The text of a manual · part 4 of 9
EasyCoder E4 Bar Code Label Printer Installation & Operation: 4. Printer Setup
Pages 25 to 33 of 79, from EasyCoder E4 Bar Code Label Printer Installation & Operation
The original document is the PDF (1.5 MB). This is its text as extracted, unedited; tables and drawings read best in the PDF, and each page heading opens it at that page.
For the Intermec E4
Page 25
Chapter 4
Printer Setup Setup Methods
There is a number of methods you can use to set up the printer for the desired type of serial communication and control the printing according to type and size of media and in regard of print speed. The printer is always provided with the EasyCoder E4 Direct Protocol. This chapter mainly explains how to set up the printer using the Direct Protocol. There is also a number of supporting software packages from Intermec that can send setup data to the printer in a form that the Direct Protocol understands. Thus, you do not have to type intricate commands but only have to click an option or enter some data in menus presented in a Windows-compatible environment. The following software allows you to set up the printer: • Intermec PrintSet v2.1 or later • Intermec InterDriver with or without ActiveX controls • Intermec LabelShop (various versions) The number of setup options may vary according to type of software. Please refer to the manual or the on-line help that came with the software in question. Even if you use a software package to set up the printer, you may find this chapter instructive as it explains what the various options stand for and what choices you have. You can find more information on the EasyCoder E4 Direct Protocol in Appendix 4. For a full description, please refer to the EasyCoder E4 Direct Protocol, Programmer’s Guide.
24
Intermec EasyCoder E4 – Installation & Operation Ed. 2
Page 26
Chapter 4 Printer Setup
Communication Setup
The EasyCoder E4 can receive data on both the parallel and serial port, so there is no need to specify which port is to be used: • Either compose a text file containing the required setup commands and send it to the printer via the parallel port, • or establish two-way serial communication between printer and host computer as described below. To set up two-way serial communication with the EasyCoder E4: 1 Print out a test label to check the printer’s RS-232 serial port setting (see Chapter 3, “Operation; Printing Test Labels.)” 2 Configure the serial port on your host computer to match the printer’s settings. 3 Use the SYSVAR(18)= n command to set what kind of information will be passed back from the printer (called the Verbosity Level.) 4 Use the SETUP command to configure the serial port settings. SYSVAR Verbosity Level settings: -1 All levels enabled (Default) 0 No verbosity 1 Echo received characters 2 “OK” after correct command lines 4 Echo input characters from communication port 8 Error after failed line Bits can be combined so for example SYSVAR(18)=3 means both “Echo received characters” and “OK after correct command lines”. Once the printer and computer can communicate using the default serial port settings, you can change the settings to whatever communications settings you require, first on the printer and then on the computer. Once you have established a working serial communication both ways between printer and host, you can use the command to configure the printer as described on the following pages.
Intermec EasyCoder E4 – Installation & Operation Ed. 2
25
Page 27
Chapter 4 Printer Setup
Communication Setup, cont.
By default, the serial port is set for 9600 baud, no parity, 8 data bits, 1 stop bit, XON/XOFF disabled both ways. Note that as soon as a parameter is changed, you must change the setup of the host the same way, or the communication will be lost. • Baud Rate This setting controls the speed of the serial communication between printer and host (1 baud = 1 data bit per second.) There are 8 options: 300 600 1200 2400 4800 9600 19200 38400 Setup string, example: SETUP "SER-COM,UART1,BAUDRATE,9600" ↵
• Parity This setting controls how the software will check for errors in the serial communication. There are 5 options: None Even Odd Mark Space Setup string, example: SETUP "SER-COM,UART1,PARITY,NONE" ↵
• Character Length This setting controls how many bits are used to specify a character in the serial communication. There are two options: 7 Characters ASCII 0-127 dec. can be transmitted 8 Characters ASCII 0-256 dec. can be transmitted Setup string, example: SETUP "SER-COM,UART1,CHAR↔LENGTH,7" ↵
• Stop Bits This setting controls how many bits are used to specify a stop character in the serial communication. There are two options: 1 or 2 In the setup string examples, a double-headed arrow (as in “CHAR↔ LENGTH”) indicates a mandatory space characters in the command line.
Setup string, example: SETUP "SER-COM,UART1,STOPBITS,1" ↵
Quotation marks (" ") are ASCII 34 dec.
26
Intermec EasyCoder E4 – Installation & Operation Ed. 2
Page 28
Chapter 4 Printer Setup
Communication Setup, cont.
• Data Flow Control Data flow control determines serial communication between printer and host. It prevents characters being lost when data is transferred between printer and host at high speeds over the RS-232 serial port. It is important that the printer and host have the same configuration. There are three recommended settings for controlling data flow between printer and host.
Note: It is not recommended that you enable XON/XOFF, Data to Host.
