Browse
(440) 299-7778
Menu
(440) 299-7778
One-year parts and labor warranty30-day money-back guaranteeEnglishEspañolContact

The text of a manual · part 19 of 105

Catalog: Optical electronic sensors: Cubic Series, pages 169 to 178

Pages 169 to 178 of 1000, from Catalog: Optical electronic sensors

The original document is the PDF (46 MB). This is its text as extracted, unedited; tables and drawings read best in the PDF, and each page heading opens it at that page.

For the Leuze FRK 92, Leuze PRK406 and Leuze PRK 3

Page 169

The text of this page cannot be shown here; see it in the PDF.

Page 170

Leuze electronic PRK 8

Retro-reflective photoelectric sensors Dimensioned drawing

0 … 2.4m

1,5 kHz

10 - 30 V DC l Detection of transparent media (e. g. clear glass, PE, foil) l The autocollimation principle used ensures that the device functions reliably over the entire range (0 … max.) l Push-pull switching outputs l M12 turning connector l Visible red light l Square light spot

A B C D E

We reserve the right to make changes • 8_b03e.fm

ISO 9001

Transmitter/receiver Optical axis Operational control LED yellow 90° turning connector

IP 67

Electrical connection IEC 60947...

IEC 60947...

Accessories: (available separately • see page 196)

l M12 connectors (KD …) l Cable (KB …) l Mounting systems l Reflectors l Reflective tapes

Leuze electronic GmbH + Co. http://www.leuze.de

Post-box 1111 D-73277 Owen-Teck Tel. ++49 7021 5730

– 170 –

PRK 8/66.41-S12 - 01

Page 171

The text of this page cannot be shown here; see it in the PDF.

Page 172

Leuze electronic PRK 8

Retro-reflective photoelectric sensors with Tracking function Dimensioned drawing

0 … 2.4m

1 kHz

10 - 30 V DC

Tracking PET Glas l Detection of transparent media (e. g. clear glass, PE, foil) l Automatic contamination compensation (tracking function) for longer intervals between cleanings l The autocollimation principle used ensures that the device functions reliably over the entire range (0 … max.) l Push-pull switching outputs l M12 turning connector l Visible red light

We reserve the right to make changes • 8_b05e.fm

ISO 9001

A B C D E

Receiver Optical axis Operational control LED yellow, LED green 90° turning connector

IP 67

Electrical connection IEC 60947...

IEC 60947...

Accessories: (available separately • see page 196)

l M12 connectors (KD …) l Cable (KB …) l Mounting systems l Reflectors l Reflective tapes

Leuze electronic GmbH + Co. http://www.leuze.de

Post-box 1111 D-73277 Owen-Teck Tel. ++49 7021 5730

– 172 –

PRK 8/66.42-S12 - 01

Page 173

The text of this page cannot be shown here; see it in the PDF.

Page 174

Leuze electronic PRK 8 1. Operating principle of contamination compensation (tracking function) This transparency sensor (clear-glass sensor) is a device which automatically compensates system contamination at the reflector and sensor by means of continuous measurement of the receiving level. The control rate depends on the number of gaps in the process. This tracking function increases the interval between cleaning sessions considerably. The sensor does not need to be recalibrated after the system has been cleaned. In typical applications, cleaning can be performed during system operation. This means higher system efficiency. The system is calibrated ("teach-in") once only at initial setup. The appropriate object is then selected (PE, clear glass or coloured glass). The "teach-in" process does not have to be performed again if a different object is selected.

2. Controls and indicators a b c d e f g

Switch position 2 (clear-glass bottle) Switch position 1 (PE bottle, glass pane, foil) Switch position, Teach Switch position, Tracking ON/OFF Switch position 3 (coloured-glass bottle) Operation and teach indicator (LED green) Light path free (LED yellow)

3. Adjustment procedure (teach-in) via step switch Correct adjustment procedure:

Important to note:

1. There must be no objects in the beam The Teach-in procedure must be path between the retro-reflective photoe- conducted without any objects ! lectric sensor and the reflector during the adjustment procedure.

Reflector STO

P

Retro-reflectivephotoelectric sensor

Important during teach-in: free light path!

