Page 59
Configure
3.6.9 Flush Mode (Buffer Flushing) Using this parameter, you can control line handling and network buffers with connection startup and disconnect. You can also select between two different packing algorithms. Note: See Table 35 - Binary to Hexadecimal Conversion Table. Table 13 - Flush Mode Options Function Input Buffer (Serial to Network) Clear with a connection that is initiated from the UDS to the network Clear with a connection initiated from the network to the UDS Clear when the network connection to or from the UDS is disconnected Output Buffer (Network to Serial) Clear with a connection that is initiated from the UDS to the network Clear with a connection initiated from the network to the UDS Clear when the network connection to or from the UDS is disconnected Alternate Packing Algorithm (Pack Control) Enable
CoBox-FL User Guide
7
6
5
4
3
2
1
0
1 1 1
1 1 1 1
3-21
Page 60
Configure
3.6.10 Pack Control Two firmware-selectable packing algorithms define how and when packets are sent to the network. The standard algorithm is optimized for applications in which the unit is used in a local environment, allowing for very small delays for single characters while keeping the packet count low. The alternate packing algorithm minimizes the packet count on the network and is especially useful in applications in a routed Wide Area Network (WAN). Adjusting parameters in this mode can economize the network data stream. Pack control settings are enabled in Flush Mode. Set this value to 00 if specific functions are not needed. Note: See Table 35 - Binary to Hexadecimal Conversion Table. Table 14 - Pack Control Options Option Idle Time Force transmit: 12ms Force transmit: 52ms Force transmit: 250ms Force transmit: 5sec Trailing Characters None One Two Send Characters 2-Byte Send Character Sequence Send Immediately After Send chars
7
6
5
4
3
0 0 1
2
1
0
0 0 1 1
0 1 0 1
0 1 0
1 1
Idle Time: Idle time to "Force transmit" defines how long the unit should wait before sending accumulated characters. This wait period is between characters. If there is an idle period between characters equal to the force transmit set, then the unit will package up the serial data currently in the buffer and send it to the network. Trailing Characters: In some applications, CRC, Checksum, or other trailing characters follow the end-of-sequence character; this option helps to adapt frame transmission to the frame boundary.
3-22
CoBox-FL User Guide
Page 61
Configure
Send Characters: If 2-Byte Send Character Sequence is enabled, the unit interprets the sendchars as a 2-byte sequence; if not set, they are interpreted independently. If Send Immediately After Characters is not set, any characters already in the serial buffer are included in the transmission after a "transmit" condition is found. If set, the unit sends immediately after recognizing the transmit condition (sendchar or timeout). Note: A transmission might occur if status information needs to be exchanged or an acknowledgment needs to be sent.
3.6.11 DisConnTime (Inactivity Timeout) Use this parameter to set an inactivity timeout. The connection is dropped if there is no activity on the serial line before the set time expires. Enter time in the following format: mm:ss, where m is the number of minutes and s is the number of seconds. To disable the inactivity timeout, enter 00:00.
3.6.12 Send Characters You can enter up to two characters in hexadecimal representation in the parameters "sendchar." If a character received on the serial line matches one of these characters, it is sent immediately, along with any awaiting characters, to the TCP connection. This minimizes the response time for specific protocol characters on the serial line (for example, ETX, EOT, etc.). Setting the first sendchar to 00 disables the recognition of the characters. Alternatively, the two characters can be interpreted as a sequence (see Pack Control on page 3-22).
3.6.13 Telnet Terminal Type This parameter appears only if the terminal type option is enabled in Disconnect Mode (see DisConnMode on page 3-20 above). If this option is enabled, you can use the terminal name for the Telnet terminal type. Enter only one name. If the terminal type option is enabled, the unit also reacts to the EOR (end of record) and binary options, which can be used for applications like terminal emulation to IBM hosts.
3.6.14 Channel (Port) Password This parameter appears only if the channel (port) password option is enabled in Disconnect Mode (see DisConnMode on page 3-20). If set, you can set a password on the serial port.
