Page 111

JANUS 2020 Hand-Held Computer User’s Manual (4MB) NFBC where: path is the drive and directory of the file or files to include in the image file. If you do not include a path, the current directory is used.

filename is the name of the file or files to include in the image file.

You can include multiple path\filename and path\*.* parameters in the command. The path\*.* parameter loads all the files in a directory. For example: loadnew c:\janus\data.txt c:\atadrv\*.* c:\data\*.*

6. The image file is saved as NEWDRV_C\IMAGE\DRIVEC.IMG on the host computer. The next time you execute the MAKENEW command, this image file will be overwritten. To protect the image file, you can rename it. To rename the image file When you execute a LOAD or MAKE command, Auto-Loader saves a copy of the drive C image file as NEWDRV_C\IMAGE\DRIVEC.IMG. You can copy that file to multiple readers. Auto-Loader overwrites DRIVEC.IMG each time you create a new image file. If you rename DRIVEC.IMG, it will not be overwritten. You can also create multiple image files and rename each with a unique name. For example, you can create an image file for each type of PC card you use in the reader. Each image file contains a CONFIG.SYS that loads the drivers for the PC card. When you need to switch PC cards in the reader, you can load the appropriate image file to the reader: •

NEWDRV_C\IMAGE\C-ATA.IMG

•

NEWDRV_C\IMAGE\C-FLASH.IMG

To copy the image file to more than one reader Note: All the files on each reader’s drive C will be overwritten. 1. Connect the reader to the host computer through a communications dock or optical link adapter. If you use the communications dock, you must connect the dock to the host computer with a 3-wire (2, 3, and 7) cable for Interlnk to operate properly. 2. Connect the power supply to the communications dock or the optical link adapter.

3-22

Page 112

NF

BC Learning About the Software

3

3. Type the LOADXIMG or LOADIMG command: •

If the image file has the NEWDRV_C\IMAGE\DRIVEC.IMG default name, type this command on the host computer: loadximg

•

If the image file has any other name, type this command on the host computer: loadimg path\filename where: path is the drive and directory of the image file to load.

filename is the name of the image file to load.

For example, to load the FLASH\C-ATA.IMG image file, type this command on the host computer: loadimg c:\flash\c-ata.img

4. Auto-Loader runs Intersvr on the host computer. When you see the Interlnk Server Status screen on the host computer, press to warm boot the reader and load Interlnk into memory. Auto-Loader begins updating drive C. 5. When the update is complete, the reader reboots automatically. 6. To load the image file on another reader, disconnect the reader from the host computer, connect another reader to the host computer, and repeat Steps 3 through 5.

Note: Interlnk is still loaded in memory on the reader you disconnected from the host computer. You can press to warm boot the reader and remove Interlnk from memory. 7. When you finish updating your JANUS readers, you can exit Intersvr on the host computer by pressing Alt-F4. You will see this message: Drive C:

Installation process completed.

3-23

Page 113

JANUS 2020 Hand-Held Computer User’s Manual (4MB) NFBC

Using MakeDisk and PutDisk to Change Drives C or D You can use the MakeDisk and PutDisk utilities to perform these tasks on your 4MB JANUS device: •

Adding or editing files on drives C or D.

•

Replacing some files on drives C or D.

•

Replacing all of the files on drives C or D.

•

Deleting files from drives C or D.

Follow these steps, which the next sections describe in detail: 1. Create a working directory and fill it with files for drive C or D. 2. Create the new image file with MakeDisk. 3. Load the new image file onto the JANUS device with PutDisk. Note: Due to its large size, MakeDisk is not loaded on drive D. You must copy the self-expanding executable C_MAKE.EXE from the Boot Utilities companion disk to a drive on the host PC and run C_MAKE.EXE. After running C_MAKE.EXE, delete all of the extracted files except for MAKEDISK.EXE. Caution Do not run any Intermec-provided JANUS application programs (such as IC.EXE) on your PC. Also, do not run any .EXE programs that use Intermec interrupt extensions or libraries on your PC. These programs will lock up your PC and may corrupt the PC BIOS. Conseil N'exécutez pas sur votre PC de programmes d'application JANUS fournis par Intermec (tels que IC.EXE). N'exécutez pas non plus sur votre PC de programmes .EXE qui utilisent des bibiothèques ou des extensions d'interruption car ces programmes bloqueront votre PC et pourraient corrompre le BIOS du PC.

