - TNT 35 (Part No. 500 33058) - TMC 66 (Part No. 500 82121) Leuze electronic GmbH + Co. http://www.leuze.de

(1)

For operation with Leuze test-monitoring units, the photoelectric sensor must be connected in light switching mode (pin 4)

Post-box 1111 D-73277 Owen-Teck Tel. ++49 7021 5730

– 224 –

SLSR 95/44.8 L - 03

Page 225

The text of this page cannot be shown here; see it in the PDF.

Page 226

Leuze electronic ILSR 95

Throughbeam photoelectric sensors Dimensioned drawing

0 … 20m l Throughbeam photoelectric sensor with high performance reserve using visible red light for fast and easy alignment l Receiver with integrated AS-i slave - the transmitter needs a separate operating voltage l Small construction with glass cover and robust zinc diecast housing, protection class IP 67 for industrial application

A B C

We reserve the right to make changes • 95_a04e.fm

ISO 9001

IEC 60947...

Switching indicator yellow Operation indicator green Optical axis

Electrical connection IP 67

IEC 60947...

Accessories: (available separately • see page 258)

l Mounting systems (BT 95, UMS 1) l M12 connectors (KD …)

AS-i Accessories: (available separately)

l Bus terminals l AS-i ribbon cable l Address programming device l Coupling modules l Intermediate cables etc. Leuze electronic GmbH + Co. http://www.leuze.de

Post-box 1111 D-73277 Owen-Teck Tel. ++49 7021 5730

– 226 –

ILSR 95/A.8 L - 04

Page 227

The text of this page cannot be shown here; see it in the PDF.

Page 228

Leuze electronic PRK 95

Retro-reflective photoelectric sensors with polarisation filter Dimensioned drawing

0 … 5m 18 - 30 V DC l Polarised retro-reflective photoelectric sensor using visible red light l The autocollimation principle used ensures that the device functions reliably over the entire range (0 … max.) l Polarisation filter blocks unwanted reflections l Small construction with glass cover and robust zinc diecast housing, protection class IP 67 for industrial application l Mounting holes and M12 connector for fast installation

A B

We reserve the right to make changes • 95_b01e.fm

ISO 9001

IEC 60947...

Switching indicator yellow Optical axis

Electrical connection IP 67

IEC 60947...

Accessories: (available separately • see page 258)

l Mounting systems (BT 95, UMS 1) l M12 connectors (KD …) l Reflectors l Reflective tapes

Leuze electronic GmbH + Co. http://www.leuze.de

Post-box 1111 D-73277 Owen-Teck Tel. ++49 7021 5730

– 228 –