Page 967

Leuze electronic

Optical Sensor ABCs

Cubic Series

Cylindrical Series – Mini photoelectric sensors – Fibre optic devices

Forked Photoelectric Sensors

Measuring Sensors

Contrast Scanners – Colour Sensors – Luminescence Scanners

Explosion Protection

Protective Photoelectric Sensors – Type 2

Accessories

Further Product Range

Appendix – Index

– 967 –

Page 968

Leuze electronic

– 968 –

Page 969

Leuze electronic

Further product range Please order documents separately

– 969 –

Page 970

Leuze electronic Double sheet testing units Double sheet testing units prevent the pulling-in of double paper/cardboard sheets or foils on printing/paper processing machines or in packaging applications. The optimal solution for every application can be found due to the different physical principles of operation. DB 07

Optical system for control with the transmitted light process and manual adjustment. Optical/capacitive system with automatic calibration for clockcontrolled machines. Ultrasonic system with varying functionality. Ultrasonic system for connection of two detection units. Ultrasonic/capacitive system with wide detection range and highest functionality.

DB 11 DB 12 DB 13 DB 14

Light attachment ILS 171 Throughbeam light attachment with dynamic switching behaviour for detection of small objects (e.g. ejection control). ILS 171

Operating range

Operating voltage Switching output

Connection

1.5m/4m

24VDC

Plug

PNP

NT power supply units The power supply units supply connected photoelectric sensors with 24VDC voltage. Relays are available for switching larger loads. Number of sensors

Operating voltage

Output

Connection

Sensor connection

Mounting type

NT 1/3

3

AC

Relay

Terminals

PNP/NPN

Screws

NT 7

1

AC

Relay

Terminals

PNP/NPN

Screws

NT 21

1

AC

Relay

Terminals

PNP/NPN

Screws, standard rail

NT 23/2

2

AC

Relay

Terminals

PNP/NPN

Screws, standard rail

NT 30

2

AC

Relay

Terminals

PNP/NPN

Screws

– 970 –

Page 971

Leuze electronic 80 Series Compact photoelectric sensor series in robust plastic housing AC/DC respectively UC supply voltages as well as PNP/NPN or relay outputs enable unproblematic application in almost any environment. 4 through-borings enable a large number of installation possibilities even in mechanically difficult environment. Type

Functions

Operating range/ Operating Scanning range voltage

Output Connection

RK 80/7

Retro-reflective photoelectric sensor 3m

20 … 250VUC Relay

RK 80/2

Retro-reflective photoelectric sensor 3m

11 … 30VDC

NPN

Cable Cable

RK 80/4

Retro-reflective photoelectric sensor 3m

11 … 30VDC

PNP

Cable

RK 80/2GD

Retro-reflective photoelectric sensor 2m

24V ±10%

NPN

Cable

RK 80/2-200 Energetic scanner

200mm

11 … 30VDC

NPN

Cable

RK 80/4-200 Energetic scanner

200mm

11 … 30VDC

PNP

Cable

230VAC

Relay

Cable

LS 80/7

Throughbeam photoelectric sensor 8m

Accessories: Alignment angle BT 80 for universal fastening and exact alignment of the sensors.

Optical tool breakage control Compact laser throughbeam photoelectric sensor for reliable detection of the smallest drillers, from e.g. >0.8mm. The conception of the sensor enables the static and dynamic control at a desired point up to 8m distance between transmitter and receiver. Visible light spot, receiver-side multi display (signal size) and integrated alignment / mounting system enable time saving, optimal adjustment of transmitter and receiver. Warning output for contamination message. Connection for pressurised air to keep the optical surfaces constantly clean, even under especially rough environmental conditions. Designation

Operating range

Operating voltage

Output

Connection

BKL 706

8m1)

10 … 30VDC

Static PNP Dynamic NPN2)

Cable PUR or PVC

1) 2)

Longer operating ranges possible without diaphragms Pulse length on request

Diffuse reflection light scanner with background suppression FRK 61, FRK 173 Robust construction with metal housing for most demanding requirements. Reliable detection of almost every object with background suppression. Two separately adjustable scanning ranges at the DFRK 61 allow for two separate switching points. Voltage free switching output (relay/change-over), slow operation/slow release at the FRK 173 for optimal adjustment to the application.

Designation

Scanning range

Operating voltage

Output

Connection

DFRK 61

1/2m Two independent scanning ranges

DC

PNP

Plug

FRK 61

2m

DC

PNP

Plug

FRK 173/R-2000 DL

2m

11 … 30VDC 11 … 24VAC

Relay

M12

– 971 –

Page 972

Leuze electronic

– 972 –