The text of a manual · part 4 of 15
Laser Bar Code Reader BL-500 Series User's Manual: Chapter 1 Connection and Installation
Pages 13 to 18 of 116, from Laser Bar Code Reader BL-500 Series User's Manual
The original document is the PDF (1.5 MB). This is its text as extracted, unedited; tables and drawings read best in the PDF, and each page heading opens it at that page.
For the Keyence BL-501, Keyence BL-550H, Keyence BL-551H and Keyence BL-500
Page 13
Chapter 1 Connection and Installation
Page 14
1.1 BL-500 Connections
1.1 BL-500 Connections 1.1.1 Wire colors and signal types The following wires extend from the BL-500. Solder the required wires to a connector to connect the BL-500 to a computer/controller. Wire Color
Symbol
Description
Shield Purple Brown Pink Blue
Shield RS-232C SD (TXD) RD (RXD) RS (RTS) CS (CTS)
Black
GND (SG)
Yellow White Gray Red
TIM OK NG + 5V
Signal Direction
Connect to ground (SG) Send data Receive data Request to send (always on) Request to receive Ground (common ground for respective signals) Trigger input OK output NG output + 5V power supply input, - Output Input Output Input, - Input Output Output Input
1.1.2 Power supply wiring BL-500
CAUTION
+5V
Red
GND
Black
+
5 VDC
• Be sure to match the polarities of the power supply when soldering the connections. Reversing the polarities will damage the unit. • Make sure that the power supply provides a stable 5 VDC ± 5%. If the power supply does not function in the above range, it can damage the unit. • Do not use a power cable longer that 2 meters. A long power cable can cause a voltage drop, preventing the BL-500 from starting properly. • If the power supply is UL rated, it must provide Class 2 output.
1.1.3 Connecting shielded cables For optimum reading performance, connect the BL-500’s shielded cable to GND (black) directly or through a condenser. BL-500
BL-500
Shield, Shield, Black
GND
Black
GND
Ceramic capacitor (Withdraw voltage 0.5 k to 1.0 kVDC, Capacity 0.1 μF, non-polarity)
• Using a capacitor provides a more stable operation.
1.1.4 Wiring I/O Trigger (TIM) input The trigger input is used to signal the BL-500 to start reading (Start laser emission). The trigger input is a non-voltage input (TTL input is also available).
10KΩ
5 VDC
2
4.7 KΩ
TIM
Yellow
GND
Black
Page 15
1.1 BL-500 Connections OK/NG output This output signals whether the readout data is the same as the preset data. When no preset data has been registered, the signal indicates bar code read status. It is an NPN open-collector output.
Internal circuit
BL-500
OK/NG Write/Gray
1kΩ
GND
Black
Load
+
*Rated load: 24 VDC (30 mA) max.
1.1.5 RS-232C Connections Note
This BL-500 setup software applies to port 1 and port 2 only. Communication cannot be performed with other ports. When using a D-sub 9-pin connector: Shield SD RD CS RS GND +5V
BL-500 Shield Purple Blown Blue Pink Black Red + 5 VDC
PC – Connector case 2 RD 3 SD 7 RS 8 CS 5 SG 4 ER 6 DR D-sub 9-pin (male) # 4-40 screw
Use a metallic connector housing for the D-sub 9-pin connector. Connect the shielded cable with the connector housing. When using a D-sub 25-pin connector: Shield RD SD CS RS GND +5V
BL-500 Shield Blown Purple Blue Pink Black Red + 5 VDC
Note
PC 1 FG 2 SD 3 RD 4 RS 5 CS 7 SG 6 DR 20 ER D-sub 25-pin (male) M 2..6 screw
Be sure the BL-500’s shielded cable is properly connected. Refer to “1.1.3 Connecting shielded cables” in the User’s Manual.
3
Page 16
1.1 BL-500 Connections Hints on correct use Trigger (TIM) input Set the trigger input to be long enough to allow the laser beam to cover the entire bar code. If the trigger input needs to be on for only a short period of time, select one-shot mode. Influence from mirror surface If a mirror surface (metallic surface) is near the bar code and the laser beam reflects off the mirror, the BL-500 may cause a read error. Protect the unit from the influence of a mirror surface by covering the surface or changing the bar code label position. Bar code pitch Do not place several bar codes in the field of the laser beam, unless you are in multi-label read mode (Multi 3).
If you use multi-label read mode (multi 3), the BL-500 can simultaneously read 2 to 4 bar codes in the field of the laser beam. Influence from photoelectric sensor When using a photoelectric sensor to control trigger, block the sensor beam so it does not enter the BL-500 optical pickup. The beam from the photoelectric sensor can interfere with the BL-500, deteriorating reading performance. If this case, reposition the photoelectric sensor. Object
Bar code
Light source Optical pickup
When a bar code is stained or partially missing Use a raster scan reader (BL-501/551(H)) when a bar code is stained or partially missing. This raster scan readers scan several portions of the bar code. Normal portions of the bar code, even with stained or missing portions, can be read by the BL-501/551(H).
Scans
4
Page 17
1.2 Installing the BL-500 Series
1.2 Installing the BL-500 Series Installation method Use the mounting holes on the side panel to install the unit. Using the supplied mounting brackets Install the BL-500 Series as shown in the figures below. • Select screws of the proper length by checking the thickness of the plate used for mounting. (The screws provided are for use with the mounting bracket.) • For the mounting hole diameter, see page 66. (BL-500/501/500H/501H)
M3 screws
(BL-550/551/550H/551H)
M3 screws
Optical pickup/ light source
• Use the set screw to secure the mounting bracket to the unit. • See page 68 for mounting bracket dimensions. • The mounting bracket for the front type (BL-500/501(H)) differs from that for the side type (BL-550/551(H)). The correct bracket is provided with your unit. Installation with no mounting bracket (BL-500/501/500H/501H)(BL-550/551/550H/551H)
M3 nuts
M3 nuts M3 screws
M3 screws
• Prepare M3 male screws separately. • Although the mounting holes are on both sides of the unit, only one side should be mounted. • For the mounting hole diameter, see page 66.
5
Page 18
1.2 Installing the BL-500 Series Mounting angle and mounting distance BL-500/501/500H/501H
BL-550/551/550H/551H
0 BL-50
Laser beam
BL-550
Laser beam
15° ce istan ing d Read *Reading distance = 120 mm
15° ce istan ing d d a e R *Reading distance = 95 mm
Set the angle and reading distance by referring to the read range characteristics and angle characteristics described on page 62 and 66. The allowable reading distance and angle may vary depending on the narrow bar width of the bar code, the bar code size, and the readability of the bar code. Set these parameters after performing a test read of the required bar code using the unit.
Note
Do not set the unit at an angle at which the laser beam is perpendicular to the surface of the bar code. The beam will be fully reflected into the reader, making correct reading impossible (see page 66). The laser radiation angle differs between the front and side type units. The optimal mounting angle differs depending on the type. The reading check test mode (see page 15) allows you to set the optimal reading position.
6