Page 267

Appendix F

System/36 Configuration Guide "

"

"

"

"

"

"

"

"

"

"

"

"

"

"

"

"

"

"

"

"

"

"

"

"

"

"

"

CNFIGSSP----COMMUNICATIONS LINE DEFINITION FOR REMOTE WORK STATIONS THE FOLLOWING LINES HAVE BEEN DEFINED 1. WHICH LINE IS BEING DEFINED . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . (1--10) 2. WHAT TYPE OF LINE IS IT . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1--NONSWITCHED 2--SWITCHED MANUAL CALL 3--SWITCHED AUTOANSWER 4--SWITCHED MANUAL ANSWER 5--X.21 SHORT--HOLD MODE 6-- IBM TOKEN--RING NETWORK 3. AUTOMATIC RECONNECT FOR THE LINE . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Y,N 4. IF LINE IS X.25, ENTER X.25 MEMBER NAME . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

1 1 1

Y

`kcfdppmJobjlqb `lkqoliibo abcfkfqflk EDIT CONTROLLER 1. DESCRIBE THE REMOTE CONTROLLER . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . NORAND SYSTEM 2. CONTROLLER TYPE . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1. 5251 MODEL 12 2. 5294 3.3274 3. CONTROLLER STATION ADDRESS . . . . . . . . . . . . . . . . . . . . . . . . . . . . 01--F0 4. COMMUNICATIONS LINE . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1--10 5. FOR A SWITCHED LINE, OPTIONALLY SPECIFY 1 TO 3 ALTERNATIVE LINES . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

3 01 1

3270 Terminal Emulation Programmer’s Reference Guide F-1

Page 268

APPENDIX F

"

System/36 Configuration Guide

CNFIGSSP -- WORK STATION DEFINITION

REMOTE

SPECIFY THE ARRANGEMENT OF YOUR DISPLAY STATIONS AND PRINTERS. THE POSITIONS CORRESPOND TO THE WORK STATION PORT NUMBER DISPLAYS -50.3277 51.3278 52.3279 PORTS 51 51 51 0--7 ---------8--15 C01 16--23 3274 24--31 ---------DISPLAY STATION COMMUNICATIONS CONFIGURATION LINE 1 HARDWARE CONFIGURATION . . . . . . . . . . . . . . . . . EIA/CCITT LINE TYPE . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . NONSWITCHED MULTIPOINT CONTROL . . . . . . . . . . . . . . . . . . . . . . . N MODEM RATE . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . FULL X.25 DATA LINE . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . N SWITCHED NETWORK BACKUP . . . . . . . . . . . . . . . N

SYSTEM COMMUNICATIONS CONFIGURATION LINE 1 HARDWARE CONFIG . . . . . . . EIA/CITT LINE TYPE . . . . . . . . . . . . . . . . . NONSWITCHED MULTIPOINT CONTROL . . . . N CONTINUOUS CARRIER . . . . Y SDLC RETRY COUNT . . . . . . . 3 SELF TEST REQUIRED . . . . . N

F-2

CLOCK . . . . . . . . . . . . . MODEM NRZI . . . . . . . . . . . . . . . . . . . . N ANSWER TONE. . . . . . N PRI--SDLC TIME OUT . . . . 3.0 MODEM . . . . . . . . . . . . NON--IBM X.25 DATA LINE . . . . . N SEC--SDLC TIME--OUT . . . 10

3270 Terminal Emulation Programmer’s Reference Guide

Page 269

Appendix G

Tandem Configuration Guide "

"

Object:

"

"

"

"

"

"

"

"

"

"

"

"

"

"

"

"

"

"

"

"

"

"

"

"

"

LINE\TTOWN.$SNAXP2

Characterset EBCIDIC Interface RS232 Maxplus 8 Retries 9 Threshold 500 Window 7 Object:

"

Dsrtimeout 4.00 IO pages 2 Noaq OFF Speed 9600 Timeout 2.00 Xmttimeout 1.11

Duplex FULL Luopmsg OFF Pollint 0.25 Station PRIMARY Type (58,0) xpages 256

Flagfill OFF Maxlus 64 Recsize26 Switched OFF Tws OFF

L3timeout 30.00 Puidblk 4095 %7777 Puswtype OFF Servicecount 1

Maxlux 8 %HFFF Recsize 265 Type (13.2)

Allowedmix 0 Luswtype OFF Protocol ITI Type (14,2)

Dbcs NONE Noacq OFF Puname #C121

PU\TTOWN.$SNAXP2.#C121

Address 1 Maxpts 0 Puichum 1048575 Regms OFF Window 7 Object: Address 3 Cryptotype OFF Passthru OFF Recsize 256

L3retry 65535 Noacq OFF %3777777 %HFFFF Actpu COLD

LU\TTOWN.$SNAXP2.#T1211 Characterset EBCIDIC Devtype 3278--2 Actlu COLD Static OFF

3270 Terminal Emulation Programmer’s Reference Guide

G-1

Page 270

APPENDIX G

"

Tandem Configuration Guide

Pathway TCP Parameters for Tandem System TCP TCO--T3270 AUTORESTART 0 CHECK--DIRECTORY ON CODEAREALEN 100000 CPUS 0:1 DEBUG OFF DUMP OFF GUARDIAN--LIB\DEV.$SYSTEM.NEWPWAY.APCITCPL INSPECT ON (FILE\DEV.$SNAXP1.#T9125) MAXPATHWAYS 0 MAXREPLY 2500 MAXSERVERCLASSES 50 MAXSERVER PROCESSES 140 MAXTERMDATA 26000 MAXTERMS 25 NONSTOP 1 PRI 140 PROCESS $DEV2 PROGRAM\DEV.$SYSTEM.NEWPWAY.APCITCP2 SERVERPOOL 13000 STATS ON SWAP\DEV.$DATA TCLPROG\DEV.$DATA.DEVOBJ.PIBM TERMBUF 2000 TERMPOOL 8000

G-2