Page 71
APPENDIX
Page 72
A.1 Specifications
A.1 Specifications BL-500/501/550/551 Model
BL-500
BL-501
BL-550
BL-551
BL-500H
Model
BL-500SO (7034)
BL-501SO (7035)
BL-550SO (7036)
BL-551SO (7037)
BL-500HSO BL-501HSO BL-550HSO BL-551HSO (7038) (7039) (7040) (7041)
(with connector)
Type
BL-501H
Standard
Reading direction Scanning method1
Side Raster
Single
Light source
Front Raster
Class
Single
Class II
IEC/EN 60825-1:1993 +A2:2001
Class 2
DIN EN 60825-1 2001
Klasse 2
Maximum readable label width4
Raster
Single
80 to 240 mm
50 to 200 mm
35 to 170 mm
0.25 to 1.0 mm 194 mm (At 220 mm reading distance)
PCS
15 to 140 mm
0.125 to 0.5 mm
145 mm (At 175 mm reading distance)
137 mm (At 150 mm reading distance)
100 mm (At 115 mm reading distance)
0.6 or more (Reflectance of white part: 75% or more)
Scanning rate
500 scans/sec
Target code
CODE39, ITF, Industrial2-of-5, COOP2-of-5, Codabar, CODE128, EAN/UPC(A-E)
No. of readable digits
32 digits
Trigger input
Non-voltage input (contact or solid-state) *TTL input is also possible.
Rated load
24 VDC, 30 mA
Enclosure rating
IP-64
Ambient light
Sunlight: 10,000 lux., Incandescent lamp: 7,000 lux.
Current consumption Weight
Raster
670 nm
FDA (CDRH)
Readable bar width3
Side
Visible semiconductor laser
Wavelength
Reading distance2
BL-551H
High-resolution
Front Single
BL-550H
320 mA max. Approx. 210 g
Approx. 260 g
Approx. 210 g
Approx. 260 g
1. BL-501 raster width: 8.5 ± 1 mm (reading distance: 135 mm), BL-551 raster width: 8.5 ± 1 mm (reading distance: 110mm) For the raster widths of the BL-501H and BL-551H, please refer to Instruction Manual. 2. For the reading distances and Maximum readable label widths of the BL-500H, BL-501H, BL-550H, and BL-551H, please refer to Instruction Manual. 3. Readable bar width indicates the range of the narrowest readable bar. 4. For the reading distances and Maximum readable label widths of the BL-500H, BL-501H, BL-550H, and BL-551H, please refer to Instruction Manual.
60
Page 73
OK/NG output
A.1 Specifications
Output type Leakage current (at off)
NPN open collector output 0.1 mA max.
Residual voltage (at on)
0.5 V max.
Ambient temperature Relative humidity
0 to 40°C (32 to 104°F), No condensation 35 to 85%, No condensation 10 to 55 Hz, Double amplitude in X, Y and Z directions, 2 hours respectively
Vibration
5 VDC±5%1 EIA RS-232C port Start-stop ASCII 600 to 38,400 bits 7 bits/8 bits None/even/odd 1/2 bit
Serial interface
Power supply voltage Applied standard Synchronization Transmission code Baud rate Data length Parity check Stop bit
1. Use a stable power supply of 5 VDC±5%. The BL-U1 Special Power Unit is available as an option.
Note
The internal settings of the BL-500 series are stored in the EEPROM. (Rewritable up to 10,000 times)
A.1.1 Raster Scan Specifications The raster scanning method scans several portions of a bar code by swinging the laser beam optical axis vertically. This enables stable reading unaffected by a stain or defect of a bar code. For the raster width (vertical width for raster scanning), see the following table. Model
Reading distance
Raster width
BL-501/501H BL-551/551H
135 mm 110 mm
8.5 ±1 mm
Operating Environments The BL-500 Setup Software for Windows operates in the following environments: Personal Computer IBM PC/AT or compatible model (100% compatible) CPU:
80386 or higher
Memory:
4 MB or more
Floppy drive:
One or more 3.5 inch drives
RS-232C:
COM1 or COM2 port
* The BL-500 Setup Software must communicate through COM1 or COM2 port.
61
Page 74
A.2 Reading Range Characteristics (Typical)
A.2 Reading Range Characteristics (Typical) BL-500/501 Unit: mm
A B C D
0
50
Narrow bar width
Reading distance
Max. readable label width
0.25 0.33 0.5 1.0
80 to 165 80 to 175 80 to 220 80 to 240
134 142 178 194
100
150
200
250 Reading distance (mm) 100
120 (Focal length)
194
178
142
134
106
50
0
50 (Measuring conditions) •The KEYENCE standard bar code is used. •Skew :-15° •Pitch : 0° •Tilt : 0°
A (80~165) B (80~175)
100 Readable label width (mm)
C (80~220) D (80~240)
* For the reading distance measuring reference, see page 6. Note
The readable label width means a bar code length including the right and left margins (quiet zones) of a bar code. Even if a bar code is within the above reading range, it may not be read depending on the bar code quality. Set the optimum reading position based on enough reading tests. Normally, set the reading distance to 120 mm (focal length). In this case, the maximum readable label width is 106 mm.
