The text of a manual · part 34 of 57
JANUS 2020 Hand-Held Computer (4MB) User's Manual, pages 331 to 340
Pages 331 to 340 of 565
The original document is the PDF (2.7 MB). This is its text as extracted, unedited; tables and drawings read best in the PDF, and each page heading opens it at that page.
For the Intermec J2020, Intermec JG2020 and Intermec JR2020
Page 331
JANUS 2020 Hand-Held Computer User’s Manual (4MB) NFBC
Backlight On and Off Purpose:
Turns the backlight on to easily view the reader display in dimly lit environments.
From Host:
Not supported
Keypad:
1. Press 2. Press 3. Press
A< @ ? -
, and then release both keys to enter Control mode.
to turn the backlight on or off.
to exit Control mode.
IRL Command:
Z"%.1"
Scan:
Backlight On
*%.1* *%.1*
Purpose:
Turns the backlight off.
From Host:
Not supported
Keypad:
1. Press 2. Press 3. Press
A< @ ?
IRL Command:
Z"%.0"
Scan:
Backlight Off
-
, and then release both keys to enter Control mode.
to turn the backlight on or off.
to exit Control mode.
*%.0* *%.0*
Note: You can use the command %. to toggle the backlight on and off.
11-4
Page 332
NF
BC Reader Command Reference
11
Backspace Purpose:
Deletes the last character from the current data record. If there is no data in the buffer, the reader sounds three low beeps.
From Host:
Not supported
Keypad:
= or
IRL Command:
Not supported
Scan:
Backspace
*-+* *-+*
Change Configuration Purpose:
This command must precede any configuration command parameter. If you enter a valid string, the reader configuration parameters are modified and the reader sounds a high beep. For help on the configuration parameters, see Chapter 12, “Configuration Command Reference.” Note: You no longer need to use the Exit Configuration command ($-) after a Change Configuration command, but it is allowed for backward compatibility.
From Host:
$+command
Keypad:
Not supported
IRL Command:
Z"$+command"
Scan:
Change Configuration
*$+* *$+*
Enter a configuration command or scan a bar code label containing a configuration command. For example, enter the command BV0 to turn the beep volume off.
11-5
Page 333
JANUS 2020 Hand-Held Computer User’s Manual (4MB) NFBC
Clear Purpose:
Deletes the entire data record you are accumulating.
From Host:
Not supported
Keypad:
Not supported
IRL Command:
Not supported
Scan:
Clear
*--* *- -*
Command Override Purpose:
Causes the character that follows it to be treated as data. Command override allows you to use control characters in preambles, postambles, data strings, and configuration command strings.
From Host:
<DLE>
Keypad:
>/
The key sequence ^P (Ctrl P) is also the ASCII Data Link Exception character (DLE). ^P causes the character that follows it to be received as data, even if it is a protocol character. To interpret a Command Override command from the host, the command must be preceded by DLE. For example, when ^P^P^M is sent from the host, it is interpreted as ^P^M, where ^P is acknowledged allowing the next command (^M) to be interpreted as data and passed on to the application. When ^P^M is sent from the host, it is interpreted as ^M, the display is not affected and the Carriage Return command is executed. IRL Command:
Z"^P"
Scan:
Command Override
*$P* *<DLE>*
11-6
Page 334
NF
BC Reader Command Reference
11
The JANUS 2020 reader uses Ctrl-P as the Command Override command; however, the DOS printer redirection command (Ctrl-P) is also supported on the reader. This dual purpose may cause some conflicts. If you have Reader Services loaded and scan the bar code label <DLE>, the first scan is interpreted as a reader command. The next <DLE> entered causes a Ctrl-P to be entered into the expanded key buffer. DOS takes this Ctrl-P and enables printer redirection. If no printer is connected, all subsequent entries cause an error and the next message is displayed: Write fault error writing device PRN Abort, Retry?
DOS shuts off the printer echo for the duration of the error, which allows it to display the error. As long as the printer echo has been requested (by entering a Ctrl-P), DOS turns the printer echo back on after the critical error is corrected. To exit the critical error, press to turn off the console echo to the printer, and then press to abort.
>/
Enter Purpose:
Enters the current data record or completes the entry of a command. If no data exists, a null string is entered.
From Host:
Not supported
Keypad:
@
IRL Command:
Not supported
Scan:
Enter
** **
11-7
Page 335
JANUS 2020 Hand-Held Computer User’s Manual (4MB) NFBC
Enter and Exit Accumulate Mode Accumulate mode is used to accumulate all scanned data in the reader’s data buffer. When you exit Accumulate mode, the accumulated data is “entered” as a data record. The buffer is cleared by one of these commands: •
Exit accumulate command
•
Enter command
•
Clear command
•
Any type of reset
Up to 250 characters can be held in the buffer. If the data record count exceeds 250 characters, the last bar code read is rejected and the reader sounds an error beep. Purpose:
Enters Accumulate mode. If you press any keys when using the Enter Accumulate command, the keystrokes are accumulated as data.
From Host:
Not supported
Keypad:
Not supported
IRL Command:
Not supported
Scan:
Enter Accumulate Mode
*+/* *+/*
Purpose:
Exits Accumulate mode and transmits the current data record. If no data has been accumulated, an empty data record is entered.
From Host:
Not supported
Keypad:
Not supported
IRL Command:
Not supported
Scan:
Exit Accumulate Mode
*-/* *-/*
11-8
Page 336
NF
BC Reader Command Reference
11
IRL File, Clear Purpose:
Deletes one or all of the IRL data files that have default filenames: {IRL-0}.IRD, and {IRL-A}.IRD through {IRL-Z}.IRD. For help, see “Clearing IRL Data Files” in Chapter 7. Note: You can use this command only from the IRL Desktop.
