The text of a manual · part 20 of 26
IRL Programming Reference Manual, pages 191 to 200
Pages 191 to 200 of 260
The original document is the PDF (666 KB). This is its text as extracted, unedited; tables and drawings read best in the PDF, and each page heading opens it at that page.
For the Intermec 9445, Intermec 9550, Intermec 9560 and Intermec 9512
Page 191
ASCII Charts
A
US ASCII Codes Binary0
Hex1
Dec2
C393
Char4
Binary0
Hex1
Dec2
C393
Char4
00000000
00
00
%U
NUL
00100000
20
32
SP
SP5
00000001
01
01
$A
SOH
00100001
21
33
/A
!
00000010
02
02
$B
STX
00100010
22
34
/B
"
00000011
03
03
$C
ETX
00100011
23
35
/C
#
00000100
04
04
$D
EOT
00100100
24
36
/D
$
00000101
05
05
$E
ENQ
00100101
25
37
/E
%
00000110
06
06
$F
ACK
00100110
26
38
/F
&
00000111
07
07
$G
BEL
00100111
27
39
/G
'
00001000
08
08
$H
BS
00101000
28
40
/H
(
00001001
09
09
$I
HT
00101001
29
41
/I
)
00001010
0A
10
$J
LF
00101010
2A
42
/J
*
00001011
0B
11
$K
VT
00101011
2B
43
/K
+
00001100
0C
12
$L
FF
00101100
2C
44
/L
,
00001101
0D
13
$M
CR
00101101
2D
45
/M
-
00001110
0E
14
$N
SO
00101110
2E
46
/N
.
00001111
0F
15
$O
SI
00101111
2F
47
/
00010000
10
16
$P
DLE
00110000
30
48
/O /P6
0
00010001
11
17
$Q
DC1
00110001
31
49
/Q
1
00010010
12
18
$R
DC2
00110010
32
50
/R
2
00010011
13
19
$S
DC3
00110011
33
51
/S
3
00010100
14
20
$T
DC4
00110100
34
52
/T
4
00010101
15
21
$U
NAK
00110101
35
53
/U
5
00010110
16
22
$V
SYN
00110110
36
54
/V
6
00010111
17
23
$W
ETB
00110111
37
55
/W
7
00011000
18
24
$X
CAN
00111000
38
56
/X
8
00011001
19
25
$Y
EM
00111001
39
57
/Y
9
00011010
1A
26
$Z
SUB
00111010
3A
58
/Z
:
00011011
1B
27
%A
ESC
00111011
3B
59
%F
;
00011100
1C
28
%B
FS
00111100
3C
60
%G
<
00011101
1D
29
%C
GS
00111101
3D
61
%H
=
00011110
1E
30
%D
RS
00111111
3E
62
%I
>
00011111
1F
31
%E
US
00111111
3F
63
%J
?
A-3
Page 192
IRL Programming Reference Manual
Binary0
Hex1
Dec2
C393
Char4
Binary0
Hex1
Dec2
C393
Char4
01000000
40
64
%V
@
01100100
64
100
+D d
01000001
41
65
A
A
01100101
65
101
+E e
01000010
42
66
B
B
01100110
66
102
+F f
01000011
43
67
C
C
01100111
67
103
+G g
01000100
44
68
D
D
01101000
68
104
+H h
01000101
45
69
E
E
01101001
69
105
+I i
01000110
46
70
F
F
01101010
6A
106
+J j
01000111
47
71
G
G
01101011
6B
107
+K k
01001000
48
72
H
H
01101100
6C
108
+L l
01001001
49
73
I
I
01101101
6D
109
+M m
01001010
4A
74
J
J
01101110
6E
110
+N n
01001011
4B
75
K
K
01101111
6F
111
+O o
01001100
4C
76
L
L
01110000
70
112
+P p
01001101
4D
77
M
M
01110001
71
113
+Q q
01001110
4E
78
N
N
01110010
72
114
+R r
01001111
4F
79
O
O
01110011
73
115
+S s
01010000
50
80
P
P
01110100
74
116
+T t
01010001
51
81
Q
Q
01110101
75
117
+U u
01010010
52
82
R
R
01110110
76
118
+V v
01010011
53
83
S
S
01110111
77
119
+W w
01010100
54
84
T
T
01111000
78
120
+X x
01010101
55
85
U
U
01111001
79
121
+Y y
01010110
56
86
V
V
01111010
7A
122
+Z z
01010111
57
87
W
W
01111011
7B
123
%P
{
01011000
58
88
X
X
01111100
7C
124
%Q
|
01011001
59
89
Y
Y
01111101
7D
125
%R
}
01011010
5A
90
Z
Z
01111110
7E
126
01011011
5B
91
%K
[
01111111
7F
127
%S %T7
~ n8
01011100
5C
92
%L
\
01011101
5D
93
%M
]
01011110
5E
94
%N
^
01011111
5F
95
%O
_
01100000
60
96
%W
`
01100001
61
97
+A a
01100010
62
98
+B b
01100011
63
99
+C c
A-4
Notes: 0 1 2 3 4 5 6 7 8
Bit positions are 76543210 Hexadecimal value Decimal value Code 39 character(s) ASCII character SP is the SPACE character The Code 39 characters /P through /Y may be interchanged with the numbers 0 through 9. May be interchanged with %X or %Y or %Z n is the DELETE character
