Page 39

Configure

3. Configuring the Unit You must configure the unit so that it can communicate on a network with your serial device. For example, you must set the way the unit will respond to serial and network traffic, how it will handle serial packets, and when to start or close a connection. You can configure your unit locally or remotely using the following procedures: • Use a standard Web browser to access the unit’s internal Web pages and configure the unit over the network. This is the easiest and preferred method. • Use a Telnet connection to configure the unit over the network. • Use a terminal or terminal emulation program to access the serial port locally. The unit’s configuration is stored in nonvolatile memory (NVRam) and is retained without power. You can change the configuration at any time. The unit performs a reset after the configuration has been changed and stored. Note: The configuration menus in this section show a typical device and all of the possible configuration options. Your device may have different configuration options.

3.1 Configuring via Web Browser Open your JAVA enabled web browser and enter the IP address. The Lantronix Web Manager page will display. Go to Web Manager Page for a summary of the menu selections. Note: The CoBox-FL-IAP may not have a web page or may use a different format web page.

CoBox-FL User Guide

3-1

Page 40

Configure

3.2 Using DeviceInstaller DeviceInstaller is a powerful software utility for configuring device servers from a network connection. This section uses the utility to demonstrate the various methods of configuring a device. The Device Management window is a common page for gaining access to different menus. . The Search 1. Start DeviceInstaller. Click the Search for network for devices icon Network window displays. 2. Click the Start Search button. A list of all active units displays. 3. Click the Save button. Click OK for the confirmation message. Click the Back button. 4. Click the Manage device configuration icon window.

to open the Device Management

5. For Web configuration, click the Web Configuration icon to start your browser. (A small Web Configuration window appears, showing the IP address.) Go to Web Manager Page on page 3-4 for a summary of the menu selections. Note: If your unit already has an IP address (see Methods of Assigning the IP Address), you can log into it using a standard Web browser that is Java enabled. Type the unit's IP address into the Web browser's URL (Address/Location) field.

3-2

CoBox-FL User Guide

Page 41

Configure

6. For Telnet configuration, click the Telnet to Device icon. A small Telnet to Device window appears, showing the IP Address and the Port address. The main Lantronix Universal Device Server window opens. Go to Using a Telnet Connection on page 3-10 for a summary of the menu selections. 7. To Get device configuration information see Get Configuration on page 3-26. Configuration information can be read from a device and saved in a file. 8. To Set the configuration of a specific device see Set Configuration on page 3-27 A device can be configured by reading a configuration file and sending the information to the device.

CoBox-FL User Guide

3-3

Page 42

Configure

3.3 Web Manager Page Note: The CoBox-FL-IAP may not have a web page or may use a different format web page. You can start a web browser for configuration by opening your JAVA enabled web browser and entering the IP address or by clicking the Web Configuration button on the Device Management window. The Lantronix Web Manager page will display.

Figure 11 - Lantronix Web-Manager Web Manager 3.0 has the following buttons: • • • • • • • • • •

Unit Configuration Server Properties Port Properties Factory Settings1 (also Factory Settings2 for devices with two serial channels) Update Settings Channel 1 (also Channel 2 for devices with two serial channels) Tech Support FTP – Site Back to Web-Manager Contact Us

1. Use the menu (pushbuttons) to navigate to sub pages where you can configure server settings. See explanations of the configuration parameters later in this chapter. 2. When you are finished, click the Update Settings button to save your settings.

3-4

CoBox-FL User Guide

Page 43

Configure

3.3.1 Unit Configuration Click the Unit Configuration button to display the following dialog box. This page contains the Server Configuration and the Port Configuration settings. These are static settings read from the device. Note: The following screen shots represent the web page shown when the device is loaded with cbxw300.cob firmware.

CoBox-FL User Guide

3-5

Page 44

Configure

3.3.2 Server Properties You can change the server properties by editing any of the fields. Lingering over one of the fields will display operator messages. Changing the IP address will require you to enter the new IP address in the browser to reload the page.

