Page 131
Commands
7
Reader message: IDAP T<0 to 1> D<0 to 1> X<0 to 1> where: T0 time not appended
T1 time appended (factory default)
D0 date not appended
D1 date appended (factory default)
X0 auxiliary information not appended (factory default)
X1 auxiliary information appended
One space is required between each value. For example, if factory default settings are assigned, the reader response is IDAP T1 D1 X0
Indicating time and date appended and auxiliary information not appended Note: Time and date may be appended to ID codes, error messages, presence without tag reports, and input status change reports. Auxiliary information may only be appended to ID codes, presence without tag reports, and input change reports.
525 Display Communications Protocol Status Command 525 displays selected communications protocol command 61N, selected mode of flow control command 614N, and ECP timeout command 612NN. Reader message: ECPS P<0 to 2> T<01 to FF> X<0 to 2> where: P0 basic protocol enabled (factory default)
P1
ECP enabled
P2 data inquiry protocol enabled
Txx
ECP timeout where xx = 01 to FE (hexadecimal) timeout (ms) = 50 * xx if xx = FF timeout disabled
X0 flow control disabled
X1 software flow control enabled (factory default)
X2 hardware flow control enabled
7-17
Page 132
AI1620 SmartPass System Guide
For example, if factory default settings are assigned, the reader message is: ECPS P0 TFE X1
Meaning:
basic protocol enabled, an ECP timeout of 254 (12,700 ms, 12.7 sec), and software flow control enabled
526 Display I/O Status Command 526 displays the current input/output status. The reader message indicates whether outputs are being controlled externally by the host through output control commands (620N) or internally through predefined output mode command 621. It also displays the current status of two outputs, two inputs, and the selected output pulse duration (set by output pulse duration command 67N). Reader message: IOST C<0 to 1> O<0 to 3> I<0 to 3> D<0 to F> where:
7-18
C0 host controls outputs
C1 predefined output mode
O0 both outputs off
O1 output0 on
O2 output1 on
O3 both outputs on
I0 both inputs false
I1 input0 true
I2 input1 true
I3 both inputs true
D0
4 ms output pulse duration
D1
8 ms output pulse duration
D2
12 ms output pulse duration
D3
16 ms output pulse duration
D4
20 ms output pulse duration
D5
24 ms output pulse duration
D6
32 ms output pulse duration
D7
40 ms output pulse duration
D8
48 ms output pulse duration
D9
60 ms output pulse duration
Page 133
Commands
DA
76 ms output pulse duration
DB
152 ms output pulse duration
DC
228 ms output pulse duration (factory default)
DD
300 ms output pulse duration
DE
376 ms output pulse duration
DF
752 ms output pulse duration
7
Note: The first character is alpha; the second character is numeric. The following table shows the output0 and output1 open/closed conditions for the output status displays. Output Status
Output0 Wire Pair
Output1 Wire Pair
Orange/Black
Brown/Black
White/Black
Green/Black
O0
Closed
Open
Closed
Open
O1
Open
Closed
Closed
Open
O2
Closed
Open
Open
Closed
O3
Open
Closed
Open
Closed
The following table shows the input0 and input1 open/closed conditions for the input status displays. Input
Input0 Wire Pair
Input1 Wire Pair
Status
Green/Red
Blue/Black
I0
Open
Open
I1
Closed
Open
I2
Open
Closed
I3
Closed
Closed
527 Display RF Status Command 527 displays the current status of the RF module. The reader response indicates whether RF is controlled externally by the host (command 640N) or internally by input (command 641). It also displays the current RF status and the uniqueness timeout, which is fixed at 2 minutes.
7-19
Page 134
AI1620 SmartPass System Guide
Reader message: RFST C<0 to 1> O<0 to 1> T1 Fx Rxx where: C0
RF controlled by host
C1
RF controlled by presence sensor on input0, the red/green pair (factory default)
O0
RF off
O1
RF on
T1 uniqueness timeout of 2 minutes (fixed)
Fxx
F = RF output frequency, xx = 00 to 34 hexadecimal offset in 500 kHz from 902 MHz. If an invalid frequency value is stored (corrupted NVRAM), then xx = “XX” to indicate an error in the frequency setting.
