Page 201
B Technical Specifications
Page 202
Page 203
Technical Specifications
B
Reader Specifications Communications Frequency Selection
902 to 904 and 909.75 to 921.75 MHza
Reading Range
Optimal: 12 ft. (3.66 m) Maximum: 60 ft. (18.29 m)b a. Operation in the United States is regulated by the Federal Communications Commission (FCC). Local regulations apply. The user is required to obtain a license issued by the FCC. Contact Amtech for more information. b. Depending on system configuration and operating environment.
Hardware Features Integrated System
RF module, tag decoder, antenna, and power supply all housed in a single package.
Case
Weatherproof enclosure. The system is sealed in a tamper-proof, polycarbonate housing.
Power Requirements Input Power
16 to 20 V AC, 47 to 63 Hz or 16 to 28 V DC
Physical Attributes Size
15.5 x 15.5 x 3.25 in (39.4 x 39.4 x 8.25 cm)
Weight
9.5 lb (4.3 kg)
B-3
Page 204
AH1101 Handheld Reader User Guide
Environmental Parameters Operating Temperature
-40°F to +122°F (-40°C to +50°C)
Humidity
90% noncondensing
Vibration Tolerance
0.5 Grms, 10 to 500 Hz
Options
B-4
Communications Interface
RS-232 and Wiegand or RS-422 and Wiegand
Input Power
16 to 20 V AC, 47 to 63 Hz or 16 to 28 V DC
RF Power
High RF power: 2000 mW or low RF power: 500 mW
Tag Options
Can be selected to work with full-frame (128 bits) and half-frame (64 bits) tags
Page 205
C Wiring Tables
Page 206
Page 207
Wiring Tables
C
The following tables show the wiring connections used to install and test SmartPass. For information on testing SmartPass, refer to Chapter 4. For information on installing SmartPass, refer to Chapter 8.
Communications Interfaces Table C-1 Communications Interfaces and Conductors
Interface
Number of Conductors
RS–232
3
RS–232 with RTS and CTS hardware handshake signals
5
RS–422
4
Wiegand
3
C-3
Page 208
AI1620 SmartPass System Guide
Figure C-1 DB9 and DB25 Connector Pin Assignments for Signal to Host
Cable Supplied with SmartPass SmartPass may be delivered with a multiwire cable (ordered as a separate accessory), which is a 13-pair pigtail. In some instances, an alternate 15-pair pigtail may be substituted. The 13-pair pigtail is a colored wire pair cable, with different colors denoting the individual pairs, one pair of which is red/black. The alternate 15-pair pigtail is a red/black wire pair cable, with numbers on the pairs to denote the individual pairs. Two pairs of the 15-pair pigtail, numbers 14 and 15, are not used.
C-4
Page 209
Wiring Tables
C
RS–232 Interface Table C-2 RS–232 Interface Signal Wiring for Colored Wire Pair Cable Colored Pair Wire Cable Signal from SmartPass
Connect Wire to Host DB9 Pin
Connect Wire to Host DB25 Pin
Black
Pin 2
Pin 3
Red
Pin 3
Pin 2
Yellow or black
Pin 5
Pin 7
Yellow
Pin 8
Pin 5
Red
Pin 7
Pin 4
Wire Pair from Color SmartPass
TxD, SmartPass output
Used
Red/Black RxD, SmartPass input Signal ground
Yellow/ Black
Optional for hardware handshaking RTS, SmartPass output Yellow/Red CTS, SmartPass input
Table C-3
RS–232 Interface Signal Wiring for Alternate Wire Pair Cable Alternate Wire Cable
Connect Wire to Host DB9 Pin
Connect Wire to Host DB25 Pin
Black
Pin 2
Pin 3
Red
Pin 3
Pin 2
Black or Red
Pin 5
Pin 7
Black
Pin 8
Pin 5
Red
Pin 7
Pin 4
Signal from SmartPass Pairing TxD, SmartPass output
Color
Pair 1 RxD, SmartPass input Signal ground
Pair 5
Optional for hardware handshaking RTS, SmartPass output Pair 11 CTS, SmartPass input
C-5
Page 210
AI1620 SmartPass System Guide
RS-422 Interface Table C-4 RS–422 Interface Signal Wiring for Colored Wire Pair Cable Colored Pair Wire Cable Signal from SmartPass
Wire Pair from Color SmartPass
RS–422 Transmit positive
Connect to Signal from Host
Used Yellow
Receive (+)
Red
Receive (–)
Black
Transmit (+)
Red
Transmit (–)
Yellow/Red RS–422 Transmit negative RS–422 Receive positive Red/Black RS–422 Receive negative
Table C-5 RS–422 Interface Signal Wiring for Alternate Wire Pair Cable Alternate Wire Pair Signal from SmartPass Pairing RS–422 Transmit positive
Color
Connect to Signal from Host
Black
Receive (+)
Red
Receive (–)
Black
Transmit (+)
Red
Transmit (–)
Pair 11 RS–422 Transmit negative RS–422 Receive positive Pair 1 RS–422 Receive negative
C-6