62
Page 75
A.2 Reading Range Characteristics (Typical) BL-550/551 Unit: mm Narrow bar width
Reading distance
Max. readable label width
0.25 0.33 0.5 1.0
55 to 125 50 to 135 50 to 185 50 to 200
100 100 130 145
A B C D
50
0
100
150
200
250 Reading distance (mm)
100 95 (Focal length)
145
130
100
91
50
0
50 (Measuring conditions) •The KEYENCE standard bar code is used. •Skew : 0° •Pitch : 0° •Tilt : 0°
A (55~125) B (50~135) C (50~185)
100 Readable label width (mm)
D (50~200)
* For the reading distance measuring standard, see page 6. Note
The readable label width means a bar code length including the right and left margins (quiet zones) of a bar code. Even if a bar code is within the above reading range, it may not be read depending on the bar code quality. Set the optimum reading position based on enough reading tests. Normally, set the reading distance to 95 mm (focal length). In this case, the maximum readable label width is 91 mm.
63
Page 76
A.2 Reading Range Characteristics (Typical) BL-500H/501H Unit: mm
A B C D
Narrow bar width
Reading distance
Ma. Readable label width
0.125 0.19 0.25 0.5
75 to 110 70 to 130 55 to 145 35 to 170
89 105 117 137
0
50
100
150
200 Reading distance (mm) 100
90 (Focal length)
137
117
105
89
80
50
0
50 A (75~110) (Measuring conditions) •The KEYENCE standard bar code is used. •Skew :-15° •Pitch : 0° •Tilt : 0°
B (70~130) C (55~145) D (35~170)
100 Readable label width (mm)
* For the reading distance measuring reference, see page 6. Note
The readable label width means a bar code length including the right and left margins (quiet zones) of a bar code. Even if a bar code is within the above reading range, it may not be read depending on the bar code quality. Set the optimum reading position based on enough reading tests. Normally, set the reading distance to 90 mm (focal length). In this case, the maximum readable label width is 80 mm.
64
Page 77
A.2 Reading Range Characteristics (Typical) BL-550H/551H Unit: mm
A B C D
Narrow bar width
Reading distance
Max. readable label width
0.125 0.19 0.15 0.5
50 to 80 45 to 100 25 to 115 15 to 140
80 90 90 100
0
50
100
150 Reading distance (mm)
65 (Focal length)
A (50~80) (Measuring conditions) •The KEYENCE standard bar code is used. •Skew : 0° •Pitch : 0° •Tilt : 0°
B (45~100)
100
76 80 90
50
0
50 Readable label width (mm)
C (25~115) D (15~140)
* For the reading distance measuring standard, see page 6. Note
The readable label width means a bar code length including the right and left margins (quiet zones) of a bar code. Even if a bar code is within the above reading range, it may not be read depending on the bar code quality. Set the optimum reading position based on enough reading tests. Normally, set the reading distance to 65 mm (focal length). In this case, the maximum readable label width is 76 mm.
65
Page 78
A.3 Angular Characteristics (Typical)
A.3 Angular Characteristics (Typical) Model BL-500/501 BL-550/551 BL-500H/501H BL-550H/551H
Narrow bar width
Skew
Pitch
Tilt
0.25 mm 0.5 mm 0.25 mm 0.5 mm 0.125 mm 0.25 mm 0.125 mm 0.25 mm
-50° to -10°, +10° to +50° -60° to -10°, +10° to +60° -60° to -25°, -5° to +30° -70° to -25°, -5° to +40° -55° to -10°, +10° to +60° -60° to -10°, +10° to +65° -70° to -25°, -5° to +50° -70° to -25°, -5° to +50°
±30° ±50° ±25° ±50° ±35° ±55° ±35° ±55°
±45° ±45° ±45° ±45° ±15° ±35° ±15° ±35°
(Measuring conditions) Bar code: KEYENCE standard bar code Reading distance: 120 mm (BL-500/501)/95 mm (BL-550/551) 90 mm (BL-500H/501H)/65 mm (BL-550H/551H)
CAUTION
The skew angles of -10° to +10° (BL-500/501(H)) or -25° to -5° (BL-550/551(H)) are the specular reflection range. In this range, bar codes cannot be read, or reading error may occur. Be sure not to mount the BL500 series at the above skew angles. Skew +
0°
+
–
0° –
BL-550(H) BL-551(H) BL-500(H) BL-501(H)
Pitch
Tilt +
+ 0° 0°
–
Laser beam
66
–
Page 79
A.4 Dimensions
A.4 Dimensions BL-500/501/500H/501H Laser beam 50 11.8
Laser transmitter 3.5 8.5 KEYENCE
ø5.3 Cable length: 1.8 m
40
33
42
4.5
28
2 x ø3.3 (mounting hole)
BL-550/551/550H/551H 80 11.8
°
15
3.5
Laser beam
Laser transmitter 18
KEYENCE
ø5.3 Cable length: 1.8 m
40
33
42
34.5
28
2 x ø3.3 (mounting hole)
67
Page 80
A.4 Dimensions BL-500/501/500H/501H (with mounting bracket) 10.5
2-R2.25
28
10.5 ø4.3 mounting hole
34 R19
2
16
29
50°
41 2
61
BL-550/551/550H/551H (with mounting bracket) 49 5 4.5 16
37.5 3
4.5
11
9.5 3
47 2
48
68