Figure 12 - Server Properties Configuration on the Web Browser Telnet Password In the Telnet Password field, enter a password to prevent unauthorized access to the Setup Mode via a Telnet connection to port 9999. The password is limited to 4 characters. (An enhanced password setting of 16 characters is available under Security Settings on the Telnet Setup Mode window.) Note: No password is required to access the Setup Mode window via a serial connection.

3-6

CoBox-FL User Guide

Page 45

Configure

3.3.3 Port Properties

Serial Protocol: RS232, RS422/485 4-wire, RS485 2-wire Speed: 1200, 2400, 4800, 9600, 19200, 38400, 57600, 115200 Character Size: 8, 7 Parity: None, Even, Odd Stop Bit: 1,2 Flow Control: None, XON/XOFF, XON/XOFF Pass Characters to Host, CTS/RTS (Hardware)

UDP Datagram Mode: Enable, Disable UDP Datagram Type: (User selectable) Incoming Connection: Accept unconditional, Accept Incoming/DTR (Inactive), Never accept incoming Response: Nothing (quiet), Character response Startup: No active startup, with any character, with active DTR (Inactive), with CR (0x0D) only, Manual Connection, Autostart, Modem Mode

Remote IP Address: (user selectable) Remote Port: (user selectable) Local Port: 10001 (default 10001, user selectable) CoBox-FL User Guide

3-7

Page 46

Configure

On Active Connection: Enable, Disable On Passive Connection: Enable, Disable At Time of Disconnect: Enable, Disable

Packing Algorithm: Enable, Disable Idle Time: Force transmit 12 ms, Force transmit 52 ms, Force Transmit 250 ms, Force Transmit 5000 ms Trailing Characters: None, One, Two Send Immediate After Sendchars: Enable, Disable Send Define2-Byte Sequence: Enable, Disable Send Character 01: (User Selectable) Send Character 02: (User Selectable)

3-8

CoBox-FL User Guide

Page 47

Configure

Disconnect Mode: with DTR Drop, Ignore DTR Check for CTRL-D to Disconnect: Enable, Disable Port Password: Enable, Disable Telnet Mode: Enable, Disable Inactivity Timeout: Enable, Disable Inactivity Timer: (User Selectable) Port Password: (User Selectable. Port Password must be enabled)

3.3.4 Technical Support Several buttons provide direct links to Technical Support functions. You can use the Tech Support button to link directly to the Lantronix Tech Support web page, the FTP-Site button will link you to the web page for downloading new firmware, manuals, and other files. The Contact Us button will link you to the Contact Information page.

3.3.5 Update Settings Click the Update Settings button to send all changed settings to the device.

CoBox-FL User Guide

3-9

Page 48

Configure

3.4 Configuring via the Setup Mode Window 3.4.1 Using a Telnet Connection To configure the unit over the network, establish a Telnet connection to port 9999. Note: If you use the Telnet to Device icon on the Device Installer Device Management window OR a serial port login to establish the connection, skip steps 1and 2. 1. From the Windows Start menu, click Run and type the following command, where x.x.x.x is the IP address and 9999 is the unit’s fixed network configuration port number. telnet x.x.x.x 9999

Note: Be sure to include a space between the IP address and 9999. 2. Click OK. 3. The Lantronix Universal Device Server window displays. *** Lantronix Universal Device Server *** Serial Number 7218033 MAC address 00:20:4A:72:46:71 Software version 04.5 (011025) Press Enter to go into Setup Mode

4. To enter the Setup Mode, you must press Enter within 5 seconds. The configuration settings will appear. See Figure 13 - Setup Mode Window. Note: The following line appears only with IAP Standard Tunnel Protocol Firmware. Model: Device Server Plus+!

(Firmware Code: AQ)

5. Select an option on the menu by entering the number of the option in the Your choice ? field and pressing Enter. 6. To enter a value for a parameter, type the value and press Enter, or to confirm a current value, just press Enter. 7. When you are finished, save the new configurations (option 9). The unit will reboot.

3-10

CoBox-FL User Guide