Page 193
ASCII Charts
A
ASCII Control Characters Control
Character Definitions
Control
Character Definitions
NUL
Null, or all zeros
DC1
Device Control 1 (XON)
SOH
Start of Heading
DC2
Device Control 2
STX
Start of Text
DC3
Device Control 3 (XOFF)
ETX
End of Text
DC4
Device Control 4
EOT
End of Transmission
NAK
Negative Acknowledge
ENQ
Enquiry
SYN
Synchronous Idle
ACK
Acknowledgment
ETB
End Transmission Block
BEL
Bell
CAN
Cancel
BS
Backspace
EM
End of Medium
HT
Horizontal Tab
SUB
Substitute
LF
Line Feed
ESC
Escape
VT
Vertical Tab
FS
File Separator
FF
Form Feed
GS
Group Separator
CR
Carriage Return
RS
Record Separator
SO
Shift Out
US
Unit Separator
SI
Shift In
SP
Space
DLE
Data Link Escape
DEL
Delete
A-5
Page 194
Page 195
B Error Messages
Page 196
Page 197
Error Messages
B
This appendix lists the IRL error messages in alphabetical order and by category.
Alphabetic List of IRL Error Messages Message
Meaning and Action
! Bad file id
Reference to an unopened file. You must open a file with the O command before you use the file in a program statement.
! Bad file open
Open command not at beginning of program. Place all O commands at the beginning of the program.
! Bad file rec
Reference to an invalid file record. Verify the size of the dimensioned file and any commands that reference the file.
! Call w/o quit
Subroutine call with no quit. All subroutines must end with the Q command.
! Dup file open
Duplicate open command. You can only open a file once. For example, you cannot have two files named B.
! Dup. label
Duplicate label. You can only use a label name once within a program.
! No file mem.
Insufficient memory to open file. The reader RAM is full. You need to free up some memory. Try opening a smaller data file. See your reader manual for memory limitations.
! No IRL Input
No input (A, K, N, U, V, or Y) command. An IRL program must contain at least one input command.
! No program
No IRL program exists for compilation. You entered a compile or run command on a reader that does not have an IRL program stored in memory.
! No such label
Reference to a nonexistent label. Verify the label name.
! Quit w/o call
Subroutine quit with no call. A Q command was encountered without a corresponding S command. A subroutine must be called with the S command and must end with a Q command.
! Symbol table
Insufficient memory for symbol in symbol table. You need to free up some memory. See your reader manual for memory limitations.
? #Reg
Numeric registers must be between 0 and 9. Verify the register number.
B-3
Page 198
IRL Programming Reference Manual
Message
Meaning and Action
? $Reg
String registers must be between 0 and 3 for IRL 2.X. String registers must be between 0 and 9 for IRL 4.X. Verify the register number.
? 3 Lengths ? 5 Lengths
Only 3 input lengths are allowed for IRL 2.X. Only 5 input lengths are allowed for IRL 4.X.
? Bit
Only 0 s and 1 s allowed. The B command accepts only 0 and 1 for data.
? Bit or X
Only 0 s, 1 s, and X s allowed. The F command accept only 0, 1, or X for data.
? End Chars
Unexpected characters found after the command. Verify the command syntax in Chapter 7, “IRL Command Descriptions.”
? File id
Illegal file identifier. Verify the filename. IRL only accepts 0 and A through Z as filenames.
? File rec
Illegal file record. Your program referenced a file record outside the range you defined in the O command.
