Running IRL Programs (continued) Problem
Solution
When you try to start the IRL Desktop, the reader displays an error message indicating that there is not enough memory available to run the Configuration Manager.
If the Configuration Manager TSR is unloaded when you start the IRL Desktop, the reader automatically loads the TSR for you. If there is not enough conventional memory available for the Configuration Manager TSR, the reader displays an error message. Make sure at least 50K of memory is available.
The reader is locked up in an IRL program.
Perform the application break sequence, as described in “Breaking Out of an Application” in Chapter 9.
You are having problems trying to download an IRL program.
Make sure you have performed all these steps: • You configured the communications protocol correctly on the reader and host. For help, see “Configuring the Communications Protocols” in Chapter 6. • You activated the communications protocol. For help, see “Activating One Communications Protocol” in Chapter 6. • You loaded the protocol handler. For help, see “Loading and Unloading a Protocol Handler” in Chapter 6. • You are in the IRL Desktop, at the main menu, with no commands selected. You have trouble running an IRL program with Interlnk.
10-18
You cannot run an IRL program over an Interlnk connection.
Page 312
nuggethelCODE39Troubleshooting
10
Using PC Cards This table lists problems that may occur when you use PC cards in the JANUS reader. For help, see Chapter 4, “Using PC Cards in the Reader.” Problem
Solution
You are trying to access the reader’s PC card drive and you see the message, “Invalid media type reading drive X. Abort, Retry, Fail?”
Press to abort. The reader cannot read the PC card in the drive. Use the CARDINFO utility to verify the type of card you are using (ATA, flash, I/O, or SRAM).
You are trying to access the reader’s PC card drive and you see the message, “Not ready reading drive X. Abort, Retry, Fail?”
Press to try again. If you see the message again, press to abort. The reader cannot read the PC card in the drive. Use the CARDINFO utility to verify the type of card you are using (ATA, flash, I/O, or SRAM).
Check the reader’s CONFIG.SYS file. Make sure you have the correct drivers installed for the type of card you are using. Format the PC card.
1
Check the reader’s CONFIG.SYS file. Make sure you have the correct drivers installed for the type of card you are using. Format the PC card. You may also see this message if you are using the Substitute command and you do not have a PC card in each PC card drive. Insert a PC card in each drive and try using the Substitute command again. You try to access the reader’s PC card drive and you see the message, “Bad command or file.”
Check the command you entered and make sure it is a valid command. Try entering the command again.
You access the PC card in the PC card drive and the reader locks up frequently.
The PC card may not be formatted correctly. If you formatted the PC card on your PC or host computer, try formatting the card in the reader’s PC card drive. You can also use the CARDINFO utility to verify the current format and status of the card.
You try to load APM_4M.EXE or IPM_4M.EXE and you see the message, “CS PM already loaded.”
You cannot load APM_4M and IPM_4M at the same time. If you see this message, one of the utilities is already loaded. Load APM_4M only for I/O cards; otherwise use IPM_4M. Check the AUTOEXEC.BAT file to see which utility is loaded. If you are loading the wrong one, edit the AUTOEXEC.BAT file or load the utility from the DOS prompt. For help, see “Drivers in AUTOEXEC.BAT” in Chapter 4.
10-19
Page 313
JANUS 2020 Hand-Held Computer User’s Manual (4MB)NF
BC
Using PC Cards (continued) Problem
Solution
You hear the reader sound a single low tone beep when you insert a PC card in the PC card drive.
The reader cannot read the card in the PC card drive. You need to format the card. For help, see “Configuring, Formatting, and Using PC Cards” in Chapter 4. If you followed all the instructions to format a flash PC card and the reader still does not recognize the card, you may need to install two other flash card drivers. You need to install the MTAA.EXE and MTAB.EXE drivers to use AMD Type A or B flash cards. Copy the two drivers from the Application companion disk 3 to drive C on the reader (using Auto-Loader or MakeDisk and PutDisk). Edit the CONFIG.SYS file and add these lines after the line that installs the MTI2P.EXE driver: device=c:\mtaa.exe device=c:\mtab.exe After you place the revised CONFIG.SYS file on the reader’s drive C, boot the reader and try to format the flash card again.
