Page 71

APPENDIX

Page 72

A.1 Specifications

A.1 Specifications BL-500/501/550/551 Model

BL-500

BL-501

BL-550

BL-551

BL-500H

Model

BL-500SO (7034)

BL-501SO (7035)

BL-550SO (7036)

BL-551SO (7037)

BL-500HSO BL-501HSO BL-550HSO BL-551HSO (7038) (7039) (7040) (7041)

(with connector)

Type

BL-501H

Standard

Reading direction Scanning method1

Side Raster

Single

Light source

Front Raster

Class

Single

Class II

IEC/EN 60825-1:1993 +A2:2001

Class 2

DIN EN 60825-1 2001

Klasse 2

Maximum readable label width4

Raster

Single

80 to 240 mm

50 to 200 mm

35 to 170 mm

0.25 to 1.0 mm 194 mm (At 220 mm reading distance)

PCS

15 to 140 mm

0.125 to 0.5 mm

145 mm (At 175 mm reading distance)

137 mm (At 150 mm reading distance)

100 mm (At 115 mm reading distance)

0.6 or more (Reflectance of white part: 75% or more)

Scanning rate

500 scans/sec

Target code

CODE39, ITF, Industrial2-of-5, COOP2-of-5, Codabar, CODE128, EAN/UPC(A-E)

No. of readable digits

32 digits

Trigger input

Non-voltage input (contact or solid-state) *TTL input is also possible.

Rated load

24 VDC, 30 mA

Enclosure rating

IP-64

Ambient light

Sunlight: 10,000 lux., Incandescent lamp: 7,000 lux.

Current consumption Weight

Raster

670 nm

FDA (CDRH)

Readable bar width3

Side

Visible semiconductor laser

Wavelength

Reading distance2

BL-551H

High-resolution

Front Single

BL-550H

320 mA max. Approx. 210 g

Approx. 260 g

Approx. 210 g

Approx. 260 g

1. BL-501 raster width: 8.5 ± 1 mm (reading distance: 135 mm), BL-551 raster width: 8.5 ± 1 mm (reading distance: 110mm) For the raster widths of the BL-501H and BL-551H, please refer to Instruction Manual. 2. For the reading distances and Maximum readable label widths of the BL-500H, BL-501H, BL-550H, and BL-551H, please refer to Instruction Manual. 3. Readable bar width indicates the range of the narrowest readable bar. 4. For the reading distances and Maximum readable label widths of the BL-500H, BL-501H, BL-550H, and BL-551H, please refer to Instruction Manual.

60

Page 73

OK/NG output

A.1 Specifications

Output type Leakage current (at off)

NPN open collector output 0.1 mA max.

Residual voltage (at on)

0.5 V max.

Ambient temperature Relative humidity

0 to 40°C (32 to 104°F), No condensation 35 to 85%, No condensation 10 to 55 Hz, Double amplitude in X, Y and Z directions, 2 hours respectively

Vibration

5 VDC±5%1 EIA RS-232C port Start-stop ASCII 600 to 38,400 bits 7 bits/8 bits None/even/odd 1/2 bit

Serial interface

Power supply voltage Applied standard Synchronization Transmission code Baud rate Data length Parity check Stop bit

1. Use a stable power supply of 5 VDC±5%. The BL-U1 Special Power Unit is available as an option.

Note

The internal settings of the BL-500 series are stored in the EEPROM. (Rewritable up to 10,000 times)

A.1.1 Raster Scan Specifications The raster scanning method scans several portions of a bar code by swinging the laser beam optical axis vertically. This enables stable reading unaffected by a stain or defect of a bar code. For the raster width (vertical width for raster scanning), see the following table. Model

Reading distance

Raster width

BL-501/501H BL-551/551H

135 mm 110 mm

8.5 ±1 mm

Operating Environments The BL-500 Setup Software for Windows operates in the following environments: Personal Computer IBM PC/AT or compatible model (100% compatible) CPU:

80386 or higher

Memory:

4 MB or more

Floppy drive:

One or more 3.5 inch drives

RS-232C:

COM1 or COM2 port

* The BL-500 Setup Software must communicate through COM1 or COM2 port.

61

Page 74

A.2 Reading Range Characteristics (Typical)

A.2 Reading Range Characteristics (Typical) BL-500/501 Unit: mm

A B C D

0

50

Narrow bar width

Reading distance

Max. readable label width

0.25 0.33 0.5 1.0

80 to 165 80 to 175 80 to 220 80 to 240

134 142 178 194

100

150

200

250 Reading distance (mm) 100

120 (Focal length)

194

178

142

134

106

50

0

50 (Measuring conditions) •The KEYENCE standard bar code is used. •Skew :-15° •Pitch : 0° •Tilt : 0°

A (80~165) B (80~175)

100 Readable label width (mm)

C (80~220) D (80~240)

* For the reading distance measuring reference, see page 6. Note

The readable label width means a bar code length including the right and left margins (quiet zones) of a bar code. Even if a bar code is within the above reading range, it may not be read depending on the bar code quality. Set the optimum reading position based on enough reading tests. Normally, set the reading distance to 120 mm (focal length). In this case, the maximum readable label width is 106 mm.