2. Align the sensor with the reflector so that The beam must not fall outside the the beam is visible in the middle of the reflector area. The mounted reflector should always be larger than the visible reflector beam!

3. Turn the step switch to the "Teach" posi- The adjustment procedure must be conducted without objects! tion for about 2s. 4. Turn the step switch back to positions 1, 2 or 3.

see 3.)

see 4.)

Leuze electronic GmbH + Co. http://www.leuze.de

5. To turn the tracking function on/off, turn The step switch must be turned to the step switch to "Auto" for about 2s. positions 1, 2 or 3 during operation! 6. Turn the step switch back to positions 1, 2 or 3.

Post-box 1111 D-73277 Owen-Teck Tel. ++49 7021 5730

– 174 –

PRK 8/66.42-S12 - 01

Page 175

Leuze electronic PRK 8 4. Setting operating mode Object to be identified

Material, e.g.:

€Transparent objects l PE bottle l PEN bottle l Clear plate glass l Foil

1. Turn the step switch to the "Teach" position for about 2s. 2. Turn the step switch back to position 1 l Clear glass bottle l Coloured plate glass

1. Turn the step switch to the "Teach" position for about 2s. 2. Turn the step switch back to position 2

óLess transparent objects

Switch position

Correct adjustment procedure:

Tracking can be turned on or off by switching to "Auto"

Tracking can be turned on or off by switching to "Auto"

ìOpaque objects l Coloured glass bottle l Opaque objects

1. Turn the step switch to the "Teach" position for about 2s. 2. Turn the step switch back to position 3 Tracking can be turned on or off by switching to "Auto"

5. Calibration procedure (teach-in) by wire 1. Set step switch to desired operating mode (PE, clear-glass or coloured-glass bottle). 2. Activate teach-in wire (pin 5) (high active). Teach-in procedure takes max. 1s. 3. Deactivate teach-in wire (pin 5).

6. LED functions LED colour LED green

LED yellow

Function

Active in switch position

ON

Tracking ON

1, 2, 3

OFF

Tracking OFF

1, 2, 3

Flashing

Teach-in is running

Teach

ON

Light path free

1, 2, 3

OFF

Light path interrupted

1, 2, 3

Flashing

Uncertain detection

1, 2, 3

PRK 8/66.42-S12 - 01

0202

– 175 –

Page 176

Leuze electronic PRKL 8

Laser retro-reflective photoelectric sensor Dimensioned drawing

0 … 21m

2,8 kHz

10 - 30 V DC

A2 LS l Laser, red light l The autocollimation principle used ensures that the device functions reliably over the entire range (0 … max.) l A²LS - active suppression of extraneous light l Adjustable focus l M12 turning connector or cable connection

A B C D E

We reserve the right to make changes • 8_b02e.fm

ISO 9001

Transmitter and receiver Optical axis Operational control LED yellow 90° turning connector

IP 67

Electrical connection IEC 60947...

IEC 60947...

Accessories: (available separately • see page 196)

l M12 connectors (KD …) l Cable (KB …) l Mounting systems l Reflectors l Reflective tapes

Leuze electronic GmbH + Co. http://www.leuze.de

Post-box 1111 D-73277 Owen-Teck Tel. ++49 7021 5730

– 176 –

PRKL 8/24 … - 01

Page 177

The text of this page cannot be shown here; see it in the PDF.

Page 178

Leuze electronic RTR 8

Energetic diffuse reflection light scanner Dimensioned drawing

5 … 800mm

1,5 kHz

10 - 30 V DC

A2 LS l A²LS - active suppression of extraneous light l Push-pull switching outputs l M12 turning connector or cable connection l Visible red light

A B C D E F

We reserve the right to make changes • 8_c01e.fm

ISO 9001

IEC 60947...

Receiver Transmitter Optical axis Operational control LED yellow 90° turning connector

Electrical connection IP 67

IEC 60947...

Accessories: (available separately • see page 196)

l M12 connectors (KD …) l Cable (KB …) l Mounting systems

Leuze electronic GmbH + Co. http://www.leuze.de

Post-box 1111 D-73277 Owen-Teck Tel. ++49 7021 5730

– 178 –

RTR 8/66-800 … - 01 RTR 8/44-800 … - 01