Deciding Where to Run MakeDisk You can run MakeDisk: •

3-24 on the RAM drive. If you want to make images larger than 256K on the RAM drive, you need to change your CONFIG.SYS file to enlarge the drive. Use the following to estimate the amount of space needed to create a RAM drive for running MakeDisk.

Page 114

NF

BC Learning About the Software

3

Note: On drive C you need to allocate space for your files, plus 15K, plus 512 bytes overhead per file, and 135K for the MS-DOS system files. Note: On drive D you can omit the 135K for the MS-DOS system files. • on a PC card inserted into the JANUS device.

• on a host computer with or without Interlnk. With Interlnk You can use Interlnk to copy files from drives C or D to the host’s working directory and then copy MAKEDISK.EXE to a working directory on the host computer. Without Interlnk You can run MakeDisk on the host computer without Interlnk if you copy MAKEDISK.EXE to a working directory on the host computer. You can also use the DOS COPY commands to copy additional files from the companion disks instead of from drives C or D.

Creating and Filling the Working Source Directory 1. Create a working source directory where you will store the files you want on drives C or D. Since the use of subdirectories is fully supported by MakeDisk, you can create and populate subdirectories in the working source directory. 2. Create or copy files to the working directory. You can create or copy a maximum of 125 files to the drive C root directory or 128 files to drive D root directory. You can create or copy an infinite number of files to subdirectories below the root directory, provided they can fit in the allocated drive space. •

If you are adding new files to drives C or D, copy all files currently on drives C or D as well as the new files to the working directory and its subdirectories.

•

If you are changing or replacing some of the existing files on drives C or D, copy all files currently on drives C or D to the working directory and its subdirectories. Edit the files you want to change or replace.

•

If you are replacing all files on drives C or D, copy the files you want on drives C or D to the working directory and its subdirectories.

•

If you are deleting files from drives C or D, copy all files currently on drives C or D to the working directory and its subdirectories. Delete the files you want to remove from drives C or D.

You can use the DOS COPY command to copy files from the companion disks, or you can use Interlnk to copy files from the JANUS drives C or D.

3-25

Page 115

JANUS 2020 Hand-Held Computer User’s Manual (4MB) NFBC

Creating the New Image File Create the image file by typing the command: makedisk /s=[path] {/o=[output file] /d=[drvletter]} where: path specifies the directory that contains the files for the image file. This directory is called the source directory. The path parameter is required. You may choose to include the drive letter if the source directory resides on another drive. For example, you could enter A:\JANUS\IMAGE as the path. If you do not specify the path correctly, the command fails.

output file specifies the full path and name of the image file to create. If you do not include this parameter, the image file is called DRIVE_C.IMG (DRIVE_D.IMG if you specified /d=d) and is placed in the current working directory. The output file parameter is optional.

drvletter specifies the target JANUS drive, either C or D. The default is drive C. The drvletter parameter is optional.

All files in the source directory are placed into the image file, including hidden and read-only files. If subdirectories exist, they are also incorporated in the image file. Note: If you have problems running MakeDisk or PutDisk, see Chapter 10, “Troubleshooting.”

Loading the New Image File Note: When you run PutDisk, all files on drives C or D are overwritten. Be sure to back up any files you want to keep before you continue. 1. Connect the JANUS device to the host computer. Note: If you use a communications dock and plan to use Interlnk during this procedure (as described in Step 3), you must connect the dock to the host computer with a 3-wire (2, 3, and 7) cable for Interlnk to operate properly.

