Page 17
JANUS 2020 Communications Dock Quick Reference Guide
Reference This section provides reference material on these topics: •
Operating environment information
•
How to daisy chain two or more communications docks
•
Battery status lights
•
Battery troubleshooting
•
Pin assignments for the dock connectors
Operating Environment Temperature Battery Charging Reader Operating Storage without a battery pack Storage with a battery pack
50°F to 104°F (10°C to 40°C) -4°F to 122°F (-20°C to 50°C) -4°F to 140°F (-20°C to 60°C) -4°F to 95°F (-20°C to 35°C)
Note: The reader operating temperature range applies when the reader is operating in the communications dock.
Humidity Non-condensing humidity: Operating Storage
10% to 90% relative humidity 10% to 90% relative humidity
How to Daisy Chain the Communications Docks You can connect two or more communications docks together in a daisy chain, then connect the string of docks to a single serial port on a host computer. You can use the daisy chain to download a program to each JANUS 2020 reader in its dock. Only one RS-232 or RS-422 device (either the host computer or one JANUS 2020 reader) can transmit at a time. To daisy chain the docks 1. Connect a cable from the network port on one dock to the auxiliary port on the next dock. 2. Repeat Step 1 to include each additional dock in the chain. 3. Connect the last dock at either end of the chain to the host computer or another device. The dock you choose depends upon which port you are using (network or auxiliary) to connect to the host computer or device.
17
Page 18
JANUS 2020 Communications Dock Quick Reference Guide
Cables for Daisy Chaining If you are using an RS-232 interface to the host computer, use straight-through cables to connect the docks in the chain. If you are using an RS-422 interface, use a 5-pin cable with pins 7, 13, 14, 16, 19 straight-through to connect the docks in the chain.
Battery Status Lights The battery LEDs allow you to monitor the status of the battery pack that is inserted in the battery slot. The next table shows the possible lighting combinations that you may see and the status each indicates.
The dock or charger is waiting for a battery, or there is no power to the dock or charger. The battery is about to begin charging. The battery is charging. The battery is charged and ready. The discharge button has been pushed and the slot is waiting for a battery to discharge. The battery is discharging. The battery did not charge in the allotted time. The battery may be damaged. The battery has poor contact with the battery slot contacts or the battery may be damaged. (Discharge and Ready LEDs flash alternately) A battery has been inserted that is not supported by the dock or charger. (all three LEDs flash in order) The battery temperature is out of range. (Discharge and Ready LEDs flash alternately with Charge LED) A battery has been inserted that may be damaged. (all three LEDs flash together) = off
= on
= flashing
Note: When an LED flashes, it is either a solid, intermittently flashing light, or a dim, rapidly flashing light.
18
2020Q.006
Page 19
JANUS 2020 Communications Dock Quick Reference Guide
Battery Troubleshooting Battery LEDs
Problem
Solution
Discharge and Ready LEDs flash alternately with Charge LED.
The battery pack must always be between 50°F and 104°F (10°C and 40°C) to begin charging. If the battery pack temperature is outside this range, the dock stops charging the battery pack.
Remove the battery pack from the slot and make sure the battery pack is within the temperature range before you try to charge it again. To prevent temperature problems, keep the communications dock in a room that is within the temperature range and let the battery packs cool down before charging them.
There is bad contact between the battery pack and the dock battery slot, or the battery is damaged.
Take the battery pack out of the slot and disconnect the power supply to the dock. Use rubbing alcohol and cotton swabs to clean the contact points on the battery pack and in the dock battery slot. Connect the power supply to the dock and repeat the procedure to charge or discharge the battery pack. If that does not fix the problem, your battery pack may be damaged.
The dock cannot raise the battery voltage to an adequate level. All three battery LEDs continue to flash at the same time until the battery pack is removed.
There may be something wrong with the battery pack. Remove the battery pack and then put the same battery back into the slot. If all three LEDs flash again, you have a bad battery pack that needs to be replaced.
The dock cannot fully charge the battery pack within 2.5 hours.
There may be something wrong with the battery pack. Remove the battery pack and try discharging and then charging the battery pack. If the Ready LED flashes again, you have a bad battery pack that needs to be replaced.
You inserted a battery pack that is not supported by the communications dock.
Remove the battery pack from the slot. Insert a J2020 battery pack. You can only charge J2020 battery packs in the dock.
Discharge and Ready LEDs flash alternately.
All three LEDs flash at the same time.
The Ready LED flashes.
All three LEDs flash in order.
19
Page 20
JANUS 2020 Communications Dock Quick Reference Guide
Pin Assignments for the Dock Connectors The two ports on the communications dock use 25-pin D-style connectors. The following pinouts are used for the Network and Auxiliary connectors. The network connector is a DTE interface and the auxiliary connector is a DCE interface.
Network Connector
(1) Protective ground (2) Transmitted data (out) (3) Received data (in) (4) Request to send (out) (5) Clear to send (in) (6) Data set ready (in) (7) Signal ground (8) Received line signal detector (in)
(14) Output Circuit A (out) (15) Transmitter clock (in) (16) Input Circuit A (in) (17) Receiver clock (in) (19) Output Circuit B (out) (20) Data terminal ready (out) (22) Ring indicator (in)
(11) Reserved (13) Input Circuit B (in) 2020Q.007
Auxiliary Connector
(1) Protective ground (2) Transmitted data (in) (3) Received data (out) (4) Request to send (in) (5) Clear to send (out) (6) Data set ready (out) (7) Signal ground (8) Received line signal detector (out)
(14) Input Circuit A (in) (15) Transmitter clock (out) (16) Output Circuit A (out) (17) Receiver clock (out) (19) Input Circuit B (in) (20) Data terminal ready (in) (22) Ring indicator (out)
(11) Reserved (13) Input Circuit B (out) 2020Q.008
20
Page 21
JANUS 2020 Communications Dock Quick Reference Guide
Note: You place the JANUS 2020 reader in the dock to communicate with the devices that are connected to the dock ports. When you turn the reader on and place it in the reader slot, the DTR/DSR signals on the selected dock ports are set high to indicate to the host computer that the reader is in the dock. If you remove the reader from the slot while a device is communicating with the reader, the DTR/DSR signals on the dock ports go low to indicate to the host computer that the reader has been removed. The DTR/DSR signals on the dock ports are also set high when the dock ports are configured to talk to each other, and devices are connected and active on the ports.
21