You delete files from a 512K flash card and it does not appear that there is any additional space available on the card.
If you are using a 512K flash card with an MS-Flash file format, the card is formatted as a WORM (Write Once Read Many) drive. A 512K flash card does not have room for more than one separately erasable block of memory. You can delete individual files using the DOS delete command, but the memory the files were using is not available to be used again. To reclaim the memory from deleted files, you need to erase the entire card and then reformat the card. Note: Intermec recommends using flash cards that store 1MB or more of data.
You try to format a flash PC card with the MCFORMAT utility and you see the message, “You must erase X: before creating a new partition.”
If a flash card has been formatted before, you must erase the card before you can format it. Use the MCFORMAT utility and select option from the MCFORMAT main menu to erase a flash card.
If you erase the flash card and still see this message when you try to format the card or the card will not format, check CONFIG.SYS. Make sure the flash card drivers are installed. Once the flash card drivers are active in CONFIG.SYS, try erasing the flash card. Then format the card.
10-20
Page 314
nuggethelCODE39Troubleshooting
10
Using PC Cards (continued) Problem
Solution
After you load your Novell network software, you use a network PC card and run an application that does not work properly after making a system call.
Your Novell network software may have modified the COMSPEC environment variable to add a drive specifier to the path. However, DOS needs COMSPEC to find the COMMAND.COM file, which must be loaded for DOS to execute system commands. The reader uses ROM DOS, which expects COMSPEC to be set to: comspec=command To eliminate this problem, run the INITENV utility before you log onto a NetWare server. INITENV.EXE is on the reader’s drive C and Application companion disk 3. Create a login batch file similar to this one: @echo off c:\initenv e:\login %1 %2 set comspec=command Use the new login file instead of your Novell login file when you log the reader onto the server. If you do not run INITENV.EXE before logging in, your DOS environment table will be corrupted and cause your JANUS application to fail. You can set COMSPEC correctly to fix part of the problem, but you must boot the reader to clear embedded garbage characters from the environment table.
@
To check COMSPEC, type set and press . All environment variables are displayed. If COMSPEC was set to anything other than COMMAND, it has been changed by the login process.
10-21
Page 315
JANUS 2020 Hand-Held Computer User’s Manual (4MB)NF
BC
Using DOS Commands and Applications This table lists problems that may occur when you run DOS-based applications on the reader. Problem
Solution
The reader displays a “Write Fault Error Writing Device PRN” message.
A <DLE> or Ctrl-P was entered into the reader. There may be a conflict because <DLE> is both the Intermec command override command and the DOS printer redirection command. Press to turn off console echo to the printer and then press to abort. For help, see “Command Override” in Chapter 11.
The reader is locked up in an application.
Perform the application break sequence, as described in “Breaking Out of an Application” in Chapter 9.
There is not enough memory to load a program.
You need to free conventional memory. For help, see “Making More Memory Available on the Reader” in Chapter 3.
The reader locks up when running AutoLoader and you cannot reboot the reader.
Use the Boot Loader menu to reload the system flash memory. For help, see “Loading Flash Memory” in Chapter 9.
You have trouble running an IRL program over an Interlnk connection.
You cannot run an IRL program over an Interlnk connection.
You do not have MS-DOS Programs companion disk 2 and need to use Interlnk.
If you do not have companion disk 2, which contains the Interlnk files, you can install Interlnk to the host from the reader.
>/
Connect the reader and host computer with a 7-wire RS-232 cable when installing Interlnk. The MODE command must be available on the host where you are installing Interlnk. Type this command on the reader: intersvr /rcopy The command copies the Interlnk files to the host computer. The host computer locks up after you type this command on the reader:
When the Interlnk files are downloaded to the host computer, the host computer may lock up. Reboot the host computer.
intersvr /rcopy The reader locks up when you are using Interlnk and try to get a directory listing (DIR) on one of the reader’s ROM drives.
10-22
Edit the host computer’s AUTOEXEC.BAT or CONFIG.SYS file and remove or remark out Windows SMARTDRV.EXE.