3-26

Page 116

NF

BC Learning About the Software

3

2. Connect a power supply to the communications dock or optical link adapter. Note: For JANUS 2010 and 2020 devices only. This step is recommended, but is not required. Caution JANUS 2010 and 2020 devices should be powered by an AC power source when you use the PutDisk command in case the battery pack goes low while the flash memory is being overwritten. If the power goes down when using PutDisk, internal safeguards permit a resume of the flash programming process. In rare cases, drive C flash must be reloaded from the Boot Loader menu and you will lose data. Conseil Les périphériques JANUS 2010 et 2020 doivent être alimentés par une source de courant alternatif lors de l'exécution de la commande PutDisk étant donné le risque de décharge de la batterie pendant que la mémoire flash est écrasée. Si le courant est coupé pendant l'exécution de PutDisk, des mesures de sécurité internes font en sorte de remettre en opération le processus de programmation flash. Il peut arriver, quoique rarement, qu’il faille recharger la mémoire flash du lecteur C à partir du menu Chargeuramorce (Boot Loader) et que des données soient perdues. 3. If you created the image file on the host computer and want to load it to the JANUS device from the host, start Interlnk now (with the host as server, and the JANUS device as client). Note: You can simply reboot the JANUS device after the connected host has Interlnk installed. You do not have to start Interlnk if you followed one of these strategies: •

You created the image file on the JANUS device.

•

You created the image file on the host computer, copied the file to a PC card, and inserted the PC card into the JANUS device.

3-27

Page 117

JANUS 2020 Hand-Held Computer User’s Manual (4MB) NFBC

4. Type this command on the JANUS device: putdisk /d=[drvletter] /i=[image filename] where: drvletter is the target JANUS drive to be updated. The default is drive C.

image filename is the name of the drives C or D image file created by MakeDisk. If you do not specify a path and filename, PutDisk looks for DRIVE_C.IMG.

You may receive error messages in the following conditions: •

If the specified file does not exist, PutDisk displays an error message and terminates.

•

If you specify a path without a file name, PutDisk also displays an error message.

•

PutDisk generates an error message if you attempt to put a DRIVE_C.IMG on drive D or a DRIVE_D.IMG on drive C.

Note: PutDisk will overwrite all files on drives C or D. For example, to copy the C-ATA.IMG image file from a PC card on the JANUS device to the JANUS drive C, type this command: putdisk /i=g:\c-ata.img

PutDisk tries to determine if there is adequate power before replacing the drive image. If a power problem exists, PutDisk displays an error message and terminates. You see messages on the JANUS device as PutDisk updates drives C or D, erases flash memory, and copies the DOS and new drives C or D image file to the JANUS device, and warm boots the JANUS device. If an error occurs, see Chapter 10, “Troubleshooting.”

Examples of Using MakeDisk and PutDisk Following are three examples of how you can use MakeDisk and PutDisk to change the contents of drives C or D:

3-28

•

In the first example, you run MakeDisk on the host, transfer the image file to the JANUS device on a PC card, and run PutDisk on the JANUS device to load the image file to drive C.

•

In the second example, you run MakeDisk on the host, use Interlnk to make the image file appear as if it were on the JANUS device, and run PutDisk on the JANUS device.

Page 118

NF

•

BC Learning About the Software

3

In the third example, you run MakeDisk on the host, transfer the image file to the JANUS device on a PC card, and run PutDisk on the JANUS device to load the image file to drive D.

Example 1 In this example, the resulting image file will be larger than 256K, so you must create the image file on the host computer if the JANUS RAM drive is configured at 256K (factory default). This example assumes that the host computer and the JANUS device can share a PC card. 1. Connect the JANUS device to a host computer using an appropriate serial connection. 2. Create a source directory on the host computer by typing this command at the host computer’s DOS prompt: mkdir c:\drivec

3. Fill the source directory with all the files you want to include in the new image file: a. Copy the files from the current drive C to the source directory. Because the host computer and JANUS device can share a PC card, you can insert the card into the JANUS PC card drive and copy all files from drive C to drive G. Then insert the card into the host computer’s PC card drive and copy all the files to the source directory. b. Add any other files and/or subdirectories to the working directory that you want on drive C. These files may include source read-only data files and applications for your JANUS device. c. Edit AUTOEXEC.BAT, CONFIG.SYS, and other files in the source directory as necessary. 4. Insert the JANUS Boot Utilities companion disk into a drive on the host PC. 5. Copy the self-expanding executable C_MAKE.EXE to drive C on the host PC by typing: copy a:\c_make.exe c:\

6

Run C_MAKE.EXE and delete all of the extracted files except for MAKEDISK.EXE.

