Browse
(440) 299-7778
Menu
(440) 299-7778
One-year parts and labor warranty30-day money-back guaranteeEnglishEspañolContact

The text of a manual · part 9 of 16

680x Series Portable Printers Technical Reference Manual: Section 4: Operation, pages 79 to 88

Pages 79 to 88 of 146, from 680x Series Portable Printers Technical Reference Manual

The original document is the PDF (15 MB). This is its text as extracted, unedited; tables and drawings read best in the PDF, and each page heading opens it at that page.

For the Intermec 6804

Page 79

Operation

SECTION 4

QSTOPnnn

Qstop Global Option

Format: QSTOPnnn (1 < nnn < 65000) (6805a, 6806, and 6804) Function: Stop nnn dot lines after sensing “Q” mark. After the mark has been found, the paper advances for “nnn” dot lines and stops (even if the image is not yet complete.) If, however, there is no “Q” mark on the paper, the printer continues its search. See also the “STOP” option for use as a safeguard. Example: {PRINT,QSTOP500:@10,30:MF107|Hi world| } " NOTE:

The “Q” must be positioned so that it does not sit under the sensor when the paper is properly aligned. See Appendix A, for more on the Qmark.

ROT270

ROT270 Global Option

Format: ROT270 Function: Will rotate image so that the left--hand edge of the landscape image prints first. Example: {PRINT,ROT270:@10,30:MF107|Hi world| } STOP nnn

Stop Global Option

Format: STOP nnn

( 1 < nnn < 65000)

Function: Use the STOP option to advance the paper to the proper point for tearing. This options stops the paper “nnn” dot lines after the beginning of the label or receipt. The data “nnn” sent after the STOP option specifies the total number of dot lines high for this print image. For example, for the 680x series, which have a 203 DPI mechanism, specifying “STOP 500” will give a 2.5” total height image from the top of the paper to where it has stopped under the print head. The STOP option can be used with the QSTOP option. Set the STOP to stop the printing just after the stop using the QSTOP option. This way, the paper will always stop adIntermec Portable Printers Technical Reference Manual

4-31

Page 80

Operation

SECTION 4 vancing whether paper with “Q” marks is loaded, or regular paper is loaded. Example:{PRINT,STOP500,QSTOP125: @10,30:MF107|Hi world| } In this example, the paper will stop advancing when it has advanced 500 dot lines, or 125 dot lines after the “Q” mark has been detected, whichever occurs first. {Print, Global options:@row,column:Name,Field Options|data|}

Font Names To print text, you must specify the name of the font for the text to be printed. Each font has a five--character name. This is only a partial list. For the entire list of available fonts, see Appendix C. Table 4-6 Printing Text Font Name Descriptions Name

CPI

Description

MF055

5.5

96 chars large block (26 chars for lower case, 26 chars for upper case, plus symbols, etc.)

MF072

7.2

95 chars large block

MF102

10.2

223 chars medium block bold

MF107

10.7

96 chars block bold

MF185

18.5

96 chars block normal

MF204

20.4

224 chars block normal (default font for 6805a, 6806, and 6804 printers).

6804DM Printer Only IM5X7 22.1 (default) 4-32

96 characters for impact 5 x 7

Intermec Portable Printers Technical Reference Manual

Page 81

Operation

SECTION 4

Table 4-6 (continued) Printing Text Font Name Descriptions Name

CPI

Description

IM5X8

22.1

96 characters for impact 5 x 8

MF226

22.6

96 chars small block

Font Field Options These options are used to heighten or widen the font. Table 4-7 Font Field Option Descriptions

" NOTE:

Field Option Abbr.

Description

HMULTn

HMn

Widens text; 1 < n < 255.

VMULTn

Vn

Heightens text; 1 < n < 255.

To compare the fonts, run the demo program and print the samples. See Chapter 2, Quick Demo.

Bar Code Names Table 4-8 Bar Code Description and Data Requirements Name

Description

Requirements for Data

BC39N

Code 39 2:1 ratio

Can use these characters in the data field: Space $ % + . / 0--9 A -- Z. Auto inserts leading and trailing “*”

BC39W

Code 39 3:1 ratio

Can use same characters as above.

