Page 189
Page 190
Leuze electronic LVSR 8 Controls and indicators a b c d e f g
Step switch
Switch position Run Switch position + Switch position Teach Switch position Delay Switch position Operation and teach indicator (LED green) Object/light path (LED yellow)
Function
Run
Operating position
Teach
Sensor detects background and object
+
Switching threshold is increased by 5%
-
Switching threshold is reduced by 5%
Delay
Leuze electronic GmbH + Co. http://www.leuze.de
Activation/deactivation of 10ms pulse stretching
Post-box 1111 D-73277 Owen-Teck Tel. ++49 7021 5730
– 190 –
LSVR 8/24 … - 01
Page 191
Leuze electronic LVSR 8 Teach-in Step switch
Scanning operation
Throughbeam operation
LED green
LED yellow
Normal operation
Run
Operating position
Operating position
ON
Q
Activated
Run -> Teach
Immediately
Immediately
OFF
OFF
Time lock
Teach
> 2s
> 2s
3Hz
OFF
Teaching phase 1
Teach
Accept value 1 (background) Accept value 1 (free light path)
3Hz
OFF
Teaching phase 2
Teach -> Run
Accept value 2 (object)
Accept value 2 (object)
3Hz
OFF
Normal operation
Run
Operating position
Operating position
ON
Q
The step switch must be set to >500ms to allow the individual functions to be activated.
Changing the switching threshold Step switch
Scanning operation
Throughbeam operation
LED green
LED yellow
Normal operation
Run
Operating position
Operating position
ON
Q
Activated
Run -> (+/-)
Immediately
Immediately
OFF
OFF
Time lock
(+/-)
> 2s
> 2s
1Hz
Q
Change
(+/-)
Switching threshold (increase/decrease)
Switching threshold (increase/decrease)
1Hz
Q
Normal operation
(+/-) -> Run
Operating position
Operating position
ON
Q
At switch position (+/-), the switching threshold is increased by 5% every second. Maximum value LED green = ON Minimum value LED green = OFF
Pulse stretching on/off Step switch
Scanning operation
Throughbeam operation
LED green
LED yellow
Normal operation
Run
Operating position
Operating position
ON
Q
Activated
Run -> Delay
Immediately
Immediately
OFF
OFF
Time lock
Delay
> 2s
> 2s
10Hz
Status
Change
Delay
> 10s pulse stretching On <-> Off
Pulse stretching On <-> Off
10Hz
New
Normal operation
Delay -> Run
Operating position
Operating position
ON
Q
LSVR 8/24 … - 01
0202
– 191 –
Page 192
Leuze electronic KRTG 8
Green light contrast scanner Dimensioned drawing
10mm 10 - 30 V DC
10 kHz l Static teach-in procedure l Switching frequency 10,000 Hz l Green transmission LED l M12 turning connector
We reserve the right to make changes • 8_e02e.fm
ISO 9001
A B C D E F G
Transmitter Receiver Optical axis Operational control LED green LED yellow 90° turning connector
IP 67
Electrical connection IEC 60947...
IEC 60947...
Accessories: (available separately • see page 196)
l M12 connectors (KD …) l Cable (KB …) l Mounting systems
Leuze electronic GmbH + Co. http://www.leuze.de
Post-box 1111 D-73277 Owen-Teck Tel. ++49 7021 5730
– 192 –
KRTG 8/24 … - 01
Page 193
Page 194
Leuze electronic KRTG 8 Controls and indicators a b c d e f g
Step switch
Switch position Run Switch position + Switch position Teach Switch position Delay Switch position Operation and teach indicator (LED green) Object/light path (LED yellow)
Function
Run
Teach and Run position for marker contrast
Teach
Teach position for background contrast
+
Switching threshold is increased by +5%
-
Switching threshold is reduced by -5%
Delay
Activate/deactivate 10ms pulse stretching
The step switch must be set to > 1s to allow the individual functions to be activated.
Signal propagation Label Switch position Teach Switch position Run LED yellow Switching output with light switching
Leuze electronic GmbH + Co. http://www.leuze.de
Post-box 1111 D-73277 Owen-Teck Tel. ++49 7021 5730
– 194 –
KRTG 8/24 … - 01
Page 195
Leuze electronic KRTG 8 Teach procedure for statical teach-in Operation
Transmitter
LED green LED yellow
1
Position the light spot on the background
Green light spot visible
ON
ON/OFF
2
Switch the step switch from Run -> Teach
Green light spot visible
3Hz
OFF
3
Position the light spot on the marker
Green light spot visible
3Hz
OFF
4
Switch the step switch from Teach -> Run
Green light spot visible
3Hz
OFF
Teach-in successful
Green light spot visible
ON
ON
Teach-in error
Green light spot flashes with 3Hz OFF
3Hz
The step switch must be set to > 1s to allow the individual functions to be activated.