From Host:
.$filename where filename is 0 or any character from A to Z. If you do not include a filename, all IRL data files (0, A to Z) are deleted. Caution When the clear file command is sent from the host without data, all data is cleared and all files are deleted. Conseil Lorsque la commande d'effacement de fichier (clear file) est envoyée de l'hôte sans préciser les données à effacer, toutes les données sont effacées et tous les fichiers sont supprimés.
Keypad:
In the IRL Desktop, choose File and then choose Clear Data.
IRL Command:
Not supported
Scan:
Scan one of these bar codes: Clear All IRL Data Files
*.$* *.$*
Clear {IRL-0}.IRD
*.$0*
*.$0*
Note: You can create bar code labels to delete {IRL-A}.IRD through {IRL-Z}.IRD. If you choose to clear all data files, a message explains that the default data files will be deleted and shows the directory where the files are located. Choose OK to delete the data files. If you clear one data file, IRL deletes the file without displaying a message or prompt.
11-9
Page 337
JANUS 2020 Hand-Held Computer User’s Manual (4MB) NFBC
IRL File, Receive Purpose:
Accepts a file from the host and saves it under the specified filename. If the filename is not included, the reader displays the Receive screen, which lets you select a COM port and filename. For help, see “Receiving IRL Files” in Chapter 7. Note: You can use this command only from the IRL Desktop.
From Host:
.%filename
Keypad:
In the IRL Desktop, choose File and then choose Receive.
IRL Command:
Not supported
Scan:
Receive IRL File
*.%* *.%*
IRL File, Transmit Purpose:
Sends the specified file to the host. If the filename is not included, the reader displays the Transmit screen, which lists all .IRL and .IRD files in the current directory. For help, see “Transmitting IRL Files” in Chapter 7. Note: You can use this command only from the IRL Desktop.
From Host:
%%filename
Keypad:
In the IRL Desktop, choose File and then choose Transmit.
IRL Command:
Not supported
Scan:
Transmit IRL File
*%%* *%%*
11-10
Page 338
NF
BC Reader Command Reference
11
IRL Program, Download Purpose:
Downloads the program you specify from the host computer to the reader. For help, see “Downloading an IRL Program” in Chapter 7. The command renames the program to {IRL-1}.IRL and copies it to the directory specified by the IM_IRLPROG path in your AUTOEXEC.BAT file. If the program path is on a nonwritable drive, the program is copied to the data path. If there is an {IRL-1}.IRL program already in the directory, it is overwritten. If the command detects an error, an error message appears and control returns to the IRL Desktop. To download an IRL program, send a Start of Program (SOP) character followed by the program to be downloaded from the host computer. You can set the SOP character in the reader’s configuration. The default is <SI>. For help, see “IRL SOP” in Chapter 12. You can also use PC-IRL, Collect, DCM, DFM, or Interscan to download IRL programs. For help, see the product’s manual. Note: You can use this command only from the IRL Desktop.
From Host:
<SOP>
Keypad:
Not supported
IRL Command:
Not supported
Scan:
Not supported
IRL Program, Exit Purpose:
Exits the IRL program that is running. For help, see “Exiting an IRL Program” in Chapter 7.
From Host:
/$
Keypad:
Press the application break sequence. For help, see “Breaking Out of an Application” in Chapter 9.
IRL Command:
Not supported
Scan:
Exit IRL Program
*/$* */$*
11-11
Page 339
JANUS 2020 Hand-Held Computer User’s Manual (4MB) NFBC
IRL Program, Resume Purpose:
Starts running the program named in the {LATEST}.RSM file exactly where the program left off when it was halted or exited. For help, see “Resuming IRL Programs” in Chapter 7. Note: You can use this command only from the IRL Desktop.
From Host:
$.
Keypad:
In the IRL Desktop, choose File and then choose Resume.
IRL Command:
Not supported
Scan:
Resume IRL Program
*$.* *$.*
IRL Program, Run Purpose:
Runs the default IRL program {IRL-1}.IRL. For help, see “Running an IRL Program” in Chapter 7. Note: You can use this command only from the IRL Desktop.
From Host:
//
Keypad:
In the IRL Desktop, choose File and then choose Run.
IRL Command:
Not supported
Scan:
Run IRL Program
*//* *//*
11-12
Page 340
NF
BC Reader Command Reference
11
Laser On and Off The Laser On and Off commands are the same as pulling and releasing the scanner trigger. After a Laser On command, the scanner operates differently depending on the scanner mode and scanner trigger configuration settings: •
If you configure the reader to use One-Shot Scanner mode and level triggering, the scanner automatically turns off after a good read of a bar code label, or after the scanner timeout period elapses.
•
If you configure the reader to use Automatic Scanner mode and level triggering, the scanner remains on after a good read of a bar code label. You use the Scanner Timeout command or the Laser Off command to turn off the scanner.
Note: Intermec does not recommend that you use a Laser On or Off command with the Scanner Trigger command set to edge triggering. Purpose:
The Laser On command is the same as pulling the scanner trigger.
From Host:
/.
Keypad:
Not supported
IRL Command:
Z"/."
Scan:
Not supported
Purpose:
The Laser Off command is the same as releasing the scanner trigger. Its effect depends on the scanner and trigger mode configuration settings as described above.
From Host:
/%
Keypad:
Not supported
IRL Command:
Z"/%"
Scan:
Not supported
11-13