The text of a spec sheet · part 1 of 1
KRTW 3B White light contrast scanner, pages 1 to 8
Pages 1 to 8 of 8
The original document is the PDF (1.4 MB). This is its text as extracted, unedited; tables and drawings read best in the PDF, and each page heading opens it at that page.
For the Leuze KRTW-3B
Page 1
KRTW 3B
White light contrast scanner en 05-2011/04 50110626-02
Dimensioned drawing
10 kHz
14.5mm
10 - 30 V DC
We reserve the right to make changes • DS_KRTW3B_en.fm z White light transmitter z Various teach variants z Short response time z Switching threshold adjustment via EasyTune z Level adaptation for glossy objects z Keyboard lockout z Remote teach via cable z Pulse stretching 20ms A B C D E F G H J
C
Green indicator diode Yellow indicator diode Light spot orientation horizontal Light spot orientation vertical Transmitter Receiver Optical axis Teach button Attachment sleeve
Electrical connection
UL US LISTED
Plug connection, 4-pin IEC 60947...
IEC 60947...
IP 67
Accessories: (available separately)
z Mounting systems (BT 3…) z Cable with M8 or M12 connector (K-D …)
Phone: 800.894.0412 - Fax: 888.723.4773 - Web: www.ctiautomation.net - Email: info@ctiautomation.net
Page 2
KRTW 3B Specifications
Tables
Optical data
KRTW 3B/…10-S8
Scanning range 1) Light spot dimensions Light spot orientation Light source 2) Wavelength
14.5mm ± 2mm 1.5mm x 4mm (at a distance of 14.5mm) vertical or horizontal (see dimensioned drawing) white LED (optimized through YellowBoost) 430 … 700nm
KRTW 3B/…21-S8
Sensor operating modes IO-Link SIO Dual Core
COM2 (38.4kBaud) standard push-pull no
Timing of the sensor Internal switching frequency Internal response time Response jitter, internal Repeatability 3) Delay before start-up Conveyor speed during teach Teach process Teach delay
6kHz 10kHz 83μs 50μs 20μs 20μs 0.02mm 0.02mm ≤ 300ms ≤ 0.1m/s for a mark width of 1mm static 1-point, static 2-point or dynamic 2-point ≤ 10ms
Diagrams
Timing of the outputs Response time
Pin 4
IO-Link COM2: SIO:
acc. to IO-Link specification (typically 2.5ms) 50μs
Electrical data Operating voltage UB 4) Residual ripple Output/function with SIO with COM2 …/2… …/4… …/6… …/6…
Signal voltage high/low Output current Open-circuit current
10 … 30VDC (incl. residual ripple) 18 … 30VDC (incl. residual ripple) ≤ 15% of UB pin 4: GND if mark detected pin 4: UB if mark detected pin 4: IO-Link SIO mode, UB if mark detected pin 4: IO-Link COM2 mode, see configuration file IODD ≥ (UB -2V)/≤ 2V max. 100mA ≤ 20mA
Indicators Green LED in continuous light Green and yellow LED flashing at 3Hz Green and yellow LED flashing at 8Hz Green LED off and yellow LED flashing at 8Hz Yellow LED in continuous light Transmitter LED, white flashing at 8Hz ready teach event active teaching error sensor error mark detected (dependent on the teach sequence) teaching error
Mechanical data Housing 5)
plastic (PC-ABS), with/without attachment sleeve, nickel-plated steel plastic (PMMA) with M8 metal plug: 10g with M8 plastic plug: 8g M8 connector, metal or plastic
Optics cover Weight Connection type
Environmental data Ambient temp. (operation/storage) Protective circuit 6) VDE safety class Protection class Light source Standards applied Certifications
-30°C … +55°C/-30°C … +70°C 2, 3 III IP 67 free group (in accordance with EN 62471) IEC 60947-5-2 UL 508 4)
Remarks z Approved purpose: This product may only be used by qualified personnel and must only be used for the approved purpose. This sensor is not a safety sensor and is not to be used for the protection of persons. z With glossy objects, the sensor is to be fastened at an inclination of approx. 10° relative to the object surface. 10 °
Options Input pin 2 Function characteristics Input active/not active Output pin 4 Line teach active Error after line teach keyboard lockout / line teach / pulse stretching ≥ 8V/≤ 2V or not connected for SIO for COM2 for SIO for COM2
2Hz at the switching output see configuration file IODD 2Hz at the switching output see configuration file IODD
1) Scanning range: recommended range with performance reserve 2) Average life expectancy 100,000h at an ambient temperature of 25°C 3) At conveyor speed 1m/s 4) For UL applications: for use in class 2 circuits according to NEC only 5) Patent Pending Publ. No. US 7,476,848 B2 6) 2=polarity reversal protection, 3=short-circuit protection for all transistor outputs