COBAR

Codabar

0--9 -- $ : / . + a b c d, user must send leading and trailing guard bar a--d

I2of5

Int. 2 of 5 2.5:1 ratio

0--9 (digits only, must be even. Controller will insert leading zero to assure an even number of digits). Intermec Portable Printers Technical Reference Manual

4-33

Page 82

Operation

SECTION 4

Table 4-8 (continued) Bar Code Description and Data Requirements Name

Description

Requirements for Data

BCI25

Int. 2 of 5 2:1 ratio

0--9 (digits only, must be even. Controller will insert leading zero to assure an even number of digits).

BC128

Code 128

Automatically selects Codes A -- C, for the shortest bar code. Allows all ASCII characters.

EN128

EAN--128

Uses Codes C, for the shortest bar code. Allows all ASCII characters.

UPC--A

UPC--A

0--9 (must have 11 digits or error, controller calculates check digit).

EAN08

EAN--8

0--9 (must have 7 digits or error, controller calculates check digit).

EAN13

EAN--13

0--9 (must have 12 digits or error, controller calculates check digit).

PD417

PDF--417

See Notes on the use of PDF--417.

Bar Code Field Options Table 4-9 Bar Code Field Option Descriptions Field Option Abbr.

Description

HIGHn

Hn

Changes height of bar code in 5 dot inch intervals; default is 5 dots; 1 < n < 255.

WIDEn

Wn

Width multiplier of bar code; default is 1; W = 2 is twice as wide (1/2 density) as W = 1; 1 < n < 255.

Notes on the use of PDF-417 Use PDF--417 the same as any other bar code: 1. After entering Easy Print using ESC+EZ, select the barcode using the name “PD417”. 4-34

Intermec Portable Printers Technical Reference Manual

Page 83

SECTION 4

Operation

2. Enter data between two ‘|’. If the data is long, DO NOT put CR/LF in data unless you want the CR/LF to be in the bar code. PDF--417 has several field parameters that may be specified: 1. COLUMNS will specify the number of columns of DATA printed in each row of the bar code. If not specified, the default value of 2 DATA columns is used. The actual COLUMNS used is 4 greater then DATA COLUMNS. (2 for GARD COLUMNS and 2 for ROW indicator COLUMNS). 2. SECURITY specifies the level of error detection and correction codes, from 1 through 8. If not specified, the default value for the number of data characters to be printed is used: " 1--40 characters level 2 " 40--160 characters level 3 " 161--320 characters level 4 " 321--863 characters level 5 3. YDIM specifies the height of each element, in units of .005 inches. Default is 1 4. WDIM specifies the width of each element, in units of .005 inches. Default is 1 PDF--417 symbols contains: 1. A maximum of 1848 text characters (fewer if mixed with arbitrary bytes) 2. A minimum of 3 rows and a maximum of 30 rows 3. A minimum of 1 column and a maximum of 30 columns 4. Error detection and correction characters vary with different security levels: " Level 1 adds 4 codewords " Level 2 adds 8 code words Intermec Portable Printers Technical Reference Manual

4-35

Page 84

Operation

EXAMPLE:

SECTION 4

"

Level 3 adds 16 code words

"

Level 4 adds 32 code words

"

Level 5 adds 64 code words

"

Level 6 adds 128 code words

"

Level 7 adds 256 code words

"

Level 8 adds 512 code words

{PRINT:@75,10:PD417,YDIM 6,XDIM 2,COLUMNS 2, SECURITY 3|ABCDEFGHIJKL|}

Will print a PDF--417 bar code containing ABCDEFGHIJKL with each element .010” wide and .030” high, with each row containing 2 data bytes and using a error detection and correction level of 3, which adds 16 error correction code words to the bar code. You can print any characters using the PDF--417. It is optimized for the most common printing of a mixture of numbers, text, and control characters.

Graphic Names Function: Print a stored graphic, e.g. stored under the name “alogo.” EXAMPLE 1:

{PRINT: @10,30:ALOGO|}

EXAMPLE 2:

{PRINT:@10,30:ALOGO,HMULT2, VMULT2|}

Explanation: Example 1 prints whatever logo has been stored under the five--character name, “ALOGO.” (See Chapter 3 on how to use the “Graphics” button in the Configuration Program to store a graphic automatically. Example 2 above makes the logo twice as big as it would be otherwise. 4-36

Intermec Portable Printers Technical Reference Manual

Page 85

Operation

SECTION 4

Graphic Field Options These options are used to widen or heighten the graphic. Table 4-10 Graphic Field Option Descriptions

" NOTE:

Field Option Abbr.

Description

HMULTn

HMn

Multiplies width of graphic by “n”

VMULTn

VMn

Multiplies height of graphic by “n”

See Chapter 3, Graphics section, for storing graphics automatically before you print.

Line Names Format 1:

Hline, length nnn, thick n

Format 2:

Vline, length nnn, thick n

Function: Horizontal and vertical lines can be drawn around text or graphics. EXAMPLE 1:

{PRINT: @60,30:HLINE, length 200, thick 2|}

EXAMPLE 2:

{PRINT:@60,30:VLINE, length 50, thick2|}

Explanation: Example 1 prints a horizontal line 200 dot lines long, and two dot lines thick. Example 2 prints a vertical line 50 dot lines long, and 2 dot lines thick. There is only a single vertical bar “|” because there is no data to enclose. Table 4-11 Line Names Option Descriptions Abbr

Name

Description

T

HLINE

Horizontal line

V

VLINE

Vertical line

Intermec Portable Printers Technical Reference Manual

4-37

Page 86

Operation

SECTION 4

Table 4-11 (continued) Line Names Option Descriptions Abbr

Name

Description

L

Lengthnnn Set line length

T

Thicknnn

Set line thickness

Card Reader Commands Operational Commands All operational commands for the magnetic/smart card reader peripheral are IMMEDIATE commands, taking the form of Easy Print commands (bracketed by “{“ and “}”) and preceded by the ESC (1Bh) character. Responses vary by command. All operational commands are two characters, followed by: ! command complete, no data is expected in response ? command complete, response with data expected : data for peripheral follows In addition, the reader has configuration options which can be semi--“permanently” set in Flash for LED usage, Magnetic Stripe and Smart Card reader. Format for these configuration commands follows the self--writing three character configuration commands (similar to IR related configuration commands). In all cases, the printer will respond with either a NAK (N<crc>}, or a WACK (W<crc>) indicating the printer is busy writing to flash followed by an ACK (A<crc>). The CRC is the common CRC--16. 4-38

Intermec Portable Printers Technical Reference Manual

Page 87

Operation

SECTION 4

General Reader Operational Commands The card reader has two LEDs, red and green that may be used to give a visual status to the user for either magnetic cards or smart cards. In addition, the printer can be polled for general card reader status as well as the current state of the LEDs. Semicolons separate elements of the returned status: Command: {RS?} Status – returns power, card inserted, and LED status as follows: P:0/1 for smart card (ICC) power off or on " S:0/1 for card not seated or seated " B:0/1 for button currently connected to reader " G:0/1/F for Green Led off or on or flashing " R:0/1/F for Red Led off or on or flashing " Example Response – no button reader {RS!P:0;S:1;G:F;R:0}indicating ICC power off, card is seated and green led is flashing " Example Response – with button reader {RS!P:0;S:0;B:1;G:0;R:0} indicating ICC and LEDs off, no card seated, button in contact Command: {RG:data} Controls Green Led – requires 1 data byte. "

Response: {RG!} if the command was received (for any data sent). Command: {RR:data} Controls Red Led -- requires 1 Data byte. Response: {RR!} if the command was received (for any data sent). RG/RR data:

0 (zero) – Turn LED off 1 (one) – Turn LED on F (flash) – Begin flashing LED

Intermec Portable Printers Technical Reference Manual

4-39

Page 88

Operation

SECTION 4

General Reader Configuration Commands The red and green LEDs and buzzer can be configured to be under host control, or the printer ’s control. The printer can control the LEDs only if EITHER the MAG card read is enabled, OR the Smart Card is enabled, but not both. If the LEDs are configured to be under host control, the MG and MR commands will override the printer ’s current use of the LED: Command: {CCR:data} Reader LED and BEEPER configuration – requires data CCR data: HOST – LEDs and BEEPER are under host control AUTO – LEDs and BEEPER are under reader ’s control: If MAG card enabled and ICC Smart Card disabled: Flashing Green – card inserted " Solid Green (timed) + 2 short beeps – good read " Solid Red (timed) + 1 long beep – bad read If ICC Smart Card enabled and MAG card disabled "

" " "

Flashing Green – card inserted Solid Red – card inserted and ICC power ON Solid Green (timed) – card inserted and ICC power turned OFF

Magnetic Card Operational Commands The magnetic card reader is always operating in the background if it is enabled. Magnetic card data is read when the card is inserted, removed, or both (default is read on removal only). That data read is stored in the printer until the data is zeroed or the printer falls asleep. Temporary 4-40

Intermec Portable Printers Technical Reference Manual