Rxx
R = RF output range (distance), xx = 00 to IF hexadecimal range value
For example, if factory default settings are assigned, the reader message is: RFST C1 O0 T1
Meaning:
RF-by-input control, RF signal off, and uniqueness timeout of 2 minutes
529 Display Presence Input Status Command 529 displays the parameters associated with presence detection and RF control. The reader’s message indicates if presence without tag reports are enabled/ disabled (690N), if input inversion is enabled/disabled (694N), and the minimum presence true period (always true). It also reports the selected RF timeout (693N) and the selected means of RF-off control (692N). If presence without tag reports is enabled (6901), the reader transmits a report if a presence is detected without the subsequent acquisition of a valid tag. Reader message: PRST P<0 to 1> D0
A<0 to 2> T<0 to F> I<0 to 1> where:
7-20
P0 presence without tag reports disabled (factory default)
P1 presence without tag reports enabled
D0 minimum presence true period of 0 ms (fixed)
A0
RF-off on timeout only
A1
RF-off on timeout or tag
A2
RF-off on timeout or presence condition false (factory default)
Page 135
Commands
T0
RF timeout of 0 ms (always expired)
T1
4 ms
T2
8 ms
T3
12 ms
T4
20 ms
T5
24 ms
T6
32 ms
T7
48 ms
T8
60 ms
T9
92 ms
TA
152 ms
TB
300 ms
TC
452 ms
TD
600 ms
TE
752 ms
TF infinite, never expires (factory default)
I0 input inversion disabled (factory default)
I1 input inversion enabled
7
For example, if factory default settings are assigned, the reader message is: PRST P0 D0 A2 TF I0
Meaning:
presence without tag reports disabled, minimum presence true period is 0, RF-off control on timeout or presence false, infinite RF timeout, and input inversion disabled
530 Display RF0 Filter Status Command 530 displays the parameter set for the RF channel input, including the selected unique ID code criteria (command 410N) and the valid ID code criteria, which are fixed at one acquisition. Reader message: RF0S U<0 to 3> V0 where: U0 one ID separation (factory default)
U1 two ID separations
U2 transmit all IDs
7-21
Page 136
AI1620 SmartPass System Guide
U3 buffer all IDs
V0 valid ID code criteria of one acquisition (fixed)
For example, if factory default settings are assigned, the reader message is: RF0S U0 V0
Meaning:
separation of one ID for uniqueness filtering and a valid ID code criteria of one acquisition
532 Display Wiegand Mode Status Command 532 displays Wiegand mode status enabled or disabled. Reader message: TOF <0 to 1> where: 0
Wiegand mode disabled
1
Wiegand mode enabled
533 Display Wiegand Retransmit Interval Command 533 displays the Wiegand retransmit interval. This interval specifies the delay (in seconds) before the reader retransmits Wiegand data for a tag still in the read zone. The factory default is 1 second. Reader message: WTI <01 to FF> where: 01 to FF seconds (1–255) in hexadecimal
534 Display Tag Translation Mode Status Command 534 displays tag translation mode status, enabled or disabled. If tag translation mode is enabled, incoming full-frame tags in AAR or ATA format are translated according to ISO standards. Refer to “452 Disable Tag Translation Mode (Factory Default)” on page 7-13 and “453 Enable Tag Translation Mode” on page 713 for more information. Reader message: TT <0 to 1> where:
7-22
0 tag translation mode disabled
1 tag translation mode enabled
Page 137
Commands
7
535 Display Buffer Control Status Command 535 displays buffer control mode status, enabled or disabled. Refer to “6160 Disable Buffer Control Mode (Factory Default)” on page 7-27 and “6161 Enable Buffer Control Mode” on page 7-28 for more information. Reader message: BCM <0 to 1> where: 0 buffer control mode disabled
1 buffer control mode enabled
536 Display Dual-Frame Processing Mode Command 536 displays the selected dual-frame processing mode. The mode used determines if frame A or frame B of a dual-frame tag resets uniqueness and which frame(s) are transmitted to the host, A, B, or both. Refer to “48N Select Dual-Frame Processing Mode” on page 7-14 for more information. Reader message: DUAL <0 to 3> where: 0 reset uniqueness on A, transmit A
1 reset uniqueness on B, transmit B
2 reset uniqueness on A, transmit both A and B
3 reset uniqueness on B, transmit both A and B
