The text of a manual · part 3 of 12
EasyCoder PL4 Printer User's Guide: Charging the Battery
Pages 8 to 12 of 65, from EasyCoder PL4 Printer User's Guide
The original document is the PDF (2.5 MB). This is its text as extracted, unedited; tables and drawings read best in the PDF, and each page heading opens it at that page.
For the Intermec PL4
Page 8
Belt clip
Charger jack
Battery
PL4U006.eps
4 Press the battery into the printer until it locks in place. When the battery is first installed, the Control Panel indicators may briefly turn on and then go off which indicates the battery is not fully charged. For help, see “Using the Single Battery Charger” and “Understanding the Control Panels” later in this guide.
Charging the Battery This section explains how to use the following chargers: • Single battery charger (P/N AT15759-1) that comes with an AC contact adapter for the U.S.A. (110V). You can also order a set of international contact adapters (P/N AN16740-1). • 4-pack battery charger (P/N AT16305-2) that is designed to charge up to four PL4 batteries simultaneously. You must remove the batteries from the printer to charge them.
Using the Single Battery Charger Using the single battery charger, you can charge the battery while it is in the printer or when it is removed. If the battery is in the printer, the printer must be turned off to charge the battery.
8
EasyCoder PL4 Printer User’s Guide
Page 9
Do not attempt to charge batteries with the charger while printing. Attempting to print while charging can result in improperly charged batteries. Attention: Ne pas essayer de charger des batteries à l’aide du chargeur pendant l’impression. Toute tentative d’impression pendant le processus de charge risque de produire des batteries mal chargées. To use the single battery charger
1 (Optional) Install the battery in the printer. For help, see the previous section.
2 Insert the AC contact adapter into the single battery charger. 3 Plug the single battery charger into an AC wall receptacle. 4 Insert the charge cable into the charger jack. Charger jack Single battery charger
AC contact adapter Charger LED
PL4U008.eps
EasyCoder PL4 Printer User’s Guide
9
Page 10
5 The charger LED will indicate the status of the charger as follows: Charger LED Status
Description
Steady on light
The battery is undergoing a fast charge.
Slow blinking light
The charger is in trickle mode. The battery is ready for use.
Rapidly blinking light
There is a problem with the battery. It may have an internal short or its charge monitoring circuitry may be malfunctioning. Do not use the battery.
Using the 4-Pack Charger Please follow these guidelines when situating the 4-pack charger: • Do not place the charger in locations where liquids or metallic objects may be dropped into the charging bays. • Do not block the ventilating slots on the top and bottom covers. • Make sure the charger is plugged into a power source that stays on for overnight charging. To charge the battery with the 4-pack charger
1 Make sure the charger has been installed properly. See the guide that came with your 4-pack charger for help. The power indicator on the front panel should be on.
10
EasyCoder PL4 Printer User’s Guide
Page 11
Power supply
Fast Faul t
Char ge
Full
Char ge
Read y Fast Faul t
Char ge
Full
Char ge
Read y Fast
Amber indicator
Faul t
Char ge
Full
Char ge
Read y Fast Faul
Green indicator
Char ge
Full t
Char ge
Read Powe y r
Charger bay PL4U009.eps
Power indicator
2 Plug a battery into any one of the four charger bays, noting the orientation of the battery.
3 Slide the battery into the charging bay until it stops and then rock the battery back until it snaps into place. The amber indicator directly under the battery being charged will turn on if the battery is properly installed. The indicators under the battery will allow you to monitor the charging process per the next table. Amber
Green
Battery Status
On
Off
Charging
On
Flashing
80% charged (OK to use)
Off
On
Completely charged
Flashing
Off
Fault
EasyCoder PL4 Printer User’s Guide
11
Page 12
Note: A fault condition is caused by a problem with the battery. The charger may indicate a fault because the battery is too hot or cold to charge reliably. Charge batteries between 0°C to 45°C (32°F to 113°F). If the amber indicator starts flashing on the second attempt, the battery should be discarded. 4-Pack Charger Cycle Times for PL4 Batteries Percentage Charged
Time
Battery 80% Charged
2.5 hrs.
Battery Fully Charged
5 hrs.
These times are for completely discharged batteries. Batteries that are only partially discharged will take less time to reach their charged state. You can use batteries that have reached 80% of their charge capacity, but we recommend you allow the batteries to reach a full charge to maintain maximum battery life. The 4-pack battery charger has a safety feature that stops charging a battery after 6 hours regardless of its charge state. Do not allow your battery charger to come in contact with any conductive material. It creates a short circuit that could cause burns and other injuries or could start a fire. Use of any charger not approved specifically by Intermec for use with its batteries could cause damage to the battery pack or the printer and will void the warranty. Attention: Le chargeur de batterie ne doit pas entrer en contact avec un matériel conducteur. Dans le cas contraire, un court-circuit risque d’entraîner des brûlures et d’autres blessures ou de provoquer un incendie. L’emploi d’un chargeur non approuvé de façon spécifique par Intermec pour utilisation avec ses batteries risque d’endommager le bloc-batterie ou l’imprimante et annulera la garantie.
12
EasyCoder PL4 Printer User’s Guide