Phone: 800.894.0412 - Fax: 888.723.4773 - Web: www.ctiautomation.net - Email: info@ctiautomation.net
Page 3
KRTW 3B
White light contrast scanner
Selection table
Order code Î
Equipment Ð Transmitter color white light RGB (red, green, blue) laser-generated red light Light spot orientation vertical horizontal round Output (OUT 1) PNP transistor output NPN transistor output push-pull switching output IO-Link COM2 Input (IN) teach input Housing standard economy Connection M8 connector, metal 4-pin M8 connector, plastic 4-pin 200mm cable with M12 connector 4-pin Teach-in method static 1-point static 2-point dynamic 2-point Response time / 50μs / 10kHz Switching frequency 83μs / 6kHz 125μs / 4kHz Configuration switching threshold adjustment with EasyTune via teach button remote teach, keyboard lockout and pulse stretching via pin 2 teach level 1, teach-level 2 and pulse stretching via teach button teach level 1, teach-level 2 via teach button
KRTW 3B/4.1110-S8 Part no. 50110572 KRTW 3B/4.1121-S8 Part no. 50110576 KRTW 3B/4.1321-S8 Part no. 50110580 KRTW 3B/6.1121-S8 Part no. 50111319 KRTW 3B/2.1110-S8 Part no. 50110573 KRTW 3B/4.1110,200-S12 Part no. 50110574 KRTW 3B/2.1110,200-S12 Part no. 50110575 KRTW 3B/2.1121-S8 Part no. 50110577 KRTW 3B/4.1121,200-S12 Part no. 50110578 KRTW 3B/2.1121,200-S12 Part no. 50110579 KRTW 3B/2.1321-S8 Part no. 50110581 KRTW 3B/4.1321,200-S12 Part no. 50110582 KRTW 3B/2.1321,200-S12 Part no. 50110583
Order guide z z z z z z z z z z z z z z z z z z z z z z z z z z z z z z z z z z z z z z z z z z z z z z z z z z z z z z z z z z z z z z z z z z z z z z z z z z z z z z z z z z z z z z z z z z z z z z z z z z z z z z z z z z z z z z z z z z z z z z z z z z z z z z z z z z z z
Phone: 800.894.0412 - Fax: 888.723.4773 - Web: www.ctiautomation.net - Email: info@ctiautomation.net
Page 4
KRTW 3B IO-Link process data The sensor transmits 2 bytes to the master. Data bit 15 14 13 12 11 10
9
8
7
6
5
4
3
2
1
0
Assignment
Default settings
Switching output
0 = no mark, 1 = mark detected
Not used
Free
Sensor operation
0 = off, 1 = on
Switching threshold LSB Value range 0 … 31 (0 … 100% in approx. 3% steps)
Switching threshold Switching threshold
0% = min. switching threshold 100% = max. switching threshold
Switching threshold Switching threshold MSB Active transmitter LSB
00 = red, 01 = green or white,
Active transmitter MSB
10 = blue, 11 = all colors on (teach-in active)
Not used
Free
Measurement value LSB Value range 0 … 31 (0 … 100% in approx. 3% steps)
Measurement value Measurement value
0% = min. signal level 100% = max. signal level
Measurement value Measurement value MSB
Additional information on the IO-Link service data is available on request.
Static 2-point teach Suitable for manual positioning of the marks (availability dependent on sensor type). Switching threshold in center: Position the background. Press teach button for 2 … 7s and release.
LEDs flash simultaneously.
Position the mark.
Briefly press teach button. Sensor in RUN mode. Yellow LED illuminates.
2 … 7s Value for background is accepted.
Simultaneous flashing
Value for mark is accepted.
Switching threshold set in the center.
Switching threshold near the mark: Position the background. Press teach button for 7 … 12s and release.
7 … 12s Value for background is accepted.
LEDs flash alternatingly.
Alternating flashing
Position the mark.
Briefly press teach button. Sensor in RUN mode. Yellow LED illuminates.
Value for mark is accepted.
Switching threshold is set near the mark.
Phone: 800.894.0412 - Fax: 888.723.4773 - Web: www.ctiautomation.net - Email: info@ctiautomation.net
Page 5
KRTW 3B
White light contrast scanner
Dynamic 2-point teach Suitable for marks moved during automated machine processes (availability dependent on sensor type). Switching threshold in center Position the background. Press teach button for 2 … 7s and release.
LEDs flash simultaneously.
Allow marks to pass through dynamically.
Briefly press teach button. Sensor in RUN mode. Yellow LED is off.
2 … 7s Measurement window opens.
Simultaneous flashing
Measurement window closes.
Switching threshold set in the center.
Switching threshold near the mark Position the background. Press teach button for 7 … 12s and release.
LEDs flash alternatingly.
Allow marks to pass through dynamically.
Briefly press teach button. Sensor in RUN mode. Yellow LED is off.
7 … 12s Measurement window opens.
Alternating flashing
Measurement window closes.