7. Type this command at the host computer’s DOS prompt: makedisk /s=c:\drivec /o=newdrv.img

An image file, NEWDRV.IMG, is created in the working directory of the host computer’s drive C. Note: Do not create the image file in the directory where the source files reside.

3-29

Page 119

JANUS 2020 Hand-Held Computer User’s Manual (4MB) NFBC

8. Copy the image file from the host computer to the PC card and then insert the PC card into the JANUS PC card drive, drive G. Note: It is recommended that you provide an external power supply for the JANUS device before you execute PutDisk. 9. At the DOS prompt on the JANUS device, type this command to load the new image file onto drive C. putdisk /i=g:\newdrv.img

Example 2 In this example, you create the image file on the host computer, use Interlnk to make the image file appear as if it were on the JANUS device, and use PutDisk to load the image file to drive C. 1. Connect the JANUS device to a host computer using an appropriate serial connection. 2. Create a source directory on the host computer by typing this command at the host computer’s DOS prompt: mkdir c:\drivec

3. Fill the source directory with all the files you want to include in the new image file: a. Copy the files from the current JANUS drive C to the source directory on the host PC. Use Interlnk with the host computer as the client and the JANUS device as the server. b. Add any other files to the source directory that you want on drive C. These files may include read-only data files and applications for your JANUS device. Note: Do not create the image file in the directory where the source files reside. c. Edit AUTOEXEC.BAT, CONFIG.SYS, and other files in the source directory as necessary. 4. Insert the JANUS Boot Utilities companion disk into a drive on the host PC. 5. Copy the self-expanding executable C_MAKE.EXE to drive C on the host PC by typing: copy a:\c_make.exe c:\

6

3-30

Run C_MAKE.EXE and delete all of the extracted files except for MAKEDISK.EXE.

Page 120

NF

BC Learning About the Software

3

7. Type this command at the host computer’s DOS prompt: makedisk /s=c:\drivec /o=newdrv.img

MakeDisk creates an image file, NEWDRV.IMG, in the working directory of the host computer’s drive C. 8. Restart Interlnk. Make the JANUS device the client, and the host computer the server. The new image file, NEWDRV.IMG, appears on the H drive root directory. 9. At the DOS prompt on the JANUS device, type this command to load the image file to drive C. putdisk /i=h:\newdrv.img

Example 3 In this example, the resulting image file will update drive D. Since the image file will be larger than 256K, you must create the image file on the host computer if the JANUS RAM drive is configured at 256K (factory default). This example assumes that the host computer and your JANUS device can share a PC card. 1. Connect the JANUS device to a host computer using an appropriate serial connection. 2

Create a source directory on the host computer by typing this command at the host computer’s DOS prompt: mkdir c:\drived

3. Fill the source directory with all the files you want to include in the new image file: a. Copy the files from the current drive D to the source directory. Because the host computer and your JANUS device can share a PC card, you can insert the card into the JANUS PC card drive and copy all files from drive D to drive G. Then insert the card into the host computer’s PC card drive and copy all the files to the source directory. b. Add any other files and/or subdirectories to the source directory that you want on drive D. These files may include read-only data files and applications for your JANUS device. 4. Insert the JANUS Boot Utilities companion disk into a drive on the host PC. 5. Copy the self-expanding executable C_MAKE.EXE to drive C on the host PC by typing: copy a:\c_make.exe c:\

6

Run C_MAKE.EXE and delete all of the extracted files except for MAKEDISK.EXE.

3-31