Browse
(440) 299-7778
Menu
(440) 299-7778
One-year parts and labor warranty30-day money-back guaranteeEnglishEspañolContact
Page 1 of Leuze FRK 92 Spec Sheet

Spec sheet · Leuze

Leuze FRK 92 Spec Sheet

Spec sheet2 pagesPDF 68 KB

Both pages are below, each with its text.

Download the PDF68 KB

Covers · 1 model

The models it covers

From the sheet · read page by page

Key facts from this sheet

Each line names its page in the PDF.

A two-page Leuze electronic data sheet for the FRK 92 diffuse reflection light scanner with background suppression, ordered as the FRK 92/4-300 L and FRK 92/4-300 S. It gives the features, optical, electrical, mechanical and environmental data, response diagrams, accessories and an order guide.

Device
Diffuse reflection light scanner with background suppression p. 1
Supply voltage
10 … 30VDC (incl. residual ripple) p. 2
Output
PNP transistor output; light or dark switching, chosen by reversing the polarity of UB p. 2
Connection
M12 connector or 6-pin standard plug p. 1
Light source
LED (modulated light) p. 2
Adjustment
Exact adjustment with a multiturn potentiometer p. 1
Housing
Diecast zinc housing with glass optics p. 1
Enclosure
IP 67; IP 65 for FRK 92/4-300 S p. 2
Indicator
Yellow LED for reflection p. 2
Versions
FRK 92/4-300 L (L types: M12 connector) and FRK 92/4-300 S p. 2
Accessories
Mounting systems (BT 92, UMS 1), M12 connectors (KD …), ready-made cables (KB …), sold separately p. 1

Good to know

  • The upper and lower scanning range limits can change with poorly reflecting materials. p. 2
  • The scanner is also available with an integrated AS-i chip for direct connection to an AS-i system. p. 2

Questions this sheet answers

What supply voltage does the Leuze FRK 92 need?

10 to 30 VDC, including residual ripple. p. 2

Is the FRK 92 output PNP or NPN?

A PNP transistor output; light or dark switching is chosen by reversing the polarity of the supply voltage UB. p. 2

What connector does the FRK 92 use?

An M12 connector or a 6-pin standard plug; the L types have the M12 connector. p. 1, 2

What mounting accessories fit the FRK 92?

The mounting systems BT 92 and UMS 1, sold separately. p. 1

The file

Size and text

Pages2
PDF68 KB
TextText from the PDF itself.

Every page · 2

Read it here

Each page as it is printed, and its words beside it, so a phone can search and copy them.

Page 1 of Leuze FRK 92 Spec Sheet

The text of page 1, from the PDF itself

Leuze electronic FRK 92

Diffuse reflection light scanner with background suppression Dimensioned drawing

5 … 440mm 10 - 30 V DC

! Very good black/white performance, exact adjustment via multiturn potentiometer ! Compact construction with robust diecast zinc housing and glass optics for protection against environmental influences ! Electrical connection with M12 connector or 6-pin standard plug

A Scanning range adjustment B Indicator diode C Optical axis Preferred entry direction for objects " + # + $

We reserve the right to make changes • 92_d01e.fm

Electrical connectionIEC 60947...IEC 60947...IP 67

Accessories: (available separately)

! Mounting systems (BT 92, UMS 1) ! M12 connectors (KD …) ! Ready-made cables (KB …)

Leuze electronic GmbH + Co KG www.leuze.de

Post-box 1111 D-73277 Owen-Teck Tel. ++49 7021 5730

FRK 92… - 04

Page 2 of Leuze FRK 92 Spec Sheet

The text of page 2, from the PDF itself

Leuze electronic FRK 92 Specifications

Tables 1 5 2 15 3 20

Optical data

Typ. scanning range limit (white 90%) 1) Scanning range 2) Adjustment range Light beam characteristic Light source Wavelength

5 … 440mm see table 50 … 300mm divergent LED (modulated light) 880nm

440

1 white 90% 2 grey 18% 3 black 6%

Timing Switching frequency Response time Delay before start-up

300 390 360

280 260

Scanning range [mm] Typ. scanning range limit [mm]

500Hz 1ms ≤ 100ms

Electrical data 10 … 30VDC (incl. residual ripple) ≤ 15% of UB ≤ 30mA PNP transistor output light or dark switching (by reversing the polarity of UB) ≥ (UB -2V)/≤ 2V max. 100mA

Indicators LED yellow

reflection

Mechanical data Housing Optics Weight Connection type

diecast zinc glass 140g M12 connector or 6-pin standard plug

Diagrams Typ. response behaviour (white 90%) Misalignment y [mm]

Operating voltage UB Residual ripple Bias current Switching output Function characteristics Signal voltage high/low Output current

15 10 5 0 -5 -10 -15y2y1 050100Environmental data200250300y2

-20°C … +60°C/-30°C …+70°C I for S types II for L types (M12 connector) 2, 3 IP 67, IP 65 for FRK 92/4-300 S 1 (acc. to EN 60825-1) IEC 60947-5-2

1) Typ. scanning range limit: max. attainable range without performance reserve 2) Scanning range: recommended range with performance reserve 3) Rating voltage 250VAC 4) 2=polarity reversal protection, 3=short-circuit protection for all outputs

y1 x

Typ. black/white behaviour Red. of scan range y [mm]

Ambient temp. (operation/storage) VDE safety class VDE safety class 3) Protective circuit 4) Protection class LED class Standards applied

150

Distance x [mm]

90 80 70 60 50 40 30 20 10 0

A B C

0

50 100 150 200 250 300 350 400 450

Scanning range x [mm] A white 90% B grey 18% C black 6% y

x

Order guide with M12 connector with 6-pin standard plug

FRK 92… - 04Remarks DesignationPart No.

FRK 92/4-300 L FRK 92/4-300 S

500 19283 500 11213

! The upper and lower scanning range limits can change with poorly reflecting materials. ! The diffuse reflection light scanner is also available with integrated AS-i chip for direct connection to the AS-i system.

0501

More documents · 1

For the same models