Page 316
nuggethelCODE39Troubleshooting
10
Using DOS Commands and Applications (continued) Problem
Solution
The reader locks up just after the DOS boot banner message appears when you finish updating drive C with Auto-Loader.
Press Alt-F4 on the host computer and then warm boot the reader. A lockup occurs when both these conditions are true: • An active Intersvr connection to the JANUS reader exists when the reader reboots. The reader’s default CONFIG.SYS file installs Interlnk automatically when the reader is connected to COM1 of the host computer and the host is running Intersvr. • The reader’s CONFIG.SYS and AUTOEXEC.BAT install a combination of device drivers, DOS options, TSRs, and applications that absorb the majority of available conventional memory. When both conditions exist, there is not enough space for your software configuration to coexist with the Interlnk device driver. The reader attempts to allocate memory that is not available, and a lockup may occur. To prevent the lockup, press Alt-F4 on the host computer or break the serial connection between the reader and host computer before the reader reaches the DOS initialization step of the warm boot. When you exit Intersvr on the host computer or break the serial connection, the Interlnk device driver will not detect INTERSVR.EXE, and Interlnk will not be loaded into the reader’s memory.
You cannot access a drive while using Interlnk.
Interlnk does not redirect network drives, CD-ROM drives, or any other device that uses a redirection interface. These commands do not work with Interlnk: CHKDSK DISKCOMP DISKCOPY FORMAT
The reader does not boot after you modified the CONFIG.SYS file.
MIRROR SYS UNDELETE UNFORMAT
Correct the error in CONFIG.SYS. Use Auto-Loader, BFT, or MakeDisk and PutDisk to load the new CONFIG.SYS onto the reader. Boot the reader. The reader should boot with the corrected CONFIG.SYS file.
10-23
Page 317
JANUS 2020 Hand-Held Computer User’s Manual (4MB)NF
BC
Using DOS Commands and Applications (continued)
1
Problem
Solution
You see this message when you use Interlnk/Intersrv to copy files between the reader and the host computer:
Press to Retry and continue copying the files. You may have a problem copying files if you use the DOS version (utilities from your PC) of INTERLNK.EXE and INTERSVR.EXE on the JANUS reader. Intermec modified the INTERLNK.EXE and INTERSVR.EXE utilities to work with the JANUS reader. The Intermec version of these utilities is provided on the reader’s Drive D and on the MS-DOS Programs Companion Disk 2. Use the INTERLNK.EXE and INTERSVR.EXE utilities provided with your reader to transfer and copy files.
“Not ready writing drive X. Abort, Retry, Fail?”
If your files were not copied correctly, try the procedure again using the INTERLNK.EXE and INTERSVR.EXE utilities provided with your reader.
10-24
Page 318
nuggethelCODE39Troubleshooting
10
Using MakeDisk This table lists messages that you may see when you use MakeDisk to create a new image file for drives C or D. Message
Explanation/Solution
A source path has been specified that contains no files.
You cannot attempt to create an image file from a source directory that contains no files. MakeDisk will not let you create an empty drive image.
An invalid path and/or file name has been specified for the image file.
MakeDisk was unable to create the image file based on the “/o=[path\filename]” argument. This error can be caused by either an invalid path name (for example, a path that doesn’t exist or a “not ready” drive), or a path\filename that contains characters that DOS does not recognize as valid characters for filenames.
An invalid path name has been specified.
MakeDisk could not find the source directory path you specified on the command line. Please specify a valid subdirectory for the “/s=[path]” argument.
•
Corrupt BPB in suffix: Unable to create a drive image.
If either of these messages persist after further attempts, it may indicate a corrupted MAKEDISK.EXE file. Get a fresh copy of MAKEDISK.EXE from the Boot Utilities companion disk.
•
Corrupt suffix: Unable to create a drive image.
Drive full: Unable to write a complete image file to the output drive. Remove some files or specify a different output path and file name.
The drive where the image file is being written has insufficient free space available to contain the entire image file.
ERROR, unknown or incomplete command, or too many characters: [bad command line argument shown here].
You have entered a command line argument that MakeDisk does not recognize (as shown in the error message). Run MakeDisk again with the command line argument corrected.
