Browse
(440) 299-7778
Menu
(440) 299-7778
One-year parts and labor warranty30-day money-back guaranteeEnglishEspañolContact

The text of a manual · part 14 of 28

PEN*KEY 6400 Computer Programmer's Reference Guide: Section 4: Communications and Device Support, pages 103 to 110

Pages 103 to 110 of 234, from PEN*KEY 6400 Computer Programmer's Reference Guide

The original document is the PDF (1.4 MB). This is its text as extracted, unedited; tables and drawings read best in the PDF, and each page heading opens it at that page.

For the Intermec 6400

Page 103

SECTION 4

Communications and Device Support

AH=

AL=

BL=

Display Set Display Mode . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 00h Turn Display On . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 12h Turn Display Off . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 12h

00h 01h

36h 36h

Fonts Return Pointer to Current Display Parameter Packet and Font Information . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 12h Load User Font . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 14h

00h

INT 10h Display Services (continued)

FBh

Graphics Write Graphics Dot . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 0Ch Read Graphics Dot . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 0Dh Page Set Active Display Page . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 05h Size Set Physical Display Size . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 12h Return Physical Display Size . . . . . . . . . . . . . . . . . . . . . . . . . . . . 12h

FAh FDh

Scrolling Scroll Window Up (active page) . . . . . . . . . . . . . . . . . . . . . . . . . . 06h Scroll Window Down (active page) . . . . . . . . . . . . . . . . . . . . . . . 07h Viewport Set Viewport position to Lower-Left Corner . . . . . . . . . . . . . . . Set Viewport position to Upper-Left Corner . . . . . . . . . . . . . . . Set Viewport to Follow Cursor . . . . . . . . . . . . . . . . . . . . . . . . . . . Get Current Viewport Location . . . . . . . . . . . . . . . . . . . . . . . . . . Lock Viewport . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Unlock Viewport . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

12h 12h 12h 12h 12h 12h

00h 01h 02h 05h 06h 07h

F6h F6h F6h F6h F6h F6h

Miscellaneous Read Current Video Mode . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 0Fh Draw Pixel Map . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . F0h Refresh the Screen . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . FFh

PEN*KEYR 6400 Programmer’s Reference Guide

4-25

Page 104

Communications and Device Support

SECTION 4

Memory The 6400 Computer uses two types of memory: Main memory DRAM and flash memory. The main memory is protected by the backup battery during low or dead main battery conditions.

Creating RAM and Flash Disks Refer to the Reprogramming Flash Memory paragraph, in the Getting Started section of this publication for a detailed description.

Flash File System The flash memory stores files for BIOS and DOS. The software stored in flash is copied into DRAM during execution of that software. Flash memory could also store information during operation. This information stored in flash memory is retained, even if all of the power sources have been depleted.

RAM Disk Refer to The RAM Drive paragraph, under the Development Resources paragraph, in the Getting Started section of this publication, for a detailed description.

Upper Memory Provider: ELANUMP.SYS ELANUMP.SYS is an upper memory provider. It supports the minimal set of XMS function calls required to provide upper memory to DOS when you have a “DOS=UMB” statement in the CONFIG.SYS file. The Upper Memory Provider (UMP) supplies all upper memory block elements, in the range of C000h–EFFFh, on a 6000 Series Computer. You can use it in conjunction with HIMEM.SYS, or as a stand-alone program. The UMP does not support the XMS calls that deal with the deallocation or reallocation of upper memory blocks. The UMP is similar to EMM386.EXE for loading devices into high memory area. Unlike EMM386 with the NOEMS switch, the UMP supplies DOS with memory from the first megabyte of the system memory. This is memory that would otherwise be available for use as shadow RAM. EMM386 does not know how to program the memory controller to access this memory, so it uses some of the extended memory to emulate upper memory. The UMP is also much smaller and simpler than EMM386. Since EMM386 is a virtual mode system extension, it also slows down processing somewhat as it handles special exception interrupts that are required when providing virtual memory to DOS. If you want upper memory, and do not need expanded memory, the UMP uses less system memory; therefore making more memory available to the system. 4-26

PEN*KEYR 6400 Programmer’s Reference Guide

Page 105

SECTION 4

Communications and Device Support

Option ROM blocks are automatically scanned for, and reserved (that is, excluded from being used). A single command line switch is provided to force the UMP to reserve memory block elements, other than those with option ROM signatures in them. The syntax for this switch is: /X=aaaa[,aaaa] where the addresses specified are hexadecimal starting addresses for each block of memory to be reserved. The complete list of the blocks available in hardware is C400, C800, CC00, D800, DC00, and E000. Note that the last block is 32KB in size instead of 16 KB. This is a hardware constraint defined by the memory controller in the processor chipset. The 6400 Computer provides upper memory (C400–CFFF, D800–E3FF) and HMA memory, using both HIMEM.SYS and ELANUMP.SYS: DEVICE=HIMEM.SYS DOS=HIGH DEVICE=ELANUMP.SYS /X=C000, D000, D400, E400, E800, EC00 DOS=UMB DEVICEHIGH=...