Changing the switching threshold Operation
Transmitter
LED green LED yellow
1
Step switch in position Run
Green light spot visible
ON
ON/OFF
2
Switch the step switch from Run -> (+/-)
Green light spot visible
OFF
OFF
3
Sensitivity is changed in steps of 5% each
Green light spot visible
1Hz
OFF
4
Switch the step switch from (+/-) -> Run
Green light spot visible
ON
ON/OFF
In switch position (+), the switching threshold is increased by 5% every second. In switch position (-), the switching threshold is increased by 5% every second. Modification of switching threshold activated:green LED = 1Hz Maximum value switching threshold reached:LED green = ON Minimum value switching threshold reached:LED green = OFF
Pulse stretching on/off Operation
Transmitter
LED green LED yellow
1
Step switch in position Run
Green light spot visible
ON
ON/OFF
2
Switch the step switch from Run -> Delay
Green light spot visible
OFF
ON/OFF
3
Status display of the pulse stretching
Green light spot OFF
10Hz
Status display: ON=Delay active OFF=Delay not active
4
10s waiting time before switching After 10s delay value modified
Green light spot OFF
10Hz
Status display: ON=Delay active OFF=Delay not active
5
Switch the step switch from Delay -> Run
Green light spot visible
ON
ON/OFF
KRTG 8/24 … - 01
0208
– 195 –
Page 196
Accessories
Leuze electronic
8 Series
Accessories
Additional information in section "Accessories" from page 925 onwards!
Reflectors
Dimensioned drawings l Reflectors and reflective tapes are ideally suited for Leuze retro-reflective photoelectric sensors. The performance data refer to the use of Leuze reflectors and reflective tapes. The range of retro-reflective photoelectric sensors depends on the type and size of the reflector. l Adhesive and screw type versions permit universal installation. l Precise optical alignment is not required, as the reflector may be slightly inclined relative to the optical axis. l For retro-reflective photoelectric sensors with polarisation filters, only triad-type reflectors made of plastic or reflective tape No. 2 may be used.
Tape No. 2
We reserve the right to make changes • 8_zu_e.fm
Order codes: Designation
Part No.
TKS 100x100 MTKS 50x50 TKS 30x50 TKS 20x40 Tape 2 KB 095-5000-5 KB 095-5000-5A KB 450-2000-4 KB 450-2000-4A KB 450-5000-4 KB 450-5000-4A KB 450-10000-4 KB 450-10000-4A KD 095-5 KD 095-5A
500 22816 500 36188 500 23525 500 81283 500 11523 500 20500 500 20499 500 80838 500 80841 500 80839 500 80842 500 80840 500 80843 500 20502 500 20501
Leuze electronic GmbH + Co. http://www.leuze.de
Post-box 1111 D-73277 Owen-Teck Tel. ++49 7021 5730
– 196 –
8 Series Accessories - 01
Page 197
Leuze electronic 8 Series Dimensioned drawings
Connectors, plugs, cables
There are 2 connectors available for devices with M12 connectors: angled or straight, with and without cable. Protection class (DIN 40050) plugged and screwed: IP 67
Selection table M12 connectors with cable M12
KB 095-5000-5
KB 095-5000-5A
M12
KB 450-2000-4
KB 450-2000-4A
M12
KB 450-5000-4
KB 450-5000-4A
M12
KB 450-10000-4
KB 450-10000-4A
Important: With throughbeam photoelectric sensors, a connector is required both for the transmitter and the receiver. without cable
KD 095-5
KD 095-5A
Dimensioned drawings BT 8-0
Mounting systems BT 8-0 (Part No. 500 36196)
BT 8
BT 8 (Part No. 500 36195)
8 Series Accessories - 01
0202
– 197 –
Page 198
Leuze electronic 8 Series Mounting systems
Dimensioned drawings UMS 8-D…
UMS 8.1-D…
UMS 8-D10 (Ø10mm, Part No. 500 35020) UMS 8-D12 (Ø12mm, Part No. 500 35021) UMS 8-D14 (Ø14mm, Part No. 500 35022)
UMS 8.1-D10 (Ø10mm, Part No. 500 35023) UMS 8.1-D12 (Ø12mm, Part No. 500 35024) UMS 8.1-D14 (Ø14mm, Part No. 500 35025)
A B C
Clamp Rod Sensor
A B C D E
UMS 8.2-D10 (Ø10mm, Part No. 500 35026) UMS 8.2-D12 (Ø12mm, Part No. 500 35027) UMS 8.2-D14 (Ø14mm, Part No. 500 35028)
Mount Joint Clamp Rod Sensor
UMS 8.2-D…
BT 8-ARH
BT 8-ARH (Part No. 500 35030)
A B C D E Leuze electronic GmbH + Co. http://www.leuze.de
Mount Joint Clamp Rod Sensor
Post-box 1111 D-73277 Owen-Teck Tel. ++49 7021 5730
– 198 –
8 Series Accessories - 01