Browse
(440) 299-7778
Menu
(440) 299-7778
One-year parts and labor warranty30-day money-back guaranteeEnglishEspañolContact

The text of a manual · part 34 of 35

5250 Terminal Emulation Programmer's Reference Guide: Appendix E: AS/400 Line Generations

Pages 295 to 308 of 318, from 5250 Terminal Emulation Programmer's Reference Guide

The original document is the PDF (1.3 MB). This is its text as extracted, unedited; tables and drawings read best in the PDF, and each page heading opens it at that page.

For the Intermec 6400

Page 295

Appendix E

AS/400 Line Generations "

"

"

"

"

"

"

"

"

"

"

"

"

"

"

"

"

"

"

"

"

"

"

"

"

"

"

"

Overview This appendix contains these examples: "

Multipoint line configuration example

"

5394 description example

"

Device description example

"

Sample configuration for an RC3250 Controller

5250 Terminal Emulation Programmer’s Reference Guide

E-1

Page 296

APPENDIX E

"

AS/400 Line Generations

Multipoint Line Configuration Example The next page shows an example of a multipoint line configuration running an RS-232/V24 interface from the AS/400. " "

"

The left column is the description of the parameter. The “>“ symbol means this value was changed from the default value supplied by IBM. The far right column shows the possible values for the parameter. When the dots continue past the last entry, this means there are more values for this parameter than can fit on the display. To display the remaining values and a short description, place a “?” in the first position of the field and press enter.

The following chart contains helpful comments about some parameters. Parameter Resource name

Comments You need to supply the resource name. The name varies with each system installed.

Data link role

The setting must be *PRI (primary).

Connection type

The type can be *NONSWTPP if you wish. This will limit you to only 16 LUs without changing the line description. There is no advantage to making the line a *NONSWTPP; the AS/400 will allocate the same amount of resources.

NRZI

The setting for NRZI must match the parameter set for the controller. Disabled = *NO and Enabled = *YES. The maximum frame size should be 521. The line description works at the data link level, so this will include the 4 bytes of SDLC information.

Maximum frame size

E-2

5250 Terminal Emulation Programmer’s Reference Guide

Page 297

APPENDIX E

"

AS/400 Line Generations

A similar device description must be provided for each radio terminal. Comments on specific screen lines are in the following chart. Line 3

Description The name following “LIND” uniquely describes the line and enables links to it from “CRTCTLRWS” and “CRTDEVDSP.” Note the same number appearing after “CTLD” in line 16, “LINE” in line 18, and “CTL” in lines 24 and 28.

3

The name following “RSRCNAME” names the physical line.

5

The number following “EXCHID” specifies the device type and serial number for the host computer.

8

“MAXFRAMES” can be “521” or “261,” but must match the number set on the controller.

16

The number following “CTLD” links the controller to the line defined beginning with line 3.

18

The number following “LINE” links the controller to the line defined beginning with line 3.

19

The number following “STNADR” is a number assigned by the programmer.

23

The number following “DEVD” links the device to the controller defined beginning with line 3.

24

The number following “CTL” links the device to the controller defined beginning with line 3.

28

“LOCADR” is the unique local address for the device.

5250 Terminal Emulation Programmer’s Reference Guide

E-3

Page 298

APPENDIX E

"

AS/400 Line Generations

MAIN

AS/400 Main Menu

System:

S1010535

Select one of the following: 1. User tasks 2. Office tasks 3. General system tasks 4. 5. 6. 7. 8. 9.

Files, libraries, and folders Programming Communications Define or change the system Problem handling Display a menu

10. User support and education 11. PC Support tasks 90. Sign off Selection or command ===> crtlinsdlc F3=Exit

F4=Prompt

F9=Retrieve

F12=Cancel

F23=Set initial menu (C) COPYRIGHT IBM CORP. 1980, 1990.

