Page 191

ASCII Charts

A

US ASCII Codes Binary0

Hex1

Dec2

C393

Char4

Binary0

Hex1

Dec2

C393

Char4

00000000

00

00

%U

NUL

00100000

20

32

SP

SP5

00000001

01

01

$A

SOH

00100001

21

33

/A

!

00000010

02

02

$B

STX

00100010

22

34

/B

"

00000011

03

03

$C

ETX

00100011

23

35

/C

#

00000100

04

04

$D

EOT

00100100

24

36

/D

$

00000101

05

05

$E

ENQ

00100101

25

37

/E

%

00000110

06

06

$F

ACK

00100110

26

38

/F

&

00000111

07

07

$G

BEL

00100111

27

39

/G

'

00001000

08

08

$H

BS

00101000

28

40

/H

(

00001001

09

09

$I

HT

00101001

29

41

/I

)

00001010

0A

10

$J

LF

00101010

2A

42

/J

*

00001011

0B

11

$K

VT

00101011

2B

43

/K

+

00001100

0C

12

$L

FF

00101100

2C

44

/L

,

00001101

0D

13

$M

CR

00101101

2D

45

/M

-

00001110

0E

14

$N

SO

00101110

2E

46

/N

.

00001111

0F

15

$O

SI

00101111

2F

47

/

00010000

10

16

$P

DLE

00110000

30

48

/O /P6

0

00010001

11

17

$Q

DC1

00110001

31

49

/Q

1

00010010

12

18

$R

DC2

00110010

32

50

/R

2

00010011

13

19

$S

DC3

00110011

33

51

/S

3

00010100

14

20

$T

DC4

00110100

34

52

/T

4

00010101

15

21

$U

NAK

00110101

35

53

/U

5

00010110

16

22

$V

SYN

00110110

36

54

/V

6

00010111

17

23

$W

ETB

00110111

37

55

/W

7

00011000

18

24

$X

CAN

00111000

38

56

/X

8

00011001

19

25

$Y

EM

00111001

39

57

/Y

9

00011010

1A

26

$Z

SUB

00111010

3A

58

/Z

:

00011011

1B

27

%A

ESC

00111011

3B

59

%F

;

00011100

1C

28

%B

FS

00111100

3C

60

%G

<

00011101

1D

29

%C

GS

00111101

3D

61

%H

=

00011110

1E

30

%D

RS

00111111

3E

62

%I

>

00011111

1F

31

%E

US

00111111

3F

63

%J

?

A-3

Page 192

IRL Programming Reference Manual

Binary0

Hex1

Dec2

C393

Char4

Binary0

Hex1

Dec2

C393

Char4

01000000

40

64

%V

@

01100100

64

100

+D d

01000001

41

65

A

A

01100101

65

101

+E e

01000010

42

66

B

B

01100110

66

102

+F f

01000011

43

67

C

C

01100111

67

103

+G g

01000100

44

68

D

D

01101000

68

104

+H h

01000101

45

69

E

E

01101001

69

105

+I i

01000110

46

70

F

F

01101010

6A

106

+J j

01000111

47

71

G

G

01101011

6B

107

+K k

01001000

48

72

H

H

01101100

6C

108

+L l

01001001

49

73

I

I

01101101

6D

109

+M m

01001010

4A

74

J

J

01101110

6E

110

+N n

01001011

4B

75

K

K

01101111

6F

111

+O o

01001100

4C

76

L

L

01110000

70

112

+P p

01001101

4D

77

M

M

01110001

71

113

+Q q

01001110

4E

78

N

N

01110010

72

114

+R r

01001111

4F

79

O

O

01110011

73

115

+S s

01010000

50

80

P

P

01110100

74

116

+T t

01010001

51

81

Q

Q

01110101

75

117

+U u

01010010

52

82

R

R

01110110

76

118

+V v

01010011

53

83

S

S

01110111

77

119

+W w

01010100

54

84

T

T

01111000

78

120

+X x

01010101

55

85

U

U

01111001

79

121

+Y y

01010110

56

86

V

V

01111010

7A

122

+Z z

01010111

57

87

W

W

01111011

7B

123

%P

{

01011000

58

88

X

X

01111100

7C

124

%Q

|

01011001

59

89

Y

Y

01111101

7D

125

%R

}

01011010

5A

90

Z

Z

01111110

7E

126

01011011

5B

91

%K

[

01111111

7F

127

%S %T7

~ n8

01011100

5C

92

%L

\

01011101

5D

93

%M

]