CoBox-FL User Guide
3-23
Page 62
Configure
3.7 Expert Settings Note: You can change these settings via Telnet or serial connections only, not on the WebManager. Note: The Expert Settings option does not appear with CoBox-FL-IAP. These parameters should only be changed if you are an expert and definitely know the consequences the changes might have. TCP Keepalive time in s (1s – 65s; 0s=disable): (0)
3.7.1 TCP Keepalive time in s This option allows you to change how many seconds the unit will wait during a silent connection before attempting to see if the currently connected network device is still on the network. If the unit then gets no response, it will drop that connection.
3.8 Security Settings Note: You can change these settings via Telnet or serial connections only, not on the WebManager. We recommend that you set security over the dedicated network or over the serial setup. If you set parameters over the network (Telnet 9999), someone else could capture these settings. Disable SNMP (N) SNMP Community Name (public): Disable Telnet Setup (N) Disable TFTP Firmware Update (N) Disable Port 77FEh (N) Disable Web Server (N) Enable Enhanced Password (N)
(Not with IAP) (Not with IAP)
3.8.1 Disable SNMP Note: This option does not appear with CoBox-FL-IAP. This setting allows you to disable the SNMP protocol on the unit for security reasons.
3.8.2 SNMP Community Name Note: This option does not appear with CoBox-FL-IAP. This option allows you to change the SNMP Community Name on the unit. This allows for ease of management, and possibly some security. If someone tries to violate security but doesn’t know what community to connect to, that person will be unable to get the SNMP community information from the unit.
3-24
CoBox-FL User Guide
Page 63
Configure
3.8.3 Disable Telnet Setup This setting defaults to the N (No) option. The Y (Yes) option disables access to this Configuration Menu by Telnet (port 9999). It only allows access via the Web pages and the serial port of the unit.
3.8.4 Disable TFTP Firmware Upgrade This setting defaults to the N (No) option. The Y (Yes) option disables the use of TFTP to perform network firmware upgrades. With this option, firmware upgrades can be performed only by using a *.hex file over the serial port of the unit.
3.8.5 Disable Port 77FE (Hex) Port 77FE is a setting that allows DeviceInstaller, Web Pages, and custom programs to configure the unit remotely. You may wish to disable this capability for security purposes. For more information about remote configuration, see the Lantronix Embedded Integration Kit user guide on the Lantronix Web site www.lantronix.com. The default setting is the N (No) option, which enables remote configuration. You can configure the unit by using DeviceInstaller, Web pages, Telnet, or serial configuration. The Y (Yes) option disables remote configuration and Web pages. Note: The Yes option disables many of the GUI tools for configuring the Device Server, including the embedded Web Page Configuration tool.
3.8.6 Disable Web Server This setting defaults to the N (option). The Y (Yes) option disables the use of the Web Page Configuration tool that is built into the unit.
3.8.7 Enable Enhanced Password This setting defaults to the N (option), which allows you to set a 4-character password that protects the Configuration Menu via Telnet and Web pages. The Y (Yes) option allows you to set an extended security password of 16-characters for protecting Telnet access.
3.9 Factory Defaults Select 7 to reset the unit’s Channel 1 and Enhanced Security to the factory default settings. The server configurations (IP address information) remain unchanged.
CoBox-FL User Guide
3-25
Page 64
Configure
3.10 Exit Configuration Mode Select 8 to exit the configuration mode without saving any changes or rebooting. Select 9 to save all changes and reboot the device. All values are stored in nonvolatile memory.
3.11 Get Configuration The device configuration information is stored in flash memory and can be read and saved in a configuration file (filename.cfg). To get the configuration information, click the Get Configuration icon button on the Device Management window. The following dialog appears.
The Device IP Address is shown in the first field. This is the device selected in the DeviceInstaller main window. In the Configuration File field, click the Open File button to select a filename for the configuration file. Click the Get button and the file information is read from the device and saved in the selected file.
3-26
CoBox-FL User Guide
Page 65
Configure
3.12 Set Configuration Device configuration information can be saved in a file and later used to set the configuration of one or several devices. To set the configuration of a device from a saved file, click the Set Configuration button on the Device Management window. The following dialog appears.
The Device IP Address is shown in the first field. This is the device selected in the DeviceInstaller main window. In the Configuration File field, click the Open File button to select a configuration file. Click the Set button and the file information is read and stored in the device.
CoBox-FL User Guide
3-27