Browse
(440) 299-7778
Menu
(440) 299-7778
One-year parts and labor warranty30-day money-back guaranteeEnglishEspañolContact

The text of a manual · part 14 of 14

9710 and 9720 Wedge Readers User's Manual, pages 131 to 138

Pages 131 to 138 of 138

The original document is the PDF (1.8 MB). This is its text as extracted, unedited; tables and drawings read best in the PDF, and each page heading opens it at that page.

For the Intermec 9710

Page 131

Glossary

G

Self-Checking

Characteristic of a bar code symbology that, without the use of a check digit, allows the bar code to be decoded without an error. Self-Test

The search for malfunctions in the electrical or mechanical systems of a device by its own actions. Serial

A communication scheme in which the bits of a byte are transferred one-at-a-time. Solicitation Message

A predefined message sent by the wedge reader to initiate data transmission from the device connected to the wedge reader serial port. Space

The lighter element of a bar code usually formed by the background between bars. Start and Stop Characters

Specified characters at the beginning and end of a bar code symbol that provides “direction of read” information to the reader decoding logic. Symbology

A scheme for encoding data as bar code. Code 39, Interleaved 2 of 5, and Codabar are examples of different symbologies. Timeout Delay

The specified time the reader waits between receiving characters from the serial port, before transmitting the data already received onto the workstation (if no EOM is received). Quiet Zone

The area immediately preceding the start character and following the stop character that contains no markings. This area is usually ten times the width of the narrow bar. G-11

Page 132

9710 and 9720 Wedge Readers User’s Manual UPC/EAN Code

Universal Product Code (UPC) is a subset of the European Article Numbering (EAN). The EAN code is also referred to as World Product Code (WPC) and International Article Numbering (IAN). It is used in marking items for retail sale. This code is fixed length, continuous, and weakly self-checking. It requires close printing tolerances. The character set is 0 - 9. Its maximum character density is 13.8 numeric characters per inch. Variable Length

A type of symbology in which the number of characters per symbol is not restricted. It is opposite of fixed length. Voting

A laser scanner parameter that takes more than one (low setting) or more than two (high setting) matching scans from the same label to yield a good read. This is useful when scanning poor quality labels that may cause substitution errors. This is for laser scanning only. Wait Character

A predefined character that delays the reader a set time (wait time) before the reader sends the next set of data to the workstation. Window

A Data Edit parameter that delays the reader a set time (wait time), before sending the next set of data to the workstation. XON/XOFF

A type of software flow control for communication between digital devices. It stops the host from sending data when the device buffer fills up (XOFF) and starts it again when the buffer empties (XON).

G-12

Page 133

I Index

Page 134

This page is a scan with no text; see it in the PDF.

Page 135

Index

Numbers

2 of 5 Code, 3-37 2 of 5 Code configuration example, 3-38 A

American Blood Commission (ABC) Codabar, 3-34 Application Program, 5-3 ASCII characters table, A-7 keycode customization, 3-45 keycode equivalent example, 3-46 terminal keyboard mapping, A-6 Automobile Industry Action Group (AIAG), 3-24 B

Backspace command, 2-5 bar code symbologies, 3-24 2 of 5 Code, 3-37 Codabar, 3-34 Code 11, 3-24 Code 39, 3-24 Code 49, 3-29 Code 93, 3-30 Code 128, 3-31 Code 16K, 3-33 Interleaved 2 of 5, 3-36 ISBT 128, 3-31 MSI Code, 3-39 Plessey Code, 3-39 UPC/EAN, 3-41 bar codes multiple-read, 2-4 regular, 2-4 Baud Rate parameter, 4-8 Beeper Volume parameter, 3-6 C cables, 1-4 Caps Lock parameter, 3-6

I

Change Configuration command, 2-5 checking communications, 1-10 checking connections, 1-8 Clear command, 2-5 Clear to Send, 4-11 Codabar, 3-34 Codabar configuration example, 3-35 Code 11, 3-24 Code 39, 3-24 Code 39 configuration example, 3-28 Code 49, 3-29 Code 93, 3-30 Code 128, 3-31 Code 16K, 3-33 Command Processing parameter, 3-7 command string, 2-5 commands Backspace, 2-5 Change Configuration, 2-5 Clear, 2-5 Default Configuration, 2-6 disabling, 3-7 enabling, 3-7 Enter, 2-6 Enter Accumulate, 2-6 Exit Accumulate, 2-7 Reset, 2-7 Transmit Message, 2-7 communications, checking, 1-10 concatenate Codabar, 3-35 ISBT 128, 3-31 configuration null, 1-9 parameters, 3-6 connecting power supply, 1-7 wand or scanner, 1-6 customizing ASCII keycode equivalents, 3-45