62

Page 75

A.2 Reading Range Characteristics (Typical) BL-550/551 Unit: mm Narrow bar width

Reading distance

Max. readable label width

0.25 0.33 0.5 1.0

55 to 125 50 to 135 50 to 185 50 to 200

100 100 130 145

A B C D

50

0

100

150

200

250 Reading distance (mm)

100 95 (Focal length)

145

130

100

91

50

0

50 (Measuring conditions) •The KEYENCE standard bar code is used. •Skew : 0° •Pitch : 0° •Tilt : 0°

A (55~125) B (50~135) C (50~185)

100 Readable label width (mm)

D (50~200)

* For the reading distance measuring standard, see page 6. Note

The readable label width means a bar code length including the right and left margins (quiet zones) of a bar code. Even if a bar code is within the above reading range, it may not be read depending on the bar code quality. Set the optimum reading position based on enough reading tests. Normally, set the reading distance to 95 mm (focal length). In this case, the maximum readable label width is 91 mm.

63

Page 76

A.2 Reading Range Characteristics (Typical) BL-500H/501H Unit: mm

A B C D

Narrow bar width

Reading distance

Ma. Readable label width

0.125 0.19 0.25 0.5

75 to 110 70 to 130 55 to 145 35 to 170

89 105 117 137

0

50

100

150

200 Reading distance (mm) 100

90 (Focal length)

137

117

105

89

80

50

0

50 A (75~110) (Measuring conditions) •The KEYENCE standard bar code is used. •Skew :-15° •Pitch : 0° •Tilt : 0°

B (70~130) C (55~145) D (35~170)

100 Readable label width (mm)

* For the reading distance measuring reference, see page 6. Note

The readable label width means a bar code length including the right and left margins (quiet zones) of a bar code. Even if a bar code is within the above reading range, it may not be read depending on the bar code quality. Set the optimum reading position based on enough reading tests. Normally, set the reading distance to 90 mm (focal length). In this case, the maximum readable label width is 80 mm.

64

Page 77

A.2 Reading Range Characteristics (Typical) BL-550H/551H Unit: mm

A B C D

Narrow bar width

Reading distance

Max. readable label width

0.125 0.19 0.15 0.5

50 to 80 45 to 100 25 to 115 15 to 140

80 90 90 100

0

50

100

150 Reading distance (mm)

65 (Focal length)

A (50~80) (Measuring conditions) •The KEYENCE standard bar code is used. •Skew : 0° •Pitch : 0° •Tilt : 0°

B (45~100)

100

76 80 90

50

0

50 Readable label width (mm)

C (25~115) D (15~140)

* For the reading distance measuring standard, see page 6. Note

The readable label width means a bar code length including the right and left margins (quiet zones) of a bar code. Even if a bar code is within the above reading range, it may not be read depending on the bar code quality. Set the optimum reading position based on enough reading tests. Normally, set the reading distance to 65 mm (focal length). In this case, the maximum readable label width is 76 mm.

65

Page 78

A.3 Angular Characteristics (Typical)

A.3 Angular Characteristics (Typical) Model BL-500/501 BL-550/551 BL-500H/501H BL-550H/551H

Narrow bar width

Skew

Pitch

Tilt

0.25 mm 0.5 mm 0.25 mm 0.5 mm 0.125 mm 0.25 mm 0.125 mm 0.25 mm

-50° to -10°, +10° to +50° -60° to -10°, +10° to +60° -60° to -25°, -5° to +30° -70° to -25°, -5° to +40° -55° to -10°, +10° to +60° -60° to -10°, +10° to +65° -70° to -25°, -5° to +50° -70° to -25°, -5° to +50°

±30° ±50° ±25° ±50° ±35° ±55° ±35° ±55°

±45° ±45° ±45° ±45° ±15° ±35° ±15° ±35°

(Measuring conditions) Bar code: KEYENCE standard bar code Reading distance: 120 mm (BL-500/501)/95 mm (BL-550/551) 90 mm (BL-500H/501H)/65 mm (BL-550H/551H)

CAUTION

The skew angles of -10° to +10° (BL-500/501(H)) or -25° to -5° (BL-550/551(H)) are the specular reflection range. In this range, bar codes cannot be read, or reading error may occur. Be sure not to mount the BL500 series at the above skew angles. Skew +

0°

+

–

0° –

BL-550(H) BL-551(H) BL-500(H) BL-501(H)

Pitch

Tilt +

+ 0° 0°

–

Laser beam

66

–

Page 79

A.4 Dimensions

A.4 Dimensions BL-500/501/500H/501H Laser beam 50 11.8

Laser transmitter 3.5 8.5 KEYENCE

ø5.3 Cable length: 1.8 m

40

33

42

4.5

28

2 x ø3.3 (mounting hole)

BL-550/551/550H/551H 80 11.8

°

15

3.5

Laser beam

Laser transmitter 18

KEYENCE

ø5.3 Cable length: 1.8 m

40

33

42

34.5

28

2 x ø3.3 (mounting hole)

67

Page 80

A.4 Dimensions BL-500/501/500H/501H (with mounting bracket) 10.5

2-R2.25

28

10.5 ø4.3 mounting hole

34 R19

2

16

29

50°

41 2

61

BL-550/551/550H/551H (with mounting bracket) 49 5 4.5 16

37.5 3

4.5

11

9.5 3

47 2

48

68