Page 481

NF

BC

Page 482

NF

BC Configuration and Full ASCII Charts

C

This appendix includes reference tables you can use when configuring communications protocols and the key code look-up table on the reader. It also contains a full ASCII chart and charts of Code 39 bar code labels that you can scan with the JANUS 2020 reader.

Entering ASCII Control Characters You may need to enter ASCII control characters to configure these parameters in IC.EXE or the Communications Manager screens: •

Preambles and postambles. You can include ASCII control characters in postambles and preambles.

•

Protocol characters, such as EOR and EOM. For some communications protocols, you must set the protocol character to an ASCII control character.

To enter ASCII control characters for preambles and postambles 1. Decide which ASCII control character you want to set for the preamble or postamble. Use the next table to find the character and the escape sequence. ASCII Control Character

Escape Sequence

\

Backslash

\\

BEL

Bell

\a

BS

Backspace

\b

CR

Carriage Return

\r

FF

Form Feed

\f

HT

Horizontal Tab

\t

LF

Line Feed

\n

Other ASCII control characters

\xhh where hh is the two-digit hexadecimal number for the ASCII control character.

If the table does not include the ASCII control character, you must use the Full ASCII Table later in this appendix to identify the two-digit hexadecimal number for the control character. 2. Use IC.EXE to configure a preamble or postamble. Move the cursor to the field for the preamble or postamble. For help using IC.EXE, see Chapter 5, “Configuring the Reader.”

C-3

Page 483

JANUS 2020 Hand-Held Computer User’s Manual (4MB) NFBC

3. Type the characters you identified in Step 1. Here are two examples: •

You find Carriage Return (CR) Line Feed (LF) in the Entering ASCII Control Characters for Preambles and Postambles table. The CR is \r and the LF is \n. You type this value: \r\n

•

You find ETX in the Full ASCII Table and learn that 03 is the two-digit hex number for ETX. You type \x followed by the hex number: \x03

Note: If you type the hex number for an ASCII character above 7F hex (128 decimal), the reader displays the extended ASCII character instead of its numeric value in the dialog box. To enter ASCII control characters for protocol characters 1. Decide which ASCII control character you want to set for the protocol character. Use the next table to find the character and the key sequence. 2. Use IC.EXE or Communications Manager to configure a communications protocol. Move the cursor to the field for the protocol character. For help using IC.EXE, see Chapter 5, “Configuring the Reader.” For help using Communications Manager, see Chapter 6, “Networking the Reader.”

>! =

3. Press the key sequence you identified in Step 1. For example, to enter the ASCII character STX, press . The word <STX> appears in the field. Note: To disable a protocol character, move the cursor to the space next to the protocol character and press .

C-4

Page 484

NF

BC Configuration and Full ASCII Charts

C

Entering ASCII Control Characters for Protocol Characters ASCII Control Character ACK BEL BS CAN CR DC1 DC2 DC3 DC4 DLE EM

>% >& >' >7 >, >0 >1 >2 >3 >/ >8

Key Sequence

ASCII Control Character ENQ EOT ESC ETB ETX FF FS GS HT LF NAK

>$ ># < >6 >" >+ >G >H >( >) >4

Key Sequence

ASCII Control Character NUL RS SI SO SOH STX SUB SYN US VT

>K >I >. >> >! >9 >5 >J >*

Key Sequence

Note: IRL does not use these key sequences for the ASCII control characters FS, GS, RS, US, and NUL. The Interactive Configuration application (IC.EXE) and Communications Manager do use them.

C-5

Page 485

JANUS 2020 Hand-Held Computer User’s Manual (4MB) NFBC

Configuration Options for User-Defined Protocol User-Defined protocol supports 24 different configurations. The six key parameters that determine the User-Defined configuration are POL, SEL, RES, REQ, AFF, and NEG. The next table lists all the valid combinations for these six User-Defined protocol parameters. The most common User-Defined configurations have been named and are listed first in the table. User-Defined Configuration

POL

SEL

RES

REQ

AFF

NEG

User-Defined Point-to-Point protocol ACK/NAK protocol ACK/NAK protocol with timeout One-character solicitation with handshake User-Defined Polling Mode D protocol Unnamed protocol Unnamed protocol Unnamed protocol Unnamed protocol Unnamed protocol Unnamed protocol Unnamed protocol Unnamed protocol Unnamed protocol Unnamed protocol Unnamed protocol Unnamed protocol Unnamed protocol Unnamed protocol Unnamed protocol Unnamed protocol Unnamed protocol Unnamed protocol Unnamed protocol, - - X X, - - - - - - - - X X X X X X X X X X, - - - X, - - X X X X X X, - - - - X X X X X, - - - X X X X, - - X X X, - X X X, - - X X, - X X X, - X, - X, - X, - - - X, - X, - - X X X X, X X, X X, X X, X, X X, X X, X, X X X X, X X, X X, X X, X, X X, X X, X

X, C-6

Means the parameter is set to a character. Means the parameter is disabled.

