SECTION 8

"

Controller Commands

Setting x = 0 disables both checks. At x = 1, only CRC-16 is active, and at x = 2 only LRC is active. CRC is cyclic redundancy checking, which uses an algorithm to divide a constant into the numeric binary value of all character bits in a block of data. Quotients are discarded and the remainders are compared. LRC is longitudinal redundancy checking. It uses all character bits to form a check character at both ends of the communication link. These are compared. Host Command

Controller Response

CMT8,x<cr>

OK<cr>

Variables:

x = 0 (disable error checking) x = 1 (enable CRC-16 error checking; disable LRC) x = 2 (enable LRC error checking; disable CRC-16)

Default:

x = 0 (disable error checking)

EXAMPLE 1:

Command: Response:

CMT8,1<cr> OK<cr> The controller checks commands from the host for a two-digit CRC-16 value following <cr>

EXAMPLE 2:

Command: Response:

CMT8<cr> 1<cr> (settings from example 1)

CMT10 Extended Response Mode The CMT10 command is a data checking mechanism which adds a character count to all responses from the controller to the host. For CMT10,1, each string sent to the host is followed by a comma and a decimal character count of the string. For CMT10,2, each string is preceded by a decimal character and a comma. 8-10

3270 Terminal Emulation Programmer’s Reference Guide

Page 139

SECTION 8

"

Controller Commands

Character counts are one greater for CMT10,2 than for CMT10,1 because the CMT10,2 count includes the carriage return at the end of the string and CMT10,1 does not. Host Command

Controller Response

CMT10,x<cr>

OK<cr>

Variables:

x = 0 (disable extended response) x = 1 (enable extended response suffix; comma follows) x = 2 (enable extended response prefix; comma precedescounts up to 1)

Default:

x = 0 (disable extended response)

EXAMPLE 1:

Command: Response:

CMT10,1<cr> OK<cr>

EXAMPLE 2:

Command: Response:

CMT10,2<cr> OK<cr>

EXAMPLE 3:

Command : Response:

CMT10<cr> 0002,2<cr> (assumes setting example 1)

CMT11 Set Dual Base Radio The CMT11 command enables dual UHF base radio operation in the RC3250 Controller. " NOTE:

This command applies to UHF operation only. Controller

Host Command

Controller Response

RC3250 (UHF)

`jqNNIñYÅê[ lhYÅê[

Variables:

x = 0 (single base radio operation only) x = 1 (auxiliary base radio operation only) x = 2 (dual base radio operation)

3270 Terminal Emulation Programmer’s Reference Guide

8-11

Page 140

SECTION 8

"

Controller Commands

Default:

x = 0 (single base radio operation only)

EXAMPLE 1:

Command: Response:

CMT11,1<cr> OK<cr> The controller sends to the auxiliary port only

EXAMPLE 2:

Command: Response:

CMT11<cr> 1<cr> (assumes setting from example 1)

CMT12 Set Dual Speed The CMT12 command enables dual baud rate operation on the RC3250 Controller channels 1 and 2; or, with the MBA3000 Multiple Base Adapter, channels 1, 2, 3, and 4. The variable “x” in the command CMT12,x is the sum of the selected options in the variable list below. The default is x = 0. " NOTE:

8-12

This command applies to UHF operation only. Controller

Host Command

Controller Response

RC3250 (UHF)

CMT12,x<cr>

OK<cr>

Channel

Programmed to

Add

1 (base)

4800 bps or disabled (default) 4800 and 9600 bps 9600 bps only

0 1 2

2 (auxiliary)

4800 bps or disabled (default) 4800 and 9600 bps 9600 bps only

0 4 8

3270 Terminal Emulation Programmer’s Reference Guide

Page 141

SECTION 8

"

Controller Commands

With MBA3000 Multiple Base Adapter Only: Channel

Programmed to

Add

3

4800 bps or disabled (default) 4800 and 9600 bps 9600 bps only

0 16 32

4

4800 bps or disabled (default) 4800 and 9600 bps 9600 bps only

0 64 128

EXAMPLE 1:

Command: Response:

CMT12,137<cr> (choosing 1+8+0+128 = 137) OK<cr> The controller enables channel 1 for dual bps operation, channel 2 for 9600 bps only, disables channel 3, and enables channel 4 for 9600 bps operation

EXAMPLE 2:

Command: Response:

CMT12<cr> 137<cr> (assumes setting from example 1)

CMT13 Automatic Enable The CMT13 command enables all responding wireless stations, only when using RTC protocol. CMT13,0 disables the feature, requiring each wireless station in the network to be enabled by address number. For Automatic Enable use CMT13,1. Host Command

Controller Response

CMT13,x<cr>

OK<cr>

Variables:

x = 0 (disable) x = 1 (enable)

Default:

x = 0 (disable)

3270 Terminal Emulation Programmer’s Reference Guide

8-13

Page 142

SECTION 8

"

Controller Commands

EXAMPLE:

Command: Response:

CMT13,1<cr> OK<cr> The controller enables all responding wireless stations

" NOTE:

When using this option, the host computer does not receive powerup messages from the wireless stations.

CMT15 Remote Base Radio Support The CMT15 command enables ports for base radios and modems. Sixteen settings for “x” enables any combination of 4 pairs of outputs. Channels 3 and 4 require the MBA3000 Multiple Base Adapter. The default is x = 0. " NOTE:

" NOTE:

8-14

This command applies to UHF operation only. Controller

Host Command

Function

Controller Response

RC3250 (UHF)

CMT15,x<cr>

See Table 8-4.

OK<cr>

Both bases for a given pair connected to the MBA3000 Multiple Base Adapter must be either direct connect or remote. They can be mixed between pairs, but not within a single pair.

3270 Terminal Emulation Programmer’s Reference Guide

Page 143

SECTION 8

"

Controller Commands

Table 8-4 Positions for CMT15

EXAMPLE:

x

Base Channel 1

Auxiliary Channel 2

MBA Channel 3

MBA Channel 4

M 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 lcc ON OFF ON OFF ON OFF ON OFF ON OFF ON OFF ON OFF ON

OFF OFF ON ON OFF OFF ON ON OFF OFF ON ON OFF OFF ON ON

OFF OFF OFF OFF ON ON ON ON OFF OFF OFF OFF ON ON ON ON

OFF OFF OFF OFF OFF OFF OFF OFF ON ON ON ON ON ON ON ON

Command: Response:

CMT15,1<cr> OK<cr> enables channel 1 port

CMT16 3270 Data Stream Light Pen Option The CMT16 command controls the light pen bit for scanning. Command CMT16,1<cr> enables the light pen bit in 3270 format to control the scanning function. CMT16,0<cr> disables the light pen function.

3270 Terminal Emulation Programmer’s Reference Guide

8-15

Page 144

SECTION 8

"

Controller Commands

Host Command

Controller Response

CMT16,x<cr>

OK<cr>

Variables:