Switching threshold is set near the mark.
Static 1-point teach Suitable for detecting all marks outside of the reference value (availability dependent on sensor type). Standard sensitivity Position the reference value.
Press teach button for 2 … 7s.
LEDs flash simultaneously.
Release teach button.
Sensor in RUN mode. Yellow LED is off.
Value is accepted.
Standard sensitivity is set.
Release teach button.
Sensor in RUN mode. Yellow LED is off.
Value is accepted.
High sensitivity is set.
2 … 7s Simultaneous flashing
High sensitivity Position the reference value.
Press teach button for 7 … 12s.
LEDs flash alternatingly.
7 … 12s Alternating flashing
Phone: 800.894.0412 - Fax: 888.723.4773 - Web: www.ctiautomation.net - Email: info@ctiautomation.net
Page 6
KRTW 3B Switching threshold diagrams Static 2-point teach
Label with marks
1. Teach point on background
2. Teach point on mark
Receive signal Switching threshold in center Switching threshold near the mark Switching output for switching threshold in center Switching output for switching threshold near the mark
Dynamic 2-point teach
Label with marks
Open measurement window
Close measurement window
Receive signal Switching threshold in center Switching threshold near the mark Switching output for switching threshold in center Switching output for switching threshold near the mark
Static 1-point teach
Label with marks
Teach reference value Standard sensitivity
Receive signal High sensitivity
Switching output for standard sensitivity
Switching output for high sensitivity
Phone: 800.894.0412 - Fax: 888.723.4773 - Web: www.ctiautomation.net - Email: info@ctiautomation.net
Page 7
KRTW 3B
White light contrast scanner
Pulse stretching option Switching pulse stretching on or off: Press the teach button longer than 12s.
Only the green LED flashes.
Release teach button.
Change is displayed and accepted automatically after 2s. Sensor in RUN mode.
After 2s the yellow LED is back to normal operation, displaying the state of the switching output.
after 2s > 12s
After releasing the teach button, the yellow LED displays the new pulse stretching status for 2s: yellow LED on: pulse stretching ON yellow LED off: pulse stretching OFF
"EasyTune" option - fine tuning of the switching threshold Following power-on and completed teach event:
Green LED illuminates continuously (ready), Yellow LED on/off continuously (mark detected/not detected).
Increasing the switching threshold: Long press of the button = large force expenditure = increase switching threshold
2-point teach Label with marks
Each press of the button with a duration between 200ms and 2s increments the switching threshold.
1. Teach point on background Receive signal
Increase the switching threshold
Switching threshold
Green LED flashes briefly once
2. Teach point on mark
1-point teach Label with marks
200ms … 2s Teach reference value A press of the button is acknowledged by a single, brief flash of the green LED – the new switching threshold is now valid.
Increase the switching threshold
Receive signal Switching threshold
Reducing the switching threshold: Short press of the button = small force expenditure = reduce switching threshold
2-point teach Label with marks
Each press of the button with a duration between 2ms and 200ms decrements the switching threshold.
1. Teach point on background
2. Teach point on mark
Receive signal Switching threshold Green LED flashes briefly once 2ms … 200ms
Reduce the switching threshold 1-point teach
Label with marks Teach reference value
A press of the button is acknowledged by a single, brief flash of the green LED – the new switching threshold is now valid.
Receive signal Switching threshold
Reduce the sitching threshold
If the upper or lower end of the adjustment range is reached, the green and yellow LEDs flash at a considerably higher frequency of 8Hz for the duration of one second.
Phone: 800.894.0412 - Fax: 888.723.4773 - Web: www.ctiautomation.net - Email: info@ctiautomation.net
Page 8
KRTW 3B Sensor adjustments via the input IN (Pin 2) The following description applies to PNP switching logic! Signal level LOW ≤ 2V Signal level HIGH ≥ (UB-2V) With the NPN models, the signal levels are inverted!
Switching threshold in center / standard sensitivity Accept 1st teach value (background, reference value / open measurement window)
Accept 2nd teach value (mark / close measurement window)
HIGH t = 20 ... 80 ms
LOW t
Switching threshold near the mark / high sensitivity Accept 1st teach value (background, reference value / open measurement window)
Accept 2nd teach value (mark / close measurement window)
HIGH t = 120 ... 180 ms
LOW t
Pulse stretching ON
HIGH t = 220 ... 280 ms
LOW t
Pulse stretching OFF
HIGH t = 320 ... 380 ms
LOW t
Locking the teach button via the input IN (Pin 2) A static HIGH signal (≥ 20ms) at the teach input locks the teach button on the sensor if required, such that no manual operation is possible (e.g., protection from erroneous operation or manipulation). If the teach input is not connected or if there is a static low signal, the button is unlocked and can be operated freely.
Phone: 800.894.0412 - Fax: 888.723.4773 - Web: www.ctiautomation.net - Email: info@ctiautomation.net