01011110

5E

94

%N

^

01011111

5F

95

%O

_

01100000

60

96

%W

`

01100001

61

97

+A a

01100010

62

98

+B b

01100011

63

99

+C c

A-4

Notes: 0 1 2 3 4 5 6 7 8

Bit positions are 76543210 Hexadecimal value Decimal value Code 39 character(s) ASCII character SP is the SPACE character The Code 39 characters /P through /Y may be interchanged with the numbers 0 through 9. May be interchanged with %X or %Y or %Z n is the DELETE character

Page 193

ASCII Charts

A

ASCII Control Characters Control

Character Definitions

Control

Character Definitions

NUL

Null, or all zeros

DC1

Device Control 1 (XON)

SOH

Start of Heading

DC2

Device Control 2

STX

Start of Text

DC3

Device Control 3 (XOFF)

ETX

End of Text

DC4

Device Control 4

EOT

End of Transmission

NAK

Negative Acknowledge

ENQ

Enquiry

SYN

Synchronous Idle

ACK

Acknowledgment

ETB

End Transmission Block

BEL

Bell

CAN

Cancel

BS

Backspace

EM

End of Medium

HT

Horizontal Tab

SUB

Substitute

LF

Line Feed

ESC

Escape

VT

Vertical Tab

FS

File Separator

FF

Form Feed

GS

Group Separator

CR

Carriage Return

RS

Record Separator

SO

Shift Out

US

Unit Separator

SI

Shift In

SP

Space

DLE

Data Link Escape

DEL

Delete

A-5

Page 194

This page is a scan with no text; see it in the PDF.

Page 195

B Error Messages

Page 196

This page is a scan with no text; see it in the PDF.

Page 197

Error Messages

B

This appendix lists the IRL error messages in alphabetical order and by category.

Alphabetic List of IRL Error Messages Message

Meaning and Action

! Bad file id

Reference to an unopened file. You must open a file with the O command before you use the file in a program statement.

! Bad file open

Open command not at beginning of program. Place all O commands at the beginning of the program.

! Bad file rec

Reference to an invalid file record. Verify the size of the dimensioned file and any commands that reference the file.

! Call w/o quit

Subroutine call with no quit. All subroutines must end with the Q command.

! Dup file open

Duplicate open command. You can only open a file once. For example, you cannot have two files named B.

! Dup. label

Duplicate label. You can only use a label name once within a program.

! No file mem.

Insufficient memory to open file. The reader RAM is full. You need to free up some memory. Try opening a smaller data file. See your reader manual for memory limitations.

! No IRL Input

No input (A, K, N, U, V, or Y) command. An IRL program must contain at least one input command.

! No program

No IRL program exists for compilation. You entered a compile or run command on a reader that does not have an IRL program stored in memory.

! No such label

Reference to a nonexistent label. Verify the label name.

! Quit w/o call

Subroutine quit with no call. A Q command was encountered without a corresponding S command. A subroutine must be called with the S command and must end with a Q command.

! Symbol table

Insufficient memory for symbol in symbol table. You need to free up some memory. See your reader manual for memory limitations.

? #Reg

Numeric registers must be between 0 and 9. Verify the register number.

B-3

Page 198

IRL Programming Reference Manual

Message

Meaning and Action

? $Reg

String registers must be between 0 and 3 for IRL 2.X. String registers must be between 0 and 9 for IRL 4.X. Verify the register number.

? 3 Lengths ? 5 Lengths

Only 3 input lengths are allowed for IRL 2.X. Only 5 input lengths are allowed for IRL 4.X.

? Bit

Only 0 s and 1 s allowed. The B command accepts only 0 and 1 for data.

? Bit or X

Only 0 s, 1 s, and X s allowed. The F command accept only 0, 1, or X for data.

? End Chars

Unexpected characters found after the command. Verify the command syntax in Chapter 7, “IRL Command Descriptions.”

? File id

Illegal file identifier. Verify the filename. IRL only accepts 0 and A through Z as filenames.

? File rec

Illegal file record. Your program referenced a file record outside the range you defined in the O command.