Page 486

NF

C

BC Configuration and Full ASCII Charts

POL and SEL Combinations for Multi-Drop Protocol To configure User-Defined Multi-Drop protocol, you use POL and SEL character combinations. You must assign the POL and SEL protocol characters in a predetermined combination. The following table lists the device address and the corresponding POL and SEL combinations. When you configure Multi-Drop protocol, you select the device address and then the reader automatically sets the predefined POL and SEL combination listed for that address. Device Address

POL

SEL

A

FS

GS

B

RS

C

Device Address

POL

SEL

Q

<

=

US

R

>

?

SP

!

S

@

A

D

"

#

T

B

C

E

$

%

U

D

E

F

&

‘

V

F

G

G

(

)

W

H

I

H

*

+

X

J

K

I

‘

-

Y

L

M

J

.

/

Z

N

O

K

0

1

0

P

Q

L

2

3

1

R

S

M

4

5

2

T

U

N

6

7

3

V

W

O

8

9

4

X

Y

P

:

;

5

Z

[

C-7

Page 487

JANUS 2020 Hand-Held Computer User’s Manual (4MB) NFBC

Key Codes Use the key codes to redefine scanned characters to a keystroke equivalent. Find each key’s four-digit hexadecimal value in the Key Code table. You can use the key code in an application or to change the reader’s key code look-up table. For help, see the “Key Code Look-Up Table” in Chapter 12. Key

Lists each key on a standard 102 key PC keyboard.

Normal Shift

Lists the key code value for the Shift key plus the key.

Control Alt

Lists the key code value for each key.

Lists the key code for the Control key plus the key.

Lists the key code for the Alt key plus the key.

<

For example, the key code for code for is 1E00.

O

(an uppercase letter A) is 1E41. The key

Key Code Table Key

Normal

Shift

Control

Alt

F1

3B00

5400

5E00

6800

F6

4000

5900

6300

6D00

F11

8500

8700

8900

8B00

F2

3C00

5500

5F00

6900

F7

4100

5A00

6400

6E00

F12

8600

8800

8A00

8C00

F3

3D00

5600

6000

6A00

F8

4200

5B00

6500

6F00, - - - F4

3E00

5700

6100

6B00

F9

4300

5C00

6600

7000

Scroll Lock

C-8

Page 488

NF

BC Configuration and Full ASCII Charts

C

Key Code Table (continued) Key

Normal

Shift

Control

Alt, - 0000, F5

3F00

5800

6200

6C00

F10

4400

5D00

6700

7100

Print Screen, - 7200, A

1E61

1E41

1E01

1E00

B

3062

3042

3002

3000

C

2E63

2E43

2E03

2E00

D

2064

2044

2004

2000

E

1265

1245

1205

1200

F

2166

2146

2106

2100

G

2267

2247

2207

2200

~ `

2960

297E, 2900

H

2368

2348

2308

2300, –

0C2D

0C5F

OC1F

8200

I

1769

1749

1709

1700

+ =

0D3D

0D2B, 8300

J

246A

244A

240A

2400

{[

1A5B

1A7B

1A1B

1A00

K

256B

254B

250B

2500

}]

1B5D

1B7D

1B1D

1B00

Pause

C-9

Page 489

JANUS 2020 Hand-Held Computer User’s Manual (4MB) NFBC

Key Code Table (continued) Key

Normal

Shift

Control

Alt

L

266C

264C

260C

2600

:;

273B

273A, 2700

M

326D

324D

320D

3200

N

316E

314E

310E

3100

O

186F

184F

180F

1800

P

1970

1950

1910

1900

Q

1071

1051

1011

1000

R

1372

1352

1312

1300

S

1F73

1F53

1F13

1F00

2827

2822, 2800

T

1474

1454

1414

1400

|\

2B5C

2B7C

2B1C

2B00

U

1675

1655

1615

1600

V

2F76

2F56

2F16

2F00

<,

332C

333C, 3300

W

1177

1157

1117

1100

>.

342E

343E, 3400

X

2D78

2D58

2D18

2D00

352F

353F, 3500

1579

1559

1519

1500

"

?

Y

C-10

'

/

Page 490

NF

BC Configuration and Full ASCII Charts

C

Key Code Table (continued) Key

Normal

Shift

Control

Alt

Z

2C7A

2C5A

2C1A

2C00

(right)

Ctrl, - - - (left)

Ctrl, - - - (right)

Alt, - - - (left)

Alt, - - - (right)

Shift, - - - (left)

Shift, - - - - - - - 0837

0826, 7E00

47E0

47E0

77E0

9700

Home

7

4700

4737

7700

See Note

*

8

0938

092A, 7F00

+

4E2B

4E2B

9000

4E00

8

4800

4838

8D00

See Note

(

0A39

0A28, 8000

49E0

49E0

84E0

9900

4900

4939

8400

See Note

0E08

0E08

0E7F

0E00

Esc

011B

011B

011B

0100

$

0534

0524, 7B00

Caps Lock

&

7

Home

9

PgUp

9

PgUp

(backspace)