Insufficient memory, unable to create a complete image file. Try again after removing device drivers, TSRs, or other applications that are occupying conventional memory.
There is not enough conventional DOS memory available on the computer running MakeDisk to complete the MakeDisk process. You may need to unload (terminate) some applications, device drivers, or TSRs in order to free the needed memory. Another approach is to reduce the number of nested subdirectories in the longest directory chain below your source directory.
Invalid drive letter specified. Please specify either drive C or D only.
MakeDisk will only create image files for drives C and D on your 4MB JANUS device.
10-25
Page 319
JANUS 2020 Hand-Held Computer User’s Manual (4MB)NF
BC
Using MakeDisk (continued) Message
Explanation/Solution
Makedisk was unable to complete the drive image. Try again.
You may receive this message for several types of general faults such as: •
One or more of the files in the source directory could not be accessed. This could indicate a corrupt file or a bad disk.
•
A network error occurred when DOS attempted to retrieve a remote file.
•
DOS was unable to read the source directory for any number of reasons.
Please specify a source path where your drive image can get its files from.
Enter a valid subdirectory name where your source files reside that will be used to create the drive image. (This is the /s=[path] argument).
The root directory can only contain [n] files; your source files exceed this count. Place some of your root files in a subdirectory as an alternative.
Your source directory (first level) contains more than the maximum number of files and/or subdirectories permitted for the target drive’s root directory. One approach to solve this is to place some of the first-level files in a subdirectory below your source directory.
The system has too many files open; unable to create a drive image. Increase the 'FILES=' setting in your CONFIG.SYS file or terminate other applications that may be running.
MakeDisk needs to open several files during the image file creation process, but is unable to do so. You may need to terminate other applications or close some files in order to complete the MakeDisk process.
Your source files would create a [n] byte image file which is [n] bytes in excess of drive [C: or D:] capacity.
The total size of the files and subdirectories in your source directory, including the overhead space required to emulate a DOS compatible drive, exceeds the storage capacity of the JANUS drive you have targeted.
10-26
Page 320
nuggethelCODE39Troubleshooting
10
Using PutDisk This table lists messages that you may see when you use PutDisk to load a new image file to drives C or D. Message
Explanation/Solution
Attempt to allocate memory failed, unable to proceed.
This indicates that there is not enough conventional DOS memory available for PutDisk to complete the flash update process. You may need to unload (terminate) some applications, device drivers, or TSR programs to free the needed memory.
Attempted to upgrade a ROM drive, unable to proceed.
PutDisk has determined that the target JANUS drive is comprised of ROM (read-only memory, which cannot be written to by PutDisk) instead of flash memory. Other kinds of system faults can lead PutDisk to make this determination in error, such as a flash programming voltage fault or address decoding problems.
Attempted upgrade in a RAM region, unable to proceed.
PutDisk has determined that the target JANUS drive is comprised of RAM (random access memory, which cannot support a non-volatile drive) instead of flash memory. Other kinds of system faults can lead PutDisk to make this determination in error, such as faulty flash memory or address decoding problems. You may need technical support to solve this type of error.
Cannot upgrade an unsupported drive.
Attempts to update a JANUS drive other than C or D are unsupported. Restart PutDisk, and specify the drive /d=[drvletter] as either C or D.
•
Fault has occurred during attempt to erase flash memory.
•
Fault has occurred during attempt to write flash memory.
If either of these messages persist after retrying PutDisk with a fresh battery or charging source, it may indicate a flash memory hardware failure on the JANUS device.
Image checksum failed comparison with checksum of received data.
This may indicate that the flash memory update was incomplete. You will need to restart PutDisk using the same image file.
Image file error: Drive image file is larger than the drive's BPB capacity.
The size of the drive image file is larger than is declared valid by the formatting portion of the image file. You will have to reconstruct the drive image file by using the MakeDisk utility.
Image file error: Drive image file is larger than the flash media capacity.
The size of the image file is larger than the targeted drive’s flash memory on the JANUS device. You must reduce the total file content (total size) of the drive image file by rebuilding it with the MakeDisk utility using fewer or smaller files.
10-27