537 Display Echo Status Command 537 displays echo mode status. In basic protocol (610) and data inquiry protocol (613), the reader may be configured to enable (6171) or disable (6170) the echo of received commands. Refer to “6170 Disable Echo Mode” on page 7-29 and “6171 Enable Echo Mode (Factory Default)” on page 7-30 for more information. Reader message: ECHO <0 to 1> where: 0 echo status disabled
1 echo status enabled
7-23
Page 138
AI1620 SmartPass System Guide
540 Display Flash Checksum Command 540 displays the flash memory checksum. Reader message: PCKS I0000 Exxxx where: 0000 not applicable to SmartPass xxxx represents the 4-byte ASCII representation of the flash memory checksum
543 Display Boot Checksum Command 543 displays the boot ROM checksum. Reader message: BCKS xxxx where: xxxx represents the 4-byte ASCII representation of the boot ROM checksum
550 Display Periodic Check Tag Status Command 550 displays parameters for the periodic check tag function. The periodic check tag function may be enabled by command 8120 or disabled by command 810. The check tag interval is fixed at 30 minutes. If the check tag function is enabled by command 8110, the periodic function will be disabled. Reader message: SCTS M<0 to 1> T5 where:
7-24
M0 periodic check tag disabled (factory default)
M1 periodic check tag enabled
T5 periodic check tag interval of 30 minutes (fixed)
Page 139
Commands
7
551 Display Selected Check Tag Option Command 551 displays the currently selected check tag option. Refer to “8160 Select Internal Check Tag (Factory Default)” on page 7-41 for more information. Reader message: CTAG <0 to 1> where: 0 internal check tag option enabled (factory default)
1 external check tag option enabled
560 Display Input Status Change Report Options Command 560 displays the input status change reporting options. Status change reporting may be disabled by command 82N. Reader message: SSTC E<0 to 1>M<0 to 3> where: E0 input status change reports disabled (factory default)
E1 input status change reports enabled
M0 reporting disabled (factory default)
M1 changes on input0 reported
M2 changes on input1 reported
M3 changes on either input reported
For example, if factory default settings are assigned, the reader message is: SSTC E0 M0
Meaning:
input status change reports disabled on both input0 and input1
Reader Control Functions, Command Group 6 Group 6 commands set reader control functions such as reader ID, communication protocol, output pulse, and RF control.
60NN Set Reader ID Number Command 60NN sets the reader ID that will be sent in the auxiliary data field (command 311). Uppercase or lowercase characters are allowed for NN; for example, hex digits A–F or a–f where: NN
00 to FF (hex for 0 to 255, factory default = 00)
7-25
Page 140
AI1620 SmartPass System Guide
Reader message: Done
610 Select Basic Protocol (Factory Default) Command 610 selects the basic communications protocol. Refer to “Basic Protocol” on page 6-3 for more information. Reader message: Done or Error
611 Select Error Correcting Protocol Command 611 selects the error correcting protocol. Refer to “Error Correcting Protocol” on page 6-4 for more information. Reader message: Done or Error
Caution Do not switch to error correcting protocol (command 611) unless the host is prepared to acknowledge each reader transmission.
612NN Select Error Correcting Protocol Timeout Command 612NN selects the timeout interval for ECP. This timeout applies to the transmission of tag, report, and error messages and to the receipt of host commands. The transmit timeout is initiated immediately after the end-ofmessage sequence CR/LF is transmitted. If the host does not acknowledge the message within the specified interval, the reader will time out and retransmit the message. The receive timeout is initiated upon receipt of the start-of-message character (#). If the end-of-message character (CR) is not received within the specified interval, the reader will discard the partially received message and reset its receiver. The value for NN specifies the timeout interval as follows: ms
50 * NN for NN = 01 to FE (1–254)
FE factory default (12,700 ms, 12.7 sec)
FF disables the error correcting protocol timeout
Uppercase or lowercase characters are allowed for NN; for example, hex digits A–F or a–f. Reader message: Done or Error
A protection mechanism prevents the assignment of mismatched ECP timeout baud rate values. The reader transmits Error in response to command 612NN if the specified timeout (NN) is too short for the current baud rate. Refer to “Timing and Synchronization” on page 6-10 for more information.
7-26