I-3

Page 136

9710 and 9720 Wedge Readers User's Manual

D

Data Begin parameter, 5-5 Data Bits parameter, 4-9 Data Edit parameters Application Program, 5-3 Data Begin, 5-5 Data End, 5-6 Data Identifier, 5-7 Data Source, 5-7 User-Defined Pattern, 5-9 Window, 5-4 Data End parameter, 5-6 Data Entry keyboards, 3-7 Data Identifier parameter, 5-7 Data Redirection parameter, 3-10 Data Source parameter, 5-7 Default Configuration command, 2-6 Default Configuration bar code, 3-5 default workstation configuration, 1-9 disabling commands, 3-7 E

Echo, 4-11 enabling commands, 3-7 Enter Accumulate command, 2-6 Enter command, 2-6 European Article Numbering Code (EAN), 3-41 examples applying user-defined pattern, 5-11 ASCII keycode equivalent, 3-46 2 of 5 Code definition, 3-38 Codabar definition, 3-35 Code 39 definition, 3-28 disabling/enabling reader commands, 3-7 keyboard modification, 3-48 MSI Code definition, 3-40 postamble definition, 3-20 preamble A definition, 3-18

I-4 solicitation message definition, 4-16 UPC/EAN definition, 3-43 wait configuration, 3-13 Exit Accumulate command, 2-7 F

Flow Control parameter, 4-11 full ASCII mode, 3-25 H headphone/speaker jack, 2-8 Health Industry Bar Code (HIBC), 3-24 I installation, preparing, 1-3 Intercharacter Delay parameter, 3-15 Interleaved 2 of 5 Code, 3-36 ISBT 128, 3-31 K keyboard equivalent tables, A-3 keyboard modification example, 3-48 M mixed-full ASCII, 3-26 modifying keyboard example, 3-48 mounting the reader, 1-11 MSI Code, 3-39 MSI Code configuration example, 3-40 multiple-read bar codes, 2-4 N non-full ASCII mode, 3-25 null configuration, 1-9 O operating states standard, 2-4 test and service, 2-3

Page 137

Index

P

Parity parameter, 4-8 PC/workstation keyboard mapping, A-4 pin assignments, 9720 serial port connector, 4-4 Plessey Code, 3-39 portable reader connecting to 9720, 4-4 uploading data to 9720, 4-6 postamble example, 3-20 parameter, 3-19 power applying, 1-9 requirements, 1-7 power supply connecting, 1-7 types, 1-7 preamble example, 3-18 parameter, 3-15 Q quotes ("), using in data strings, 3-15 R reader commands, 2-5 configuration parameters, 3-6 Default Configuration bar code, 3-5 disabling/enabling example, 3-9 headphone/speaker jack, 2-8 serial port, 2-8, 4-3 status beeps, 2-8 reader parameters Beeper Volume, 3-6 Caps Lock, 3-6 Command Processing, 3-7 Data Redirection, 3-10 Intercharacter Delay, 3-15 Postamble, 3-19

I

Preamble, 3-15 Scanner Mode, 3-21 Scanner Timeout, 3-22 Scanner Trigger, 3-21 Voting, 3-23 Wait Character, 3-11 Wait Time, 3-12 reader/keyboard cable, 1-4 reader/workstation cable, 1-4 Reset command, 2-7 RXEOM, 4-12 S scale uploading data to 9720, 4-7 connecting to 9720, 4-5 Scanner Mode parameter, 3-21 Scanner Timeout parameter, 3-22 Scanner Trigger parameter, 3-21 scanner, connecting, 1-6 serial port configuration parameters, 4-3 connecting to, 4-3 connecting scale to, 4-5 connecting portable reader to, 4-4 CTS/RTS, 4-11 pin assignments, 4-4 uploading data from portable reader, 4-6 uploading data from scale, 4-7 XON/XOFF, 4-11 serial port parameters Baud Rate, 4-8 Data Bits, 4-9 Echo, 4-11 Flow Control, 4-11 Parity, 4-8 RXEOM, 4-12 Solicitation Message, 4-14 Stop Bits, 4-9 Timeout Delay, 4-10 TXEOM, 4-13 solicitation message example, 4-16 parameter, 4-14 I-5

Page 138

9710 and 9720 Wedge Readers User's Manual standard operation, 2-4 status beeps, 2-8 Stop Bits parameter, 4-9 T

Timeout Delay parameter, 4-10 Transmit Message command, 2-7 troubleshooting, 1-11 twinax/coax terminal keyboard mapping, A-5 TXEOM, 4-13 U

Universal Product Code (UPC), 3-41 UPC/EAN, 3-41 UPC/EAN configuration example, 3-43 User-Defined Pattern, 5-9 User-Defined Pattern example, 5-11

V

Velcro mounting reader, 1-11 Voting, 3-23 W

Wait Character, parameter, 3-11 wait configuration example, 3-13 Wait Time parameter, 3-12 wand, connecting, 1-6 Wedge Interface (WIF) guide, 1-4 Window parameter, 5-4 wood screw mounting reader, 1-12 workstation configuration bar code, 1-9 default configuration command, 3-5 null configuration, 1-9 identification, 1-9 X

XON/XOFF, 4-11

I-6