? IRL Command

Unknown IRL Command. Verify the command syntax in Chapter 7, “IRL Command Descriptions.”

? IRL Syntax

Unrecognizable syntax for this IRL Command. Verify the command syntax in Chapter 7, “IRL Command Descriptions.”

? Missing (

Expected left parenthesis not found.

? Missing )

Expected right parenthesis not found.

? Missing +

Expected a concatenation operator (+).

? Missing ,

Expected comma not found. The command requires a comma before a parameter. Verify the command syntax in Chapter 7, “IRL Command Descriptions.”

? Missing <=>

Expected a conditional operator (<, =, >).

? Missing =

Expected an equals sign (=).

? Missing ]

Expected right bracket not found. The string length function uses this format: [$n]

? Missing label

Expected label not found. A G or S command refers to a label that does not exist.

? Missing op

Expected a numeric operator (+, -, *, /).

? Num recs

Number of record must be between 1 and 65,535.

? Number syntax

Illegal numeric syntax.

B-4

Page 199

Error Messages

Message

Meaning and Action

? Parameter

Unrecognized command parameter.

B

Verify the command syntax in Chapter 7, “IRL Command Descriptions.” ? Quote

Strings must be contained in quotes. Verify the command syntax in Chapter 7, “IRL Command Descriptions.” Some IRL v1.X commands did not require strings to be in quotation marks.

? Rec length

Record lengths must be between 1 and 128 or 1 and 250. IRL v2.X cannot use more than 128 characters per record. IRL v4.X cannot use more than 250 characters per record.

? Term char

Missing termination character. Verify the command syntax in Chapter 7, “IRL Command Descriptions.”

? Timeout

Timeouts must be between 1 and 6500.

? Wait

Waits must be between 1 and 65.

Command syntax

Illegal command syntax. Verify the command syntax in Chapter 7, “IRL Command Descriptions.”

Data in memory cannot download

IRL programs cannot be downloaded if data exists in any user-specified files or in the default file. Issue the Clear All Data Command and then try again.

Download failed; Protocol error

There are communication problems between the host and the reader.

Download failed; Syntax errors

The program to be downloaded contains syntax errors.

File not open

File has not been opened.

Check the protocol parameters and then try again. Correct the errors and try again. You must open a file before you refer to it. Verify the filename.

File rec. no.

Illegal file record number. Verify the size of the dimensioned file and any commands that reference the file. IRL data files have from 1 to 65,535 records.

Line number

Illegal line number. (IRL Editor/Monitor) Verify the program line number.

LRC data error

An LRC error was detected in the reader’s RAM. This is a fatal error.

LRC program error

An LRC error was detected in the IRL program. This is a fatal error.

Max. line no.

Maximum number of lines reached.

Mem almost full

The reader’s default file has less than 250 bytes of storage left. This is a warning message only.

Memory is full

Attempted to write more data to the default file than it can hold. This is a fatal error.

B-5

Page 200

IRL Programming Reference Manual

Message

Meaning and Action

Memory is full

No room to insert program data.

Missing equals

Missing equals sign.

Missing quote

Strings must be in quotes.

No IRL program

There is no IRL program to run. This is a fatal error. Download the program file and try to run it again.

Not a command

Unrecognized command. Verify the command syntax in Chapter 7, “IRL Command Descriptions.”

Not compiled

There is an IRL program in the reader that has not been compiled. This is a fatal error. Compile the program from the IRL Editor and then try to run it again.

Rec access err

Attempted to access a record beyond the end of the file. This error is not fatal, and the IRL command is ignored. Verify the dimensions of the file.

Reg. number

Illegal register number. Verify the number of registers with the table in Chapter 7, “IRL Command Descriptions.”

Register value

Illegal register value. Verify the limits on register values with the table in Chapter 7, “IRL Command Descriptions.”

Set file err

Attempted to set a file location beyond the end of the file. This error is nonfatal and the IRL command is ignored. Verify the dimensions of the file.

Stack overflow

Subroutine calls cannot be nested more than 20 times.

Stack underflow

Attempted to return from a subroutine when not in a subroutine. This is a fatal error. Verify that each Q command has a corresponding S command.

Unknown label

Label is not in symbol table. Verify the label name.

Write protect

Program is write protected. You cannot edit or delete a write-protected program file. See the E command in Chapter 7, “IRL Command Descriptions.”

B-6