Browse
(440) 299-7778
Menu
(440) 299-7778
One-year parts and labor warranty30-day money-back guaranteeEnglishEspañolContact

The text of a manual · part 17 of 105

Catalog: Optical electronic sensors: Cubic Series, pages 149 to 158

Pages 149 to 158 of 1000, from Catalog: Optical electronic sensors

The original document is the PDF (46 MB). This is its text as extracted, unedited; tables and drawings read best in the PDF, and each page heading opens it at that page.

For the Leuze FRK 92, Leuze PRK406 and Leuze PRK 3

Page 149

The text of this page cannot be shown here; see it in the PDF.

Page 150

Leuze electronic IPRK 18

Retro-reflective photoelectric sensors with polarisation filter Dimensioned drawing

0 … 4m 10 - 30 V DC

Tracking PET Glas l Intelligent sensor for detection of transparent objects (e.g. clear glass, PE, foil) l Automatic contamination compensation (tracking function) for longer intervals between cleanings l Adjustment via teach-in

A B C

We reserve the right to make changes • 18_b05e.fm

ISO 9001

IEC 60947...

Step switch for object adjustment Indicator diodes Optical axis

Electrical connection IP 67

IEC 60947...

Accessories: (available separately • see page 156)

l Mounting system (BT 95) l M12 connectors (KD …) l Reflectors

PRK 18/24 DL.46 PRK 18/24 DL.42 IPRK 18/4 DL.41 IPRK 18/2 DL.41 PRK 18/44 L.44 Leuze electronic GmbH + Co. http://www.leuze.de

PIN 1 + + + + +

PIN 2 NPN NPN Warn Warn PNP

PIN 3 GND GND GND GND GND

Post-box 1111 D-73277 Owen-Teck Tel. ++49 7021 5730

– 150 –

PIN 4 PNP PNP PNP NPN PNP

PIN 5 L/D Teach L/D L/D Teach IPRK 18… - 01 PRK 18/24… - 01

Page 151

The text of this page cannot be shown here; see it in the PDF.

Page 152

Leuze electronic IPRK 18 1. Operating principle of contamination compensation (tracking function) This transparency sensor (clear-glass sensor) is a device which automatically compensates system contamination at the reflector and sensor by means of continuous measurement of the receiving level. The control rate depends on the number of gaps in the process. This tracking function increases the interval between cleaning sessions considerably. The control limit is indicated by a warning output. The sensor does not need to be recalibrated after the system has been cleaned. In typical applications, cleaning can be performed during system operation. This means higher system efficiency. The system is calibrated ("teach-in") once only at initial setup. The appropriate object is then selected (PE, clear glass or coloured glass). The "teach-in" process does not have to be performed again if a different object is selected.

2. Controls and indicators a b c d e f g h

Light path free (LED1 yellow) Operation and teach indicator (LED green/red) Tracking ON (LED2 yellow) Switch position tracking Switch position 3 (coloured-glass bottle) Switch position 2 (clear-glass bottle) Switch position 1 (PE bottle, glass pane, foil) Switch position Teach

3. Adjustment procedure (teach-in) via step switch Correct adjustment procedure:

Important to note:

1. There must be no objects in the beam The Teach-in procedure must be path between the retro-reflective photoe- conducted without any objects ! lectric sensor and the reflector during the adjustment procedure.

Reflector STO

P

Retro-reflectivephotoelectric sensor

Important during teach-in: free light path!

2. Align the sensor with the reflector so that The beam must not fall outside the the beam is visible in the middle of the reflector area. The mounted reflector should always be larger than the visible reflector beam!

3. Turn the step switch to the "Teach" The adjustment procedure must be conducted without objects! position for about 2s. 4. Turn the step switch back to positions 1, 2 or 3.

see 3.) see 4.)

Leuze electronic GmbH + Co. http://www.leuze.de

5. To turn the tracking function on/off, turn The step switch must be turned to the step switch to "Auto" for about 2s. positions 1, 2 or 3 during operation! 6. Turn the step switch back to positions 1, 2 or 3.

Post-box 1111 D-73277 Owen-Teck Tel. ++49 7021 5730

– 152 –

IPRK 18… - 01 PRK 18/24… - 01

Page 153

Leuze electronic IPRK 18 4. Setting operating mode Object to be identified

Material, e.g.:

€Transparent objects l PE bottle l PEN bottle l Clear plate glass l Foil

óLess transparent objects

Switch position

Correct adjustment procedure:

1

Teach

1. Turn the step switch to the "Teach" position for about 2s. 2. Turn the step switch back to position 1

3

Auto

Tracking can be turned on or off by switching to "Auto"

2 l Clear glass bottle l Coloured plate glass

1

Teach

3

Auto

2

ìOpaque objects l Coloured glass bottle l Opaque objects

1

Teach

3

Auto

2

1. Turn the step switch to the "Teach" position for about 2s. 2. Turn the step switch back to position 2 Tracking can be turned on or off by switching to "Auto"

1. Turn the step switch to the "Teach" position for about 2s. 2. Turn the step switch back to position 3 Tracking can be turned on or off by switching to "Auto"

5. Calibration procedure (teach-in) by wire 1. Set step switch to desired operating mode (PE, clear-glass or coloured-glass bottle). 2. Activate teach-in wire (pin 5) (high active). Teach-in procedure takes max. 1s. 3. Deactivate teach-in wire (pin 5).

