Spec sheet · Leuze
Leuze FRK 92 Spec Sheet
Spec sheet2 pagesPDF 68 KB
Both pages are below, each with its text.
Covers · 1 model
The models it covers
From the sheet · read page by page
Key facts from this sheet
Each line names its page in the PDF.
A two-page Leuze electronic data sheet for the FRK 92 diffuse reflection light scanner with background suppression, ordered as the FRK 92/4-300 L and FRK 92/4-300 S. It gives the features, optical, electrical, mechanical and environmental data, response diagrams, accessories and an order guide.
- Device
- Diffuse reflection light scanner with background suppression p. 1
- Supply voltage
- 10 … 30VDC (incl. residual ripple) p. 2
- Output
- PNP transistor output; light or dark switching, chosen by reversing the polarity of UB p. 2
- Connection
- M12 connector or 6-pin standard plug p. 1
- Light source
- LED (modulated light) p. 2
- Adjustment
- Exact adjustment with a multiturn potentiometer p. 1
- Housing
- Diecast zinc housing with glass optics p. 1
- Enclosure
- IP 67; IP 65 for FRK 92/4-300 S p. 2
- Indicator
- Yellow LED for reflection p. 2
- Versions
- FRK 92/4-300 L (L types: M12 connector) and FRK 92/4-300 S p. 2
- Accessories
- Mounting systems (BT 92, UMS 1), M12 connectors (KD …), ready-made cables (KB …), sold separately p. 1
Good to know
- The upper and lower scanning range limits can change with poorly reflecting materials. p. 2
- The scanner is also available with an integrated AS-i chip for direct connection to an AS-i system. p. 2
Questions this sheet answers
What supply voltage does the Leuze FRK 92 need?
10 to 30 VDC, including residual ripple. p. 2
Is the FRK 92 output PNP or NPN?
A PNP transistor output; light or dark switching is chosen by reversing the polarity of the supply voltage UB. p. 2
What connector does the FRK 92 use?
An M12 connector or a 6-pin standard plug; the L types have the M12 connector. p. 1, 2
What mounting accessories fit the FRK 92?
The mounting systems BT 92 and UMS 1, sold separately. p. 1
The file
Size and text
Every page · 2
Read it here
Each page as it is printed, and its words beside it, so a phone can search and copy them.
Page1of 2
Open in the PDF
The text of page 1, from the PDF itself
Leuze electronic FRK 92
Diffuse reflection light scanner with background suppression Dimensioned drawing
5 … 440mm 10 - 30 V DC
! Very good black/white performance, exact adjustment via multiturn potentiometer ! Compact construction with robust diecast zinc housing and glass optics for protection against environmental influences ! Electrical connection with M12 connector or 6-pin standard plug
A Scanning range adjustment B Indicator diode C Optical axis Preferred entry direction for objects " + # + $
We reserve the right to make changes • 92_d01e.fm
Electrical connectionIEC 60947...IEC 60947...IP 67
Accessories: (available separately)
! Mounting systems (BT 92, UMS 1) ! M12 connectors (KD …) ! Ready-made cables (KB …)
Leuze electronic GmbH + Co KG www.leuze.de
Post-box 1111 D-73277 Owen-Teck Tel. ++49 7021 5730
FRK 92… - 04
Page2of 2
Open in the PDF
The text of page 2, from the PDF itself
Leuze electronic FRK 92 Specifications
Tables 1 5 2 15 3 20
Optical data
Typ. scanning range limit (white 90%) 1) Scanning range 2) Adjustment range Light beam characteristic Light source Wavelength
5 … 440mm see table 50 … 300mm divergent LED (modulated light) 880nm
440
1 white 90% 2 grey 18% 3 black 6%
Timing Switching frequency Response time Delay before start-up
300 390 360
280 260
Scanning range [mm] Typ. scanning range limit [mm]
500Hz 1ms ≤ 100ms
Electrical data 10 … 30VDC (incl. residual ripple) ≤ 15% of UB ≤ 30mA PNP transistor output light or dark switching (by reversing the polarity of UB) ≥ (UB -2V)/≤ 2V max. 100mA
Indicators LED yellow
reflection
Mechanical data Housing Optics Weight Connection type
diecast zinc glass 140g M12 connector or 6-pin standard plug
Diagrams Typ. response behaviour (white 90%) Misalignment y [mm]
Operating voltage UB Residual ripple Bias current Switching output Function characteristics Signal voltage high/low Output current
15 10 5 0 -5 -10 -15y2y1 050100Environmental data200250300y2
-20°C … +60°C/-30°C …+70°C I for S types II for L types (M12 connector) 2, 3 IP 67, IP 65 for FRK 92/4-300 S 1 (acc. to EN 60825-1) IEC 60947-5-2
1) Typ. scanning range limit: max. attainable range without performance reserve 2) Scanning range: recommended range with performance reserve 3) Rating voltage 250VAC 4) 2=polarity reversal protection, 3=short-circuit protection for all outputs
y1 x
Typ. black/white behaviour Red. of scan range y [mm]
Ambient temp. (operation/storage) VDE safety class VDE safety class 3) Protective circuit 4) Protection class LED class Standards applied
150
Distance x [mm]
90 80 70 60 50 40 30 20 10 0
A B C
0
50 100 150 200 250 300 350 400 450
Scanning range x [mm] A white 90% B grey 18% C black 6% y
x
Order guide with M12 connector with 6-pin standard plug
FRK 92… - 04Remarks DesignationPart No.
FRK 92/4-300 L FRK 92/4-300 S
500 19283 500 11213
! The upper and lower scanning range limits can change with poorly reflecting materials. ! The diffuse reflection light scanner is also available with integrated AS-i chip for direct connection to the AS-i system.