? IRL Command
Unknown IRL Command. Verify the command syntax in Chapter 7, “IRL Command Descriptions.”
? IRL Syntax
Unrecognizable syntax for this IRL Command. Verify the command syntax in Chapter 7, “IRL Command Descriptions.”
? Missing (
Expected left parenthesis not found.
? Missing )
Expected right parenthesis not found.
? Missing +
Expected a concatenation operator (+).
? Missing ,
Expected comma not found. The command requires a comma before a parameter. Verify the command syntax in Chapter 7, “IRL Command Descriptions.”
? Missing <=>
Expected a conditional operator (<, =, >).
? Missing =
Expected an equals sign (=).
? Missing ]
Expected right bracket not found. The string length function uses this format: [$n]
? Missing label
Expected label not found. A G or S command refers to a label that does not exist.
? Missing op
Expected a numeric operator (+, -, *, /).
? Num recs
Number of record must be between 1 and 65,535.
? Number syntax
Illegal numeric syntax.
B-4
Page 199
Error Messages
Message
Meaning and Action
? Parameter
Unrecognized command parameter.
B
Verify the command syntax in Chapter 7, “IRL Command Descriptions.” ? Quote
Strings must be contained in quotes. Verify the command syntax in Chapter 7, “IRL Command Descriptions.” Some IRL v1.X commands did not require strings to be in quotation marks.
? Rec length
Record lengths must be between 1 and 128 or 1 and 250. IRL v2.X cannot use more than 128 characters per record. IRL v4.X cannot use more than 250 characters per record.
? Term char
Missing termination character. Verify the command syntax in Chapter 7, “IRL Command Descriptions.”
? Timeout
Timeouts must be between 1 and 6500.
? Wait
Waits must be between 1 and 65.
Command syntax
Illegal command syntax. Verify the command syntax in Chapter 7, “IRL Command Descriptions.”
Data in memory cannot download
IRL programs cannot be downloaded if data exists in any user-specified files or in the default file. Issue the Clear All Data Command and then try again.
Download failed; Protocol error
There are communication problems between the host and the reader.
Download failed; Syntax errors
The program to be downloaded contains syntax errors.
File not open
File has not been opened.
Check the protocol parameters and then try again. Correct the errors and try again. You must open a file before you refer to it. Verify the filename.
File rec. no.
Illegal file record number. Verify the size of the dimensioned file and any commands that reference the file. IRL data files have from 1 to 65,535 records.
Line number
Illegal line number. (IRL Editor/Monitor) Verify the program line number.
LRC data error
An LRC error was detected in the reader’s RAM. This is a fatal error.
LRC program error
An LRC error was detected in the IRL program. This is a fatal error.
Max. line no.
Maximum number of lines reached.
Mem almost full
The reader’s default file has less than 250 bytes of storage left. This is a warning message only.
Memory is full
Attempted to write more data to the default file than it can hold. This is a fatal error.
B-5
Page 200
IRL Programming Reference Manual
Message
Meaning and Action
Memory is full
No room to insert program data.
Missing equals
Missing equals sign.
Missing quote
Strings must be in quotes.
No IRL program
There is no IRL program to run. This is a fatal error. Download the program file and try to run it again.
Not a command
Unrecognized command. Verify the command syntax in Chapter 7, “IRL Command Descriptions.”
Not compiled
There is an IRL program in the reader that has not been compiled. This is a fatal error. Compile the program from the IRL Editor and then try to run it again.
Rec access err
Attempted to access a record beyond the end of the file. This error is not fatal, and the IRL command is ignored. Verify the dimensions of the file.
Reg. number
Illegal register number. Verify the number of registers with the table in Chapter 7, “IRL Command Descriptions.”
Register value
Illegal register value. Verify the limits on register values with the table in Chapter 7, “IRL Command Descriptions.”
Set file err
Attempted to set a file location beyond the end of the file. This error is nonfatal and the IRL command is ignored. Verify the dimensions of the file.
Stack overflow
Subroutine calls cannot be nested more than 20 times.
Stack underflow
Attempted to return from a subroutine when not in a subroutine. This is a fatal error. Verify that each Q command has a corresponding S command.
Unknown label
Label is not in symbol table. Verify the label name.
Write protect
Program is write protected. You cannot edit or delete a write-protected program file. See the E command in Chapter 7, “IRL Command Descriptions.”
B-6