6. Preferred types

Switching outputs

Function characteristics Adjustment Options

PE clear glass coloured glass 2 PNP transistors 2 NPN transistors 1 NPN + 1 PNP transistor complementary light switching dark switching step switch contamination compensation (step tracking) cleaning compensation (peak tracking) tracking ON/OFF warning output teach-in via step-switch teach-in via control line light/dark commutation via control line

IPRK 18… - 01 PRK 18/24… - 01

PRK 18/44 L.44 Part No. 500 61251

Application

IPRK 18/2 DL.41 Part No. 500 33553

Equipment Ï

IPRK 18/4 DL.41 Part No. 500 33552

Order codeÍ

PRK 18/24 DL.42 Part No. 500 33554

Selection table

PRK 18/24 DL.46 Part No. 500 32798 l l l l l l l l l l l l l l l l l l l l l l l l l l l l l l l l l l l l l l l l l l l l l l l l l l l l l l l l l l l l l

0202

– 153 –

Page 154

Leuze electronic IPRK 18

Retro-reflective photoelectric sensors with polarisation filter Dimensioned drawing

0 … 3m l Polarised retro-reflective photoelectric sensor using visible red light for safe detection of transparent media (e.g. clear glass, PE, foil) with integrated AS-i slave l Selection of the detection range via AS-i profile (e.g. from clear glass to coloured glass or non transparent media) without new user access l Gap detection ˜ 5mm (see table) l Warning function autoControl for increased availability and for checking of the correct base setting l Extended switching pulse for reliable transmission via AS-interface

Minimum switching pulse for IPRK 18/A.1 L.4 Object D0 for P1=0 D0 for P1=1

A B C

We reserve the right to make changes • 18_b04e.fm

ISO 9001

IEC 60947...

Indicator diode Sensitivity adjustment Optical axis

Electrical connection IP 67

IEC 60947...

Accessories: (available separately • see page 156)

l Mounting system (BT 95) l M12 connectors (KD …) l M8 connectors (KD …) l Reflectors l Reflective tapes

Leuze electronic GmbH + Co. http://www.leuze.de

Post-box 1111 D-73277 Owen-Teck Tel. ++49 7021 5730

– 154 –

IPRK 18/A L.4 - 02

Page 155

The text of this page cannot be shown here; see it in the PDF.

Page 156

Accessories

Leuze electronic

18 Series

Accessories

Additional information in section "Accessories" from page 925 onwards!

Reflectors

Dimensioned drawings l Reflectors and reflective tapes are ideally suited for Leuze retro-reflective photoelectric sensors. The performance data refer to the use of Leuze reflectors and reflective tapes. The range of retro-reflective photoelectric sensors depends on the type and size of the reflector. l Adhesive and screw type versions permit universal installation. l Precise optical alignment is not required, as the reflector may be slightly inclined relative to the optical axis. l For retro-reflective photoelectric sensors with polarisation filters, only triad-type reflectors made of plastic or reflective tape No. 2 may be used.

Tape No. 2

We reserve the right to make changes • 18_zu_e.fm

Order codes: Designation

Part No.

TKS 100x100 MTKS 50x50 TKS 30x50 TKS 20x40 Tape 2 KB 095-5000-5 KB 095-5000-5A KD 095-5 KD 095-5A BT 95 US 18

500 22816 500 36188 500 23525 500 81283 500 11523 500 20500 500 20499 500 20502 500 20501 500 20833 500 80987

Leuze electronic GmbH + Co. http://www.leuze.de

Post-box 1111 D-73277 Owen-Teck Tel. ++49 7021 5730

– 156 –

18 Series Accessories - 03

Page 157

Leuze electronic 18 Series Dimensioned drawings

M12 connectors

For devices with M12 connectors, there are available: connectors with ready-made 5m cable and 2 connectors with screw connection. Protection class (DIN 40050) plugged and screwed: IP 67

Selection table M12 connectors with cable (5m cable length) KB 095-5000-5

KB 095-5000-5A without cable KD 095-5

KD 095-5A

Dimensioned drawings

Mounting systems BT 95

US 18

A

View turned by 45°

18 Series Accessories - 03

0202

– 157 –

Page 158

Leuze electronic

Leuze electronic GmbH + Co. http://www.leuze.de

Post-box 1111 D-73277 Owen-Teck Tel. ++49 7021 5730

– 158 –