E-4

5250 Terminal Emulation Programmer’s Reference Guide

F13=User support

Page 299

APPENDIX E

"

AS/400 Line Generations

Create Line Desc (SDLC) (CRTLINSDLC) " NOTE:

The line description describes the local system and its link characteristics.

Type choices, press Enter Line description ................... >

RFLINE

Name

Resource Name ...................... >

LIN011

Name

Online at IPL ......................

*YES

*YES, *NO

Data link role ......... ......... >

*PRI

*NEG, *PRI, *SEC

Physical interface ................

*RS232V24 *RS232V24, *V35, *X21, ...

Connection type .................... >

*MP

*NONSWTPP, SWTPP, *MP, SHM, ...

Switched network backup ..........

*NO

*YES, *NO

Exchange identifier ...............

*SYSGEN

05600000-056FFFFF, *SYSGEN

NRZI data encoding ................

*YES

*YES, *NO

Number of attached controllers .. >

4

Line Speed ......................... >

19200

600, 1200, 2400, 4800, ...

Modem type supported ..............

*NORMAL

*NORMAL, *V35, *IBMWRAP ...

Maximum frame size ................

521

265, 521, 1033, 2057

Duplex ..............................

*HALF

*HALF, *FULL

Nonproductive receive timer ......

320

160-4200 (0.1 seconds)

Idle timer .........................

30

5-300 (0.1 seconds)

+ for more values

.. 1-256

More ...

F3=Exit

F4=Prompt

F5=Refresh

F12=Cancel

F13=How to use this display

F24=More keys 5250 Terminal Emulation Programmer’s Reference Guide

E-5

Page 300

APPENDIX E

"

AS/400 Line Generations

5394 Description Example The next page shows an example of a 5394 Control Unit description used on an AS/400. " "

"

The left column is the description of the parameter. The “>“ symbol means this value was changed from the default value supplied by IBM. The far right column shows the possible values for the parameter. When the dots continue past the last entry, this means there are more values for this parameter than can fit on the display. To display the remaining values and a short description, place a “?” in the first position of the field and press enter.

Note that the value for “Attached nonswitched line” is the name of the line description entered on page E-5. The controller type is a 5394, but can also be a 5294. The frame size is the same as on the controller. Also, because the example is connecting to a nonswitched line, the exchange identifier is not required. " NOTE:

E-6

A control unit description is required for each SDLC address.

5250 Terminal Emulation Programmer’s Reference Guide

Page 301

APPENDIX E

MAIN

"

AS/400 Main Menu

AS/400 Line Generations

System:

S1010535

Select one of the following: 1. User tasks 2. Office tasks 3. General system tasks 4. 5. 6. 7. 8. 9.

Files, libraries, and folders Programming Communications Define or change the system Problem handling Display a menu

10. User support and education 11. PC Support tasks 90. Sign off Selection or command ===> crtctlrws F3=Exit

F4=Prompt

F9=Retrieve

F12=Cancel

F13=User support

F23=Set initial menu (C) COPYRIGHT IBM CORP. 1980, 1990.

5250 Terminal Emulation Programmer’s Reference Guide

E-7

Page 302

APPENDIX E

"

AS/400 Line Generations

Create Ctl Desc (Remote WS) (CRTCTLRWS) " NOTE:

The controller description describes the remote system and its link characteristics. One description is required for each SDLC address.

Type choices, and press Enter. Controller description ........ >

RFCTL01

Name

Controller type ................ >

5394

3174, 3274, 5251, 5294 ...

Controller model ............... >

1

0, 1, 0001, 2, 0002, 12, 0012 ...

Link type ....................... >

*SDLC

*IDLC, *LAN, *NONE, *SDLC ...

Online at IPL ...................... *YES

*YES, *NO

Switched connection ............... *NO

*NO, *YES

Switched network backup .......... *NO

*NO, *YES

Attached nonswitched line .... >

RFLINE

Name

Maximum frame size ............ >

517

265-1994, 261, 265, 517 ...

Exchange identifier ............... 00100000-FFFFFFFF Station address .................... 01

01-FE

Text ‘description’ ................ Norand controller address 01 Bottom

F3=Exit

F4=Prompt

F5=Refresh

F13=How to use this display

E-8

F10=Additional parameters F24=More keys

5250 Terminal Emulation Programmer’s Reference Guide

F12=Cancel

Page 303

APPENDIX E

"

AS/400 Line Generations

Device Description Example The next page shows an example of a device description used on the AS/400. " "

"

The left column is the description of the parameter. The “>“ symbol means this value was changed from the default value supplied by IBM. The far right column shows the possible values for the parameter. When the dots continue past the last entry, this means there are more values for this parameter than can fit on the display. To display the remaining values and a short description, place a “?” in the first position of the field and press enter.

This device description would communicate with radio terminal #0 if it was attached to the first address in the RC3250 Controller or RC3240 Controller. This is determined by the “Local location address” field in this device description. The address is in hexadecimal form. The following chart contains helpful comments about some other parameters. Parameter Attached controller

Device type Device model " NOTE:

Comments The “Attached controller” field is the name of the controller that we just created. The device type is always the same for every device. The device model is always the same for every device.

One device description is required for each radio terminal.

5250 Terminal Emulation Programmer’s Reference Guide

E-9

Page 304

APPENDIX E

"

AS/400 Line Generations

MAIN

AS/400 Main Menu

System:

S1010535

Select one of the following: 1. User tasks 2. Office tasks 3. General system tasks 4. 5. 6. 7. 8. 9.

Files, libraries, and folders Programming Communications Define or change the system Problem handling Display a menu

10. User support and education 11. PC Support tasks 90. Sign off Selection or command ===> crtdevdsp F3=Exit

F4=Prompt

F9=Retrieve

F12=Cancel

F23=Set initial menu (C) COPYRIGHT IBM CORP. 1980, 1990.

E-10

5250 Terminal Emulation Programmer’s Reference Guide

F13=User support

Page 305

APPENDIX E

"

AS/400 Line Generations

Create Device Desc (Display) (CRTDEVDSP) Type choices, press Enter. Device description ............. >

RFDEV00

Name

Device class .................... >

*RMT

*LCL, *RMT, *VRT

Device type ..................... >

5291

3101, 3151, 3161, 3162 ...

Device model .................... >

1

0, 1, 2, 4, 11, 12, 23 ...

Local location address ........ >

00

00-FE

Online at IPL ...................

*YES

*YES, *NO

Attached controller ........... >

RFCLT01

Name

Drop line at signoff .......... >

*NO

*YES, *NO

Allow blinking cursor .........

*YES

*YES, *NO

Printer ..........................

Name

Text ‘description’ .............

*BLANK More...

F3=Exit

F4=Prompt

F5=Refresh

F12=Cancel

F13=How to use this display

F24=More keys

5250 Terminal Emulation Programmer’s Reference Guide

E-11

Page 306

APPENDIX E

"

AS/400 Line Generations

MAIN

AS/400 Main Menu

System:

S1010535

Select one of the following: 1. User tasks 2. Office tasks 3. General system tasks 4. 5. 6. 7. 8. 9.

Files, libraries, and folders Programming Communications Define or change the system Problem handling Display a menu

10. User support and education 11. PC Support tasks 90. Sign off Selection or command ===> wrkcfgsts *lin rfline F3=Exit

F4=Prompt

F9=Retrieve

F12=Cancel

F23=Set initial menu (C) COPYRIGHT IBM CORP. 1980, 1990.

E-12

5250 Terminal Emulation Programmer’s Reference Guide

F13=User support

Page 307

APPENDIX E

"

AS/400 Line Generations

Work with Configuration Status System: Position to .

.

.

.

S1010535

Starting characters

Type options, press Enter. 1=Vary on

2=Vary off

5=Work with job

8=Work with description

9=Display mode status . . . Opt

Lin/Ctl/Dev/Mod

Status

1

L15394

VARIED OFF

L15394

-------------Job------------

VARIED OFF

L152910

VARIED OFF

Parameters or command

Bottom

===> F3=Exit

F4=Prompt

F5=Refresh

F12=Cancel

F23=More options

F24=More keys (C) COPYRIGHT IBM CORP. 1980, 1990.

Sample Configuration Following is an example of the matching parameters for an AS/400 5250 configuration with an RC3250 Controller.

5250 Terminal Emulation Programmer’s Reference Guide

E-13

Page 308

APPENDIX E

"

AS/400 Line Generations

Line description . . . . . . . . . . . . . . . . . . . . . . . > RFLINE Resource Name . . . . . . . . . . . . . . . . . . . . . . . > LIN011 Online at IPL . . . . . . . . . . . . . . . . . . . . . . . . .

*YES

Data link role . . . . . . . . . . . . . . . . . . . . . . . . .

*PRI

Physical interface . . . . . . . . . . . . . . . . . . . . .

*RS232V24

Connection type . . . . . . . . . . . . . . . . . . . . . .

*MP

Switched network backup . . . . . . . . . . . . . .

*NO

Exchange identifier . . . . . . . . . . . . . . . . . . . . . . . *SYSGEN NRZI data encoding . . . . . . . . . . . . . . . . . . . . . . *YES Number of attached controllers . . . . . . . . . . > 4

RC3250 Configuration Option

In this case

RS232 or V.35

RS232

Enabled or Disabled . . Enabled SDLC Address . . . . . . . 1-4 possible EXT or 300-38400 . . . . Any speed

Line Speed . . . . . . . . . . . . . . . . . . . . . . . . . . . > 19200 Modem type supported . . . . . . . . . . . . . . . . . . . *NORMAL Maximum frame size . . . . . . . . . . . . . . . . . . . . . 521 Duplex . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . *HALF Nonproductive receive timer . . . . . . . . . . . . . . . 320 Idle timer . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 30

5394 or 5294 . . . . . . . . 5394

Controller description . . . . . . . . . . . . . . . . . . > RFCTL01 Controller type . . . . . . . . . . . . . . . . . . . . . . . > 5394 Controller model . . . . . . . . . . . . . . . . . . . . . . > 1 Link type . . . . . . . . . . . . . . . . . . . . . . . . . . . . > *SDLC Online at IPL . . . . . . . . . . . . . . . . . . . . . . . . . . . . *YES Switched connection . . . . . . . . . . . . . . . . . . . . . . *NO Switched network backup . . . . . . . . . . . . . . . . . *NO Attached nonswitched line . . . . . . . . . . . . . . > RFLINE Maximum frame size . . . . . . . . . . . . . . . . . . > 517 Exchange identifier . . . . . . . . . . . . . . . . . . . .

261 or 517 . . . . . . . . . . 517 SDLC Address . . . . . . . 1-4 possible

Station address . . . . . . . . . . . . . . . . . . . . . . . . . . 01 Device description . . . . . . . . . . . . . . . . . . . . > RFDEV00 Device class . . . . . . . . . . . . . . . . . . . . . . . . . > *RMT Device type . . . . . . . . . . . . . . . . . . . . . . . . . . > 5291 Device model . . . . . . . . . . . . . . . . . . . . . . . . > 1

Radio Terminal Configuration 00-63 . . . . . . . . . . . . . . . 00, 16, 32,

Local location address . . . . . . . . . . . . . . . . . > 00 Online at IPL . . . . . . . . . . . . . . . . . . . . . . . . . . . . *YES Attached controller . . . . . . . . . . . . . . . . . . . . > RFCLT01 Drop line at signoff . . . . . . . . . . . . . . . . . . . . > *NO Allow blinking cursor . . . . . . . . . . . . . . . . . . . . . *YES

E-14

5250 Terminal Emulation Programmer’s Reference Guide or 48