Page 31
Developing the Site Plan
2
If SmartPass is installed in an overhead location, tags should be installed in the center windshield in the top center area behind the rear view mirror or on the vehicle’s front license plate or center bumper as illustrated in Figure 2-5.
Figure 2-5 Typical Tag Positions for SmartPass Mounted Overhead
Note: Metallized coatings on some vehicle windshields and windows shield the radio frequency energy emitted by SmartPass, and may cause tags to be misread. Always install tags on the exterior of vehicles having this type of window coating. Refer to Chapter 3 for more detailed information on tag positioning.
Site Layout and Traffic Flow Site layout and traffic flow considerations are critical when determining SmartPass installation locations. These factors include the following:
•
SmartPass read zone
•
Other SmartPasses in the area
•
Lane configurations
•
Reflection, refraction, and diffraction of RF signals
•
Existing signal interference at the site
2-7
Page 32
AI1620 SmartPass System Guide
SmartPass Read Zone SmartPass must be able to read the tag data properly within a specified area, called the read zone, without reading other nearby tags or interfering with other SmartPasses at the site. The following are some of the factors that affect the size and shape of the read zone:
•
Mounting method used (pole or wall mount)
•
Height from the ground
•
Indoor or outdoor location
•
Range discrimination setting
•
Other sources of interference and reflection
SmartPass must be positioned to allow the RF signal to travel to and return from the tags within the designated range and be placed in an area where it is not likely to be bumped out of alignment. If the antenna becomes misaligned or some nearby structure is added or removed, system operation can be seriously affected. For instructions on setting the read zone, see “Marking the Read Zone” on page 8-14.
Other SmartPasses in the Area Sites with more than one SmartPass in close proximity should be configured with a frequency separation of at least 6 MHz. If more than one SmartPass is in a side-byside or multiple lane application, the frequencies should be staggered. Also, two SmartPasses will not operate accurately if they directly face each other.
Lane Configurations Amtech recommends that traffic be guided through a controlled lane to obtain consistent accurate tag readings and to prevent damage to SmartPass. The following subsections describe some common lane configurations and give suggestions for positioning SmartPass within the controlled traffic flow.
Open Lane Configuration An open lane configuration is one in which no center barrier separates two opposing traffic flows. Figure 2-6 illustrates a sample open lane configuration and SmartPass placement. This figure assumes that tags are mounted on the inside windshield on the passenger side (U.S.) of the vehicle.
2-8
Page 33
Developing the Site Plan
Direction of
Presence
Tag Read Zone
SmartPass v
16 ff minimum a
Tag Read Zone, , ee ee ee
Presence
LOOD
Direction of
Traffic Flow
Figure 2-6 Open Lane Configuration
Page 34
AI1620 SmartPass System Guide
Another option for SmartPass placement in an open lane configuration is one in which SmartPass is mounted overhead in each lane as illustrated in Figure 2-7. This figure assumes that tags are mounted on the inside center windshield or center bumper of the vehicle.
Figure 2-7 Overhead Open Lane Configuration
2-10
Page 35
Developing the Site Plan
2
Gate with Center Island Configuration Figure 2-8 illustrates a typical gate application with SmartPass units positioned on a center island to read tags mounted on the inside windshield on the driver’s side (U.S.). The readers are placed to allow time for the gate to open so that the vehicle can roll through without stopping.
Figure 2-8 Gate Application with Center Island
Parking Garage with Ticket Island Configuration Figure 2-9 illustrates a parking garage application with each SmartPass mounted on the ticket island to read tags mounted on the inside windshield on the driver’s side (U.S.) or on the front vehicle bumper. SmartPass is placed to require the vehicle to stop before the gate opens.
2-11
Page 36
AI1620 SmartPass System Guide
Figure 2-9 Parking Garage Application
Reflection, Refraction, and Diffraction of RF Signals RF signals can be reflected, refracted, or diffracted by metal objects, walls, and even wet pavement or ice. Any of these effects can alter or degrade system performance. When designing your site plan, you must consider permanent structures and transient factors in the vicinity that may affect RF signals being generated by SmartPass. Permanent structures include buildings, chain link fences, guard shacks, and gates. Transient factors include passing traffic and local weather conditions such as rain or snow. Symptoms of these effects would include reading tags that are out of the desired read zone, or cross-lane reads. The most common RF reflectors are metallic surfaces. RF signals may be partially reflected by nonconducting materials such as dirt, wood, ice, asphalt, and concrete. When nonconducting materials in the system environment become wet, they increase reflection of RF signals. SmartPass mounting location, aiming, range control adjustment, discussed in Chapter 8, and use of presence detectors can reduce interference from RF reflections. When these actions cannot adequately control reflections, other techniques such as shielding, absorbing, range sensitivity adjustment, or barriers can also be used. See Chapter 9.
2-12
Page 37
Developing the Site Plan
2
Existing Interference Interference from RF and electrical sources can degrade system performance and must also be considered in the site design. Fluorescent lights, neon signs, nearby radio stations, or power lines can interfere with the optimal operation of the system. The magnetic impulse noise from relays that control gate opening and closing can also disrupt the RF signal. Existing interference at the site may be shielded, removed, or positioned further from the SmartPass. In some cases, changing the operating frequency of the SmartPass may provide a simple solution. See Chapter 9.
Electrical and Communications Requirements All construction work at the site must be completed before installing SmartPass. Electrical and communications cables should be installed according to all applicable local and federal building code requirements. Specific instructions to position and install SmartPass are in Chapter 8.
Junction Box A watertight junction box meeting applicable local and national building codes is recommended for connecting SmartPass power and communications wiring. Amtech recommends a NEMA Type-4 junction box with a back panel. The junction box will house the terminal strip for communications and power connections.