- No flow control RTS/CTS is disabled XON/XOFF, Data from Host is disabled. XON/XOFF, Data to Host is disabled - RTS/CTS This protocol controls communication by handshake signals through separate wires in the cable. RTS/CTS is enabled XON/XOFF, Data from Host is disabled. XON/XOFF, Data to Host is disabled - XON/XOFF, Data from Host This protocol controls communication using the special characters XON (ASCII 17 dec.) and XOFF (ASCII 19 dec.) which are transmitted on the same wires as the data. RTS/CTSisdisabled XON/XOFF, Data from Host is enabled XON/XOFF, Data to Host is disabled Setup strings, examples: SETUP "SER-COM,UART1,FLOWCONTROL,RTS/CTS,DISABLE" ↵ SETUP "SER-COM,UART1,FLOWCONTROL,XON/XOFF,DATA↔TO↔HOST,DISABLE" ↵ SETUP "SER-COM,UART1,FLOWCONTROL,XON/OFF,DATA↔FROM↔HOST,ENABLE" ↵
In the setup string examples, a double-headed arrow (as in “CHAR↔ LENGTH”) indicates a mandatory space characters in the command line.
• New Line Character This setting specifies the character(s) transmitted from printer to host to initiate switching to a new line: - CR (ASCII 13 dec.) - LF (ASCII 10 dec.) - CR/LF (ASCII 13 + ASCII 10 dec.)
Quotation marks (" ") are ASCII 34 dec. Intermec EasyCoder E4 – Installation & Operation Ed. 2
27
Page 29
Chapter 4 Printer Setup
Print Location Setup
Recommended Adjustments: Dispensing (Label w gaps): Start Adjust : -119 Stop Adjust: -33 Tear Off (Ticket w mark): Start Adjust: -152 Stop Adjust: 0 Tear Off (Label w gap): Start Adjust: -152 Stop Adjust: 0 Tear Off (Var. Length Strip): Start Adjust: -136 Stop Adjust: +75 Tear Off (Fix Length Strip): Start Adjust: -136 Stop Adjust: +150 Cut Off (option): Start Adjust: -250 Stop Adjust: +180
In the setup string examples, a double-headed arrow (as in “CHAR↔ LENGTH”) indicates a mandatory space characters in the command line. Quotation marks (" ") are ASCII 34 dec. 28
• Media Feed Adjustments There are two settings that control the amount of blank media to be fed before the actual printing starts and after it is completed: - Start Adjustment This setting feeds out or pulls back a specified length of media before the printing of a label, ticket, or portion of continuous stock starts. The value is entered as dots, where a positive value (no leading minus sign) feeds out the media and a negative value (leading minus sign) pulls it back. - Stop Adjustment This setting works the same way as the Start Adjustment, but is executed after the printing of a label etc. is completed. By means of these two settings, you can, for example, control the media feed so the printing starts at the top of the label and the media still can be torn off in the gap between two labels. Setup strings, examples: SETUP "DETECTION,FEEDADJ,STARTADJ,-136" ↵ SETUP "DETECTION,FEEDADJ,STOPADJ,75" ↵
• Print Window The area on the media which can be used for printing (print window), is specified by means of three parameters, which are all given as a positive number of dots. It is important to set the print window so no printing can occur outside the media or ribbon, which may shorten the life of the printhead due to overheating. - X-Start Specifies an offset from the innermost dot on the printhead. When the X-Start value is set to 0, the print area starts 1 mm (0.04 inches) from the edge of the media, that is closest to the printer’s center section. By increasing the X-Start value, you can move the origin (X=0) outwards, making the inner margin wider. - Width Specifies the width of the print area, starting from the position of the origin as defined by the X-Start value. The sum of the X-Start and Width values must not exceed the width of the printhead (832 dots.) - Length Specifies the length of the printable area from the origin and along the Y-axis. This value decides the maximum amount of media feed when using any media type except “Var. length strip” (see Media Type below.) In case of labels, tickets, tags, or fixed portions of strip, enter the exact length.
Intermec EasyCoder E4 – Installation & Operation Ed. 2
Page 30
Chapter 4 Printer Setup Setup strings, examples:
Print Location Setup, cont.
