Browse
(440) 299-7778
Menu
(440) 299-7778
One-year parts and labor warranty30-day money-back guaranteeEnglishEspañolContact

The text of a manual · part 21 of 105

Catalog: Optical electronic sensors: Cubic Series, pages 189 to 198

Pages 189 to 198 of 1000, from Catalog: Optical electronic sensors

The original document is the PDF (46 MB). This is its text as extracted, unedited; tables and drawings read best in the PDF, and each page heading opens it at that page.

For the Leuze FRK 92, Leuze PRK406 and Leuze PRK 3

Page 189

The text of this page cannot be shown here; see it in the PDF.

Page 190

Leuze electronic LVSR 8 Controls and indicators a b c d e f g

Step switch

Switch position Run Switch position + Switch position Teach Switch position Delay Switch position Operation and teach indicator (LED green) Object/light path (LED yellow)

Function

Run

Operating position

Teach

Sensor detects background and object

+

Switching threshold is increased by 5%

-

Switching threshold is reduced by 5%

Delay

Leuze electronic GmbH + Co. http://www.leuze.de

Activation/deactivation of 10ms pulse stretching

Post-box 1111 D-73277 Owen-Teck Tel. ++49 7021 5730

– 190 –

LSVR 8/24 … - 01

Page 191

Leuze electronic LVSR 8 Teach-in Step switch

Scanning operation

Throughbeam operation

LED green

LED yellow

Normal operation

Run

Operating position

Operating position

ON

Q

Activated

Run -> Teach

Immediately

Immediately

OFF

OFF

Time lock

Teach

> 2s

> 2s

3Hz

OFF

Teaching phase 1

Teach

Accept value 1 (background) Accept value 1 (free light path)

3Hz

OFF

Teaching phase 2

Teach -> Run

Accept value 2 (object)

Accept value 2 (object)

3Hz

OFF

Normal operation

Run

Operating position

Operating position

ON

Q

The step switch must be set to >500ms to allow the individual functions to be activated.

Changing the switching threshold Step switch

Scanning operation

Throughbeam operation

LED green

LED yellow

Normal operation

Run

Operating position

Operating position

ON

Q

Activated

Run -> (+/-)

Immediately

Immediately

OFF

OFF

Time lock

(+/-)

> 2s

> 2s

1Hz

Q

Change

(+/-)

Switching threshold (increase/decrease)

Switching threshold (increase/decrease)

1Hz

Q

Normal operation

(+/-) -> Run

Operating position

Operating position

ON

Q

At switch position (+/-), the switching threshold is increased by 5% every second. Maximum value LED green = ON Minimum value LED green = OFF

Pulse stretching on/off Step switch

Scanning operation

Throughbeam operation

LED green

LED yellow

Normal operation

Run

Operating position

Operating position

ON

Q

Activated

Run -> Delay

Immediately

Immediately

OFF

OFF

Time lock

Delay

> 2s

> 2s

10Hz

Status

Change

Delay

> 10s pulse stretching On <-> Off

Pulse stretching On <-> Off

10Hz

New

Normal operation

Delay -> Run

Operating position

Operating position

ON

Q

LSVR 8/24 … - 01

0202

– 191 –

Page 192

Leuze electronic KRTG 8

Green light contrast scanner Dimensioned drawing

10mm 10 - 30 V DC

10 kHz l Static teach-in procedure l Switching frequency 10,000 Hz l Green transmission LED l M12 turning connector

We reserve the right to make changes • 8_e02e.fm

ISO 9001

A B C D E F G

Transmitter Receiver Optical axis Operational control LED green LED yellow 90° turning connector

IP 67

Electrical connection IEC 60947...

IEC 60947...

Accessories: (available separately • see page 196)

l M12 connectors (KD …) l Cable (KB …) l Mounting systems

Leuze electronic GmbH + Co. http://www.leuze.de

Post-box 1111 D-73277 Owen-Teck Tel. ++49 7021 5730

– 192 –

KRTG 8/24 … - 01

Page 193

The text of this page cannot be shown here; see it in the PDF.

Page 194

Leuze electronic KRTG 8 Controls and indicators a b c d e f g

Step switch

Switch position Run Switch position + Switch position Teach Switch position Delay Switch position Operation and teach indicator (LED green) Object/light path (LED yellow)

Function

Run

Teach and Run position for marker contrast

Teach

Teach position for background contrast

+

Switching threshold is increased by +5%

-

Switching threshold is reduced by -5%

Delay

Activate/deactivate 10ms pulse stretching

The step switch must be set to > 1s to allow the individual functions to be activated.

Signal propagation Label Switch position Teach Switch position Run LED yellow Switching output with light switching

Leuze electronic GmbH + Co. http://www.leuze.de

Post-box 1111 D-73277 Owen-Teck Tel. ++49 7021 5730

– 194 –

KRTG 8/24 … - 01

Page 195

Leuze electronic KRTG 8 Teach procedure for statical teach-in Operation

Transmitter

LED green LED yellow

1

Position the light spot on the background

Green light spot visible

ON

ON/OFF

2

Switch the step switch from Run -> Teach

Green light spot visible

3Hz

OFF

3

Position the light spot on the marker

Green light spot visible

3Hz

OFF

4

Switch the step switch from Teach -> Run

Green light spot visible

3Hz

OFF

Teach-in successful

Green light spot visible

ON

ON

Teach-in error

Green light spot flashes with 3Hz OFF

3Hz

The step switch must be set to > 1s to allow the individual functions to be activated.