Power and Communications Cable The appropriate cable length for power and communications depends on the physical characteristics of SmartPass installation site. Table 2-1 lists accessory kits available for cabling options based on your site’s requirements. Table 2-1 Connector Cabling Accessory Kits Part Number
Description
58-1620-001
5-ft connector cable
58-1620-002
20-ft connector cable
20-1620-003
Connector kit only
56-1620-004
13-Pair cable (1-ft lengths)
76-1620-005
110 V AC to 18 V AC Class C transformer
76-1620-006
12 V AC to 18 V AC step-up transformer
2-13
Page 38
AI1620 SmartPass System Guide
Electrical Power A dedicated electrical power supply must be present at the site and be available to SmartPass at all times. The power must be 16–28 V DC or 16–20 V AC. A step-down transformer is available (North America only) to convert a 120 V AC duplex wall outlet with ground to 18 V AC, or a step-up transformer to convert a low-voltage 12 V AC outlet to 18 V AC. Consult your local and national electrical codes for installation and safety requirements. Note: SmartPasses installed outside North America will require a locally supplied transformer. If 18 V DC or 18 V AC power is available, the transformer option will not be necessary. Amtech offers a Class C transformer accessory kit (part number 76-1620-005) for sites where 110 V AC is available. It is the installer’s responsibility to supply conversion equipment and wiring for other voltages. Table 2-2 contains power supply current requirements. Table 2-2 Power Supply Current Requirements
Supply
Worst Case Maximum Current at 68°F (20°C)
Standby Operating Current at 68°F (20°C)
16 to 20 V AC
800 mA at 18 V AC
400 mA at 18 V AC
16 to 28 V DC
800 mA at 18 V DC
400 mA at 18 V DC
Power circuits are protected internally against power surges.
Power Extension Measured voltage at SmartPass must be at least 16 V for proper operation. Use Table 2-3 to determine the correct cable size for the necessary cable length. The table is an approximation.
2-14
Page 39
Developing the Site Plan
2
Note: If close to the maximum length, measure voltage at SmartPass to ensure it does not drop below 16 V. Table 2-3 Cable length from Amtech-Supplied 110 V AC to 18 V AC Transformer to AI1620 SmartPass Cable Size (AWG)a
24
22
20
18
16
14
12
Maximum DCR (Ohms per foot at 68° F)b
0.0270
0.0175
0.0109
0.0069
0.0044
0.0027
0.0017
Maximum length (feet)
29.63
45.71
73.39
115.61
183.91
293.04
467.84
Maximum length (feet) c
25
39
62
98
156
249
398
When used to extend Amtech 5-ft cable (feet)
23
36
57
90
143
227
363
When used to extend Amtech 20-ft cable (feet)
14
22
35
55
88
140
224 a. Use two conductors each for 18 V and 18 V return (4 conductors total). b. DCR information is from Belden catalog. c. Calculated length is reduced by -15% to adjust for other variables such as connector contact resistance. Length variable factor is 85%; maximum current drawn by AI1620 is 2.5; maximum allowable voltage drop from the 18 V AC transformer secondary is 2.
Host Communications Your site design must include communications between SmartPass and a host computer. SmartPass communicates with the host computer through an asynchronous serial line or through a Wiegand interface. This serial line can be an RS–232 interface or an RS–422 interface. The host computer must be able to accept one of the interfaces shown in Table 2-4. Table 2-4 Communications Interfaces and Conductors
Interface
Number of Conductors
RS–232
3
RS–232 with RTS and CTS hardware and handshake signals
5
RS–422
4
Wiegand
3
Communications circuits are protected internally against power surges. Select one of the following communications interfaces based on the specific needs of your site.
2-15
Page 40
AI1620 SmartPass System Guide
RS–232 Interface Use an RS–232 interface if one or more of the following items apply to your site:
•
The host computer system is 50 ft (15.2 m) or less from SmartPass.
•
The host computer system is more than 50 ft (15.2 m) from SmartPass, and a pair of RF modems or limited distance modem/line drivers over copper wire are used for communications between SmartPass and the host. The distance from the RF modem to SmartPass should not exceed 50 ft (15.2 m).
•
Other common communications devices that use RS–232 have been selected, such as fiber optics.
RS–422 Interface Use an RS–422 interface if one or more of the following items apply to your site:
•
The host computer is more than 50 ft (15.2 m) from SmartPass.
•
The host computer has an external limited-distance modem.
The standard RS–422 connection maximum distance depends on the baud rate, cable type, and the RS–422 device at the other end.
Wiegand Interface SmartPass can interface with equipment requiring the Wiegand +5 V DC data0-data1ground interface. It does so using the Wiegand interface included with the RS–232 or RS–422 option. Note: SmartPass comes from the factory with both the RS–232 or RS–422 option
AND Wiegand. If you wish to use Wiegand, you must first connect SmartPass using the RS–232 or RS–422 interface, set SmartPass’s configuration to Wiegand, and then connect SmartPass using the Wiegand interface. Note: You must order tags programmed with Wiegand-formatted data when using a Wiegand-compatible reader.
Input/Output Circuits To connect SmartPass to external equipment such as a treadle or traffic control light, install wires from these devices at the junction box. SmartPass input circuit is designed to connect to a dry contact closure. SmartPass output circuits are single-pole, double-throw relays providing dry contact closures. These contacts are rated at 42.2 V AC peak, or 60 V DC, at 1 A maximum. Output circuits are not intended for the direct control of electromechanical devices such as motorized gates and barrier arms. For such applications, the SmartPass output circuits should be used to drive a secondary, appropriately rated high-power relay.
2-16