j AUT m AUT p AUT A S) AUT Vv ALITA y AUT aL V%
C-22 k AUT n MUTA q AUT t AUT Ww ALATA
Zz *47%
| MUTA O AUT *4O* r MUTT 0) AUT xX *4X*
Page 502
NF
BC Configuration and Full ASCII Charts
C
Scanning Bar Codes to Select Menu Options You can scan the next bar code labels to select options and move around in these menu applications: •
Interactive Configuration application (IC.EXE)
•
Communications Manager
•
IRL Desktop
The bar codes in this section use the four-digit hexadecimal key code value for each key. You can create your own bar codes for every key by using the same syntax. For help, see “Creating Your Own Key Code Bar Code Labels” later in this appendix. Enter
Esc
*..1C0D*
*..011B*
Cursor Up
Cursor Down
*..48E0*
*..50E0*
Cursor Left
Cursor Right
*..1C0D*
*..48E0*
*..4BE0*
*..011B*
*..50E0*
*..4DE0*
*..4BE0*
*..4DE0*
Page Up
Page Down
*..49E0*
*..51E0*
Home
End
*..47E0*
*..4FE0*
Insert
Delete
*..49E0*
*..47E0*
*..52E0* *..52E0*
*..51E0*
*..4FE0*
*..53E0*
*..53E0*
C-23
Page 503
JANUS 2020 Hand-Held Computer User’s Manual (4MB) NFBC
Scanning Bar Codes to Select Menu Options (continued) Tab
Backtab
*..0F09*
*..0F00*
*..0F09*
*..0F00*
Backspace
F1
*..0E08* *..0E08*
*..3B00*
*..3B00*
Creating Your Own Key Code Bar Code Labels You can use each key’s four-digit hexadecimal value to: •
Insert the value into the keypad buffer to use in IC.EXE, Communications Manager, or IRL Desktop.
•
Redefine scanned characters to a keystroke equivalent to modify the reader’s key code look-up table.
You can create your own bar code label for each key by using this syntax: ..data where data is the four-digit hexadecimal key code value. Use the Key Code Table to find each key’s four-digit hexadecimal value. For help, see “Key Codes” earlier in this appendix. For example, the hexadecimal value for the uppercase letter B is 3042. Use this syntax to create a bar code label: ..3042
Create this bar code label: B
*..3042* *..3042*
C-24
Page 504
NF
BC
D Software Utility Reference
Page 505
NF
BC
Page 506
NF
BC Software Utility Reference
D
This appendix describes Interlnk, INTERLNK.EXE, INTERSVR.EXE, POWER.EXE, and the Auto-Loader batch files.
Interlnk With Interlnk, you can easily transfer files between your reader and a host computer or another reader. You can also make all the drives on one computer appear as if they are physically located on the other, so that you have unrestricted access to the contents of all the drives. The device running Interlnk is the client and is used to enter commands. The device responding to commands is the server. For help installing and running Interlnk, see “Running Interlnk to Transfer Files” in Chapter 6. The command to begin running Interlnk is: Syntax:
interlnk [client:=][server:] where:
Notes:
client specifies the letter of the client drive that is redirected to a drive on the server. The drive must be one that was redirected when you started Interlnk.
server specifies the letter of the drive on the Interlnk server that is redirected. The drive must be one listed under This Computer (Server) in the Interlnk Server Status screen.
Installing the INTERLNK.EXE device driver You must load the INTERLNK.EXE device driver into memory before you can use the Interlnk command. For help, see the next section. Displaying the status To display Interlnk’s current status, type the command on the client without including the client:=server: parameter. Canceling redirection on a drive To cancel redirection of a client drive to a server drive, specify only the client drive and the equal sign (=) in the Interlnk command.
Examples:
To redirect drive F and G on the client to drive D and E on the server: interlnk f=d g=e
To cancel the redirection of client drive G: interlnk g=
D-3
Page 507
JANUS 2020 Hand-Held Computer User’s Manual (4MB) NFBC
INTERLNK.EXE This device driver redirects requests for operations on Interlnk drives or printer ports to Intersvr drives or printer ports. You must load this device driver in the CONFIG.SYS file of the device running Interlnk (the client). Add a command to the client’s CONFIG.SYS that follows this syntax: Syntax:
device=[drive:][path\]interlnk.exe [/drives:n] [/noprinter] [/com[:][n | address]] [/auto] [/noscan] [/low ] /baud:rate][/v] where: drive:path specifies the location of the INTERLNK.EXE file
/drives:n specifies the number of drives to redirect: to redirect printers only 0 to redirect one drive 1 to redirect two drives 2 to redirect three drives (default) 3 and so on.
/noprinter specifies not to redirect printers. By default, Interlnk redirects all available printer ports.
/com:n /com:address identifies the serial COM port that is connected to the server by specifying either the number (n) or address (address) of the port. If you omit n and address, Intersvr searches all serial ports and uses the first port that it finds connected to the client. If you specify the /com switch, the server searches only for serial ports. By default, all serial ports are scanned.
D-4
/auto loads the INTERLNK.EXE device driver in memory only if the client can establish a connection with the server when the client starts up. By default, Interlnk is loaded even if the client cannot establish a connection with the server.