Changing the switching threshold Operation

Transmitter

LED green LED yellow

1

Step switch in position Run

Green light spot visible

ON

ON/OFF

2

Switch the step switch from Run -> (+/-)

Green light spot visible

OFF

OFF

3

Sensitivity is changed in steps of 5% each

Green light spot visible

1Hz

OFF

4

Switch the step switch from (+/-) -> Run

Green light spot visible

ON

ON/OFF

In switch position (+), the switching threshold is increased by 5% every second. In switch position (-), the switching threshold is increased by 5% every second. Modification of switching threshold activated:green LED = 1Hz Maximum value switching threshold reached:LED green = ON Minimum value switching threshold reached:LED green = OFF

Pulse stretching on/off Operation

Transmitter

LED green LED yellow

1

Step switch in position Run

Green light spot visible

ON

ON/OFF

2

Switch the step switch from Run -> Delay

Green light spot visible

OFF

ON/OFF

3

Status display of the pulse stretching

Green light spot OFF

10Hz

Status display: ON=Delay active OFF=Delay not active

4

10s waiting time before switching After 10s delay value modified

Green light spot OFF

10Hz

Status display: ON=Delay active OFF=Delay not active

5

Switch the step switch from Delay -> Run

Green light spot visible

ON

ON/OFF

KRTG 8/24 … - 01

0208

– 195 –

Page 196

Accessories

Leuze electronic

8 Series

Accessories

Additional information in section "Accessories" from page 925 onwards!

Reflectors

Dimensioned drawings l Reflectors and reflective tapes are ideally suited for Leuze retro-reflective photoelectric sensors. The performance data refer to the use of Leuze reflectors and reflective tapes. The range of retro-reflective photoelectric sensors depends on the type and size of the reflector. l Adhesive and screw type versions permit universal installation. l Precise optical alignment is not required, as the reflector may be slightly inclined relative to the optical axis. l For retro-reflective photoelectric sensors with polarisation filters, only triad-type reflectors made of plastic or reflective tape No. 2 may be used.

Tape No. 2

We reserve the right to make changes • 8_zu_e.fm

Order codes: Designation

Part No.

TKS 100x100 MTKS 50x50 TKS 30x50 TKS 20x40 Tape 2 KB 095-5000-5 KB 095-5000-5A KB 450-2000-4 KB 450-2000-4A KB 450-5000-4 KB 450-5000-4A KB 450-10000-4 KB 450-10000-4A KD 095-5 KD 095-5A

500 22816 500 36188 500 23525 500 81283 500 11523 500 20500 500 20499 500 80838 500 80841 500 80839 500 80842 500 80840 500 80843 500 20502 500 20501

Leuze electronic GmbH + Co. http://www.leuze.de

Post-box 1111 D-73277 Owen-Teck Tel. ++49 7021 5730

– 196 –

8 Series Accessories - 01

Page 197

Leuze electronic 8 Series Dimensioned drawings

Connectors, plugs, cables

There are 2 connectors available for devices with M12 connectors: angled or straight, with and without cable. Protection class (DIN 40050) plugged and screwed: IP 67

Selection table M12 connectors with cable M12

KB 095-5000-5

KB 095-5000-5A

M12

KB 450-2000-4

KB 450-2000-4A

M12

KB 450-5000-4

KB 450-5000-4A

M12

KB 450-10000-4

KB 450-10000-4A

Important: With throughbeam photoelectric sensors, a connector is required both for the transmitter and the receiver. without cable

KD 095-5

KD 095-5A

Dimensioned drawings BT 8-0

Mounting systems BT 8-0 (Part No. 500 36196)

BT 8

BT 8 (Part No. 500 36195)

8 Series Accessories - 01

0202

– 197 –

Page 198

Leuze electronic 8 Series Mounting systems

Dimensioned drawings UMS 8-D…

UMS 8.1-D…

UMS 8-D10 (Ø10mm, Part No. 500 35020) UMS 8-D12 (Ø12mm, Part No. 500 35021) UMS 8-D14 (Ø14mm, Part No. 500 35022)

UMS 8.1-D10 (Ø10mm, Part No. 500 35023) UMS 8.1-D12 (Ø12mm, Part No. 500 35024) UMS 8.1-D14 (Ø14mm, Part No. 500 35025)

A B C

Clamp Rod Sensor

A B C D E

UMS 8.2-D10 (Ø10mm, Part No. 500 35026) UMS 8.2-D12 (Ø12mm, Part No. 500 35027) UMS 8.2-D14 (Ø14mm, Part No. 500 35028)

Mount Joint Clamp Rod Sensor

UMS 8.2-D…

BT 8-ARH

BT 8-ARH (Part No. 500 35030)

A B C D E Leuze electronic GmbH + Co. http://www.leuze.de

Mount Joint Clamp Rod Sensor

Post-box 1111 D-73277 Owen-Teck Tel. ++49 7021 5730

– 198 –

8 Series Accessories - 01