SETUP "SERVICE,MEDIA↔SIZE,XSTART,30" ↵ SETUP "SERVICE,MEDIA↔SIZE,WIDTH,600" ↵ SETUP "SERVICE,MEDIA↔SIZE,LENGTH,800" ↵
From media supply 1 mm (0.04 inches)
9 mm (0.35 inches)
Length (y-dimension)
104 mm (4.1 inches)
PRINT WINDOW
Origin (x=0; y=0) Dot-line on printhead
X-start
Width (x-dimension) FEED DIRECTION
Dot 0 Path of 12 mm Label Stop Sensor & (0.47 Label Taken Sensor inches)
Dot 831 max. 114 mm (4.49 inches)
Intermec EasyCoder E4 – Installation & Operation Ed. 2
29
Page 31
Chapter 4 Printer Setup
Media Setup
• Media Type The EasyCoder E4 can be set to handle five different types of direct thermal media or receiving face material: - Label with gaps - Ticket with marks - Ticket with gaps - Fixed length strip - Variable length strip Refer to Appendix 2 for illustrations and specifications of the various types. It is important to specify the correct type, so the media feed will work correctly and the label stop sensor can detect the front edges of labels, tickets, and tags as well as out-of-paper conditions. Setup strings, examples: SETUP "SERVICE,MEDIA↔TYPE,LABEL↔(w↔GAPS)" ↵ SETUP "SERVICE,MEDIA↔TYPE,TICKET↔(w↔MARK)" ↵ SETUP "SERVICE,MEDIA↔TYPE,TICKET↔(w↔GAPS)" ↵ SETUP "SERVICE,MEDIA↔TYPE,FIX↔LENGTH↔STRIP" ↵ SETUP "SERVICE,MEDIA↔TYPE,VAR↔LENGTH↔STRIP" ↵
• Paper Type In order to be compatible with previous Intermec printers, the EasyCoder E4 is preset to use a number of standard media and ribbon qualities. Select the appropriate “Paper Type” setting among those listed in Appendix 2. More preferred ways of setting up the printer for different ribbons and receiving face materials are described in “New Supplies” below and in Appendix 5, “Printer Setup with the Bar Code Wand.” Setup string, example: SETUP “SERVICE,PRINT↔DEFS,PAPER↔TYPE,UBI↔HP↔07” ↵
In the setup string examples, a double-headed arrow (as in “CHAR↔ LENGTH”) indicates a mandatory space characters in the command line. Quotation marks (" ") are ASCII 34 dec. 30
• New Supplies When using direct thermal media and transfer ribbons, you can send a text string to the printer to indicate the supply type. See Appendix 2 for recommended “New Supplies” settings. This method of setting up the printer is preferred to obtain the best print quality and printhead lifetime. Instead of using a computer, you can also easily set up the media and ribbon type using the Bar Code Wand. The necessary codes are shown in Appendix 5. This gives you the same optimized results as “New Supplies” setup strings. Intermec EasyCoder E4 – Installation & Operation Ed. 2
Page 32
Chapter 4 Printer Setup Always use ribbons and labels from Intermec. These have been carefully matched with the printhead. Other ribbons and labels may shorten the life of the printhead.
Media Setup, cont.
Setup string, examples: Direct thermal printing (Economy grade) SETUP "SERVICE,PRINT↔DEFS,NEW↔SUPPLIES,GQ90" ↵
When setting the printer for thermal transfer printing, two “New Supplies” setup strings have to be used; one for the transfer ribbon and another for the receiving face material, for example: HP07 ribbon: SETUP "SERVICE,PRINT↔DEFS,NEW↔SUPPLIES,GF100" ↵
Matt coated face stock: SETUP "SERVICE,PRINT↔DEFS,NEW↔SUPPLIES,GZ0" ↵
Print Setup
• Performance This setting controls the print speed: - Normal Nominal speed 100 mm/sec. (4 inches/sec.) - High Nominal speed 150 mm/sec. (6 inches/sec.) Normal print speed gives the best printout quality for demanding layouts, containing for example ladder style bar codes or fine-detailed images. However, high speed gives an acceptable quality for most applications. Setup strings, examples: SETUP "SERVICE,PERFORMANCE,NORMAL" ↵ SETUP "SERVICE,PERFORMANCE,HIGH" ↵ •
In the setup string examples, a double-headed arrow (as in “CHAR↔ LENGTH”) indicates a mandatory space characters in the command line.
Contrast This setting controls the darkness of the printing on the paper. The range is 0-10, where 0 is the lightest and 10 is the darkest. To obtain the best printout quality, the contrast should be set to 5 (default) when using “New Supplies” setup strings or a Bar Code Wand for setting up the printer in regard of ribbon and labels. Setup string, example: SETUP "CONTRAST,5" ↵
Quotation marks (" ") are ASCII 34 dec. Intermec EasyCoder E4 – Installation & Operation Ed. 2
31
Page 33
Chapter 4 Printer Setup
Testfeed
The label length is defined as the distance between gaps, detection slots, or black marks. Measure the actual distance from the rear end of a gap or slot to the start of next gap or slot. In case of black marks, measure the distance between the forward edges of two adjacent marks and subtract the value expressed in dots by 16. By using a TESTFEED command, a blank label is fed out while the label length is automatically measured and stored in the printer’s flash memory, and the sensitivity of the label stop sensor is adjusted according to the characteristics of the presently loaded media. It is recommended to send a TESTFEED command every time you change to a new label/ticket length or media type! When using labels/tickets with a length exceeding 24 cm (9.5 inches), the TESTFEED command does not work, so the label length must be set manually using both of the two following setup commands. SETUP "SERVICE,TESTFEED,LENGTH,<length in dots>" ↵ SETUP "SERVICE,MEDIA↔SIZE,LENGTH,<length in dots>" ↵
The default value is 1200 dots (150 mm/5.9 inches.)
In the setup string examples, a double-headed arrow (as in “CHAR↔ LENGTH”) indicates a mandatory space characters in the command line. Quotation marks (" ") are ASCII 34 dec. 32
Intermec EasyCoder E4 – Installation & Operation Ed. 2