/noscan loads the INTERLNK.EXE device driver in memory, but prevents a connection between client and server from being established. By default, the client tries to establish a connection with the server as soon as you load INTERLNK.EXE.
/low loads the INTERLNK.EXE device driver into conventional memory even if upper memory is available. By default, INTERLNK.EXE is loaded into upper memory if DOS 5.0 upper memory block support and memory is available.
Page 508
NF
BC Software Utility Reference
D
INTERLNK.EXE (continued)
Notes:
/baud:rate sets a maximum baud rate for serial communication. Type 9600, 19200, 38400, 57600, or 115200. The default is 115200.
/v prevents conflicts with a computer’s timer. Include this switch if you have a serial connection between computers and one of them stops running when you use Interlnk to access a drive or printer port.
Position of the Interlnk command in the CONFIG.SYS file The position of the device command that loads INTERLNK.EXE in the CONFIG.SYS can affect pre-existing drive assignments. For example, suppose your computer includes a floppy disk drive (A), two hard disk drives (C and D), and two RAM drives (E and F). If you load the INTERLNK.EXE device driver before creating the RAM drives and you choose to redirect three drives, Interlnk assigns letters E, F, and G to the redirected drives, and letters H and I to the RAM drives. To prevent this situation from happening, load INTERLNK.EXE last in your CONFIG.SYS file. Calculating the number of drives to redirect When you add the INTERLNK.EXE command to the host computer’s CONFIG.SYS, you should set the /drives option to at least seven drives. The reader contains five default drives (C, D, E, F, G), and Interlnk assumes two more (A and B). If you specify fewer than seven drives, Interlnk will not redirect all the reader’s drives. You need more than seven drives if the reader contains more than one physical RAM drive. Saving memory The Interlnk device driver loads all of its code into memory. You can save memory by specifying the /noprinter or /com switch. If you specify the /noprinter switch, the Interlnk program does not load code that redirects printers. If you specify the /com switch, the program does not load code that supports parallel ports. Intermec recommends using the /noprinter and /com switches when INTERLNK.EXE is loaded on the reader. Using a serial mouse with Microsoft Windows If you are using a serial mouse with Microsoft Windows, specify the /com switch to designate a COM port other than the one the mouse is using. DOS version Some features of DOS may not be available to the client computer if you are running a different DOS version on your Interlnk server. For example, if you have large partitions on the server and are running DOS 3.0 on the client, the partitions are not available to the client because DOS 3.0 does not support them. Running an application located on the server If you use Interlnk to run an application located on the server, make sure the application is configured for the computer you have designated as the client.
D-5
Page 509
JANUS 2020 Hand-Held Computer User’s Manual (4MB) NFBC
INTERLNK.EXE (continued) Limitations CHKDSK DISKCOMP DISKCOPY
These commands do not work on devices running Interlnk: FORMAT MIRROR SYS
UNDELETE UNFORMAT
Interlnk does not redirect network, CD-ROM drives, or any other device that uses a redirection interface. For example, you cannot access a network drive that was redirected before Interlnk was started. Examples:
If the Interlnk files are located in the INTERLNK directory on the host computer’s drive C and you need to specify seven drives so that drives C through G on the reader will be redirected, add this line to the CONFIG.SYS file on the reader: device=c:\interlnk\interlnk.exe /drives:7
If the Interlnk files are located in the root directory on drive D of the reader, you used the serial port to connect to another computer, and you want to start Interlnk without having the printers redirected, add this line to the CONFIG.SYS file on the reader: device=d:\interlnk.exe /com /noprinter /drives:7
To make Interlnk use a non-standard COM port whose address is 3F8, add this line to your CONFIG.SYS file on the reader: device=d:\interlnk.exe /com:3F8 /drives:7
D-6
Page 510
NF
BC Software Utility Reference
D
Intersvr Interlnk is loaded on the device designated as the client. The device running Intersvr is called the server. The server responds to commands typed on the client. When you run Intersvr in conjunction with Interlnk, it provides serial file transfer capability through redirected drives, and printing through redirected printer ports. For help installing and running Intersvr, see “Running Interlnk to Transfer Files” in Chapter 6. Type this command to begin running Intersvr: Syntax:
intersvr [drive:] [/x=drive:] [/com:n | address] [/baud:rate][/b][/v] where: drive:
specifies the letter of a drive to be redirected. By default, all drives are redirected.
/x=drive specifies a drive that is not redirected. By default, all drives are redirected.
/com:n /com:address identifies the serial COM port that is connected to the server by specifying either the number (n) or address (address) of the port. If you omit n and address, Intersvr searches all serial ports and uses the first port that it finds connected to the client. If you specify the /com switch, the server searches only for serial ports. By default, all serial ports are scanned.
Notes:
/baud:rate sets a maximum serial baud rate. Type 9600, 19200, 38400, 57600, or 115200. The default is 115200.
/b displays the Interlnk Server Status screen in black and white. Use this switch if you are having problems reading your monochrome monitor.
/v prevents conflicts with a computer’s timer. Specify this switch if you have a serial connection between computers and one of them stops running when you use Interlnk to access a drive or printer port.
Specifying the order of drives Interlnk redirects drives in the order you specify. The first server drive specified is redirected to the first available client drive, the second server drive specified is redirected to the second available client drive, and so forth.
D-7