Where: " " "

C000 is for the Proxim 2.4GHz radio card. D000, D400 are for the Flash File System. E400, E800, and EC00 are for DOS.

PEN*KEYR 6400 Programmer’s Reference Guide

4-27

Page 106

Communications and Device Support

SECTION 4

Battery The 6400 Computer contains a rechargeable lithium ion battery pack for the main power source and a nickel-metal hydride battery for the backup power source. " NOTE:

For detailed information on DOSGAS.EXE, charging, and annunciator display, refer to the Supported DOS Applications section.

Battery Management Charge Rate Before using a new battery pack, it needs to be charged for twelve hours in a dock, or an AC power cube and communications adapter. The charge rate should average about 1 Ampere. The normal charge time, from empty to full, for the main battery pack is 1.5 hours for a standard 2 cell pack, and 3 hours for a 4 cell pack. The battery packs are rated for 500 full charge and discharge cycles, after which you can expect only 50 percent of their original capacity. The main and backup batteries do not charge below 0 °C (32 °F) and above 40 °C (104 °F). The life of each cell in the battery is reduced when running in cold temperatures.

Discharge Rate The maximum discharge rate is 2 Amperes. A fully charged battery pack, left outside of a charger or your 6400 Computer, self-discharges in about 20 days.

Capacity You can check to see if the batteries need to be replaced, by touching the top two contacts on the battery with your fingers. The capacity, or charge level, remaining in the battery is indicated by the number of LEDs that are lighted, as follows: " One LED = 21 to 25 percent charge level " Two LEDs = 26 to 50 percent charge level " Three LEDs = 51 to 75 percent charge level " Four LEDs = 76 to 100 percent charge level The 960 mAH lithium ion (LiION) battery pack has been replaced by the 1350 mAH lithium ion battery pack, PN 318-001-001.

Battery Status The LiION battery pack sends status packets through I/O addresses 278–27Fh, which are captured by ELANAPM.EXE and DOSGAS.EXE. DOSGAS then displays the capacity on the screen. ELANAPM forwards the battery capacity and number of charge cycles to the APM 1.1 functions that can be called by your application and by NORDOSPM.EXE. 4-28

PEN*KEYR 6400 Programmer’s Reference Guide

Page 107

SECTION 4

Communications and Device Support

Annunciators The battery annunciators indicate the level of the main battery. Table 4-5 Low Battery Indications

" NOTE:

Low Battery Level

% Capacity

Icons

0

1 2 3

76 - 100% 51 - 75% 26 - 50% 21 - 25% 16 - 20% 11 - 15% 6 - 10%

BBBB BBB BB B LLLL LLL LL

4

0 - 5%

L

Beeps

Three beeps on 10% Three beeps on 7% One 5 second beep on 5%

The Bs in the preceding table are actually displayed on the 6400 Computer as small battery icons.

When the capacity reaches 20%, the single annunciator icon changes to four Ls, as described in the preceding chart. When unit is charging, the annunciator icons change to Cs, as shown below. Table 4-6 Charging Indications

" NOTE:

% Capacity

Icons

25% - 0% 50% - 26% 75% - 51% 100% - 76%

C CC CCC CCCC

There may be a delay of one minute for the icons to update when the battery pack is replaced.

Terminal Emulations If there is no main battery pack, or the charge level in the pack cannot be determined, only a single ‘C’ is displayed. Also note that when the unit first boots up, or after a Suspend/Resume, it displays a single ‘C’, until the unit obtains valid information from the battery pack. After 10–50 seconds, if valid information is received the number of Cs may increase which reflects the charge level of the battery pack. External Power Any time external power is supplied to the 6400 Computer, the icons randomly switch between Cs and battery icons. Internal Power The standard annunciators are displayed whenever the unit is not powered by an external power source. PEN*KEYR 6400 Programmer’s Reference Guide

4-29

Page 108

SECTION 4

Communications and Device Support

Charging Your Battery Pack The battery pack can be charged in your 6400 computer, or in a charger. When you remove fully charged batteries from the charger, it is best to place it directly into a 6400 computer. The following devices can be used to charge battery packs: " Single pack charger " Multipack charger " Single dock " Multidock " Vehicle dock " Communication adapter with AC power cube

Troubleshooting Battery Charger LED and Error Codes When your battery pack is placed in either a multipack or a single pack charger, the LEDs on the charger indicate the battery pack charging status. This indicates the charge capacity remaining in the battery. The battery pack charger cups and docs have a tri-color LED. A constant red LED indicates the battery is charging. A constant green LED indicates the battery pack is fully charged. If one of the following conditions exist, take the action listed: Indication

Meaning

No LEDs lit

No power or no connection Reinsert into charger, Turn charger power on, Check for bad charger A bad connection: Remove and reinsert battery pack into charger A faulty battery: Replace it A more serious charging See chart below or product error:

A combination of blinking LEDs

Action

The following chart shows a list of serious error codes and possible solutions. If the battery cannot be successfully charged, one or more LEDs flash. By observing the sequence of colors, use the table below (and the Possible Solutions on page 4-31) to determine the error code: Table 4-7 Battery Charger LED Error Codes

Color Sequence Orange Red Orange Red Red Red Orange Orange 4-30

Orange Orange Red Red Red Orange Orange Red

Description Orange Red Red Red Orange Orange Red Orange

Off Off Off Off Off Off Off Off

PEN*KEYR 6400 Programmer’s Reference Guide

Battery pack in “fault” state (see 1 and 2 below) No packets in charger, after 90 seconds (see 1 below) Checksum error (see 1 below) Upper cell voltage fault (see 1 and 3 below) Lower cell voltage fault (see 1 and 3 below) Received five sequential bad packets (see 1 below) Wrong type of battery (see 4 below) Wrong type of battery (see 1 below)

Page 109

SECTION 4

Communications and Device Support

Charger Problems and Solutions Perform the following check, if one of the states above referenced note 1: 1. To isolate the issue to the ‘faulting’ battery pack, place it into a 6400 computer and operate the computer for a few minutes. Then try the battery pack in different charger cups to see if the LED indicators still create this fault. If this fault continues to show up, send the battery pack to your service center. Perform the following check, if one of the states above referenced note 2: 2. This issue could be caused by a bad charger cup or a bad 6400 computer. Insert different batteries into this same charger cup. If the cup produces this same fault state (in the other batteries), then this cup on the charger is bad. To get the battery back into a good state, put it back into a 6400 computer, and operate it for a few minutes. Then place the battery pack on a good charger cup. Perform the following check, if one of the states above referenced note 3: 3. Leave the battery pack in the charger for i minimum of 16 hours. If the error condition still exists, send the battery pack to your service center. Perform the following check, if one of the states above referenced note 4: 4. Remove the battery pack and replace with the appropriate battery.

Common Problems and Solutions Symptom

Possible Solution

A fully charged battery pack is inserted into the 6400 computer. The unit powers down. The battery pack appears dead (no LEDs lit on gas gauge).

Leave the same battery pack in the 6400 computer for at least thirty minutes. Then replace the battery pack with a fully charged battery. Place the original battery pack into an external charger.

The gas gauge on the display does not match the gas gauge on the battery pack.

Wait: It takes up to one minute to update the gas gauge on the display.

When a fully charged battery pack is inserted into the 6400 computer, after a weekend, it does not last the normal full length of time.

You should always keep a battery pack in the 6400 computer (while not in use), especially over a weekend.

The 6400 computer performed a reboot when the battery pack is changed.

♦ Always suspend the 6400 computer (press the I/O button) before you change the battery.

♦ The backup battery may have completely drained.

To overcome this, charge the backup battery.

♦ If the problem persists, send the unit into your service center.

Different colors of charge LEDs blink when a battery is inserted into the charger cup.

There is a fault state occurring , either in the battery pack or the charger. Refer to Possible Solutions, above, to isolate the issue.

PEN*KEYR 6400 Programmer’s Reference Guide

4-31

Page 110

Communications and Device Support

SECTION 4

Beeper The computer has a beeper that emits a sound under different conditions. Key Click is the sound that is made when a key is pressed. Error Tone is the sound that is made when an error occurs (for example, pressing an invalid key). When you make a good scan, a sound is also heard.

Adjusting Volume, Length, and Frequency The setup (or adjustments), for Key Click and Error Tone, are supported through the Terminal Emulation Menu screens (if your hand-held is emulation equipped). Refer to the 6400 User’s Guide for detailed descriptions of the Terminal Emulation Menu Screens. NORAND Utilities also provides options for adjusting these parameters. The volume parameter cannot currently be adjusted. To adjust the length and frequency parameters, refer to the following paragraphs.

Using the Terminal Emulation Menu "

"

"

Key Click, can be turned off or on, as desired. The “Key Click” option, in the “Beeper Setup” menu, adjusts the frequency and duration of a sound. Error Tone, option, in the “Beeper Setup” menu, adjusts the frequency and duration of a sound. Internal Beeper, can also be turned off by means of the “Beeper Select option”, in the “Beeper Setup” menu.

Using NORAND Utilities Select the Advanced Functions option, and choose the Set Key Click suboption to adjust the frequency and duration of the sound.

Within an Application Use the Set Key Click Parameters (AX=0402h) API, the Set Error Beep Parameters (AX=0404h) API, and the Beep the Buzzer, AX=0409h, API. " Register BL is the volume adjustment (currently not implemented). " Register pair CX is the adjustment for length, in milliseconds. " Register pair DX is the adjustment for frequency, in Hertz. Use the Get Key Click Parameters, AX=0403h, API and the Get Error Beep Parameters, AX=0405h, API to read the parameter values. Refer to the BIOS Interrupt Support section for further details.

4-32

PEN*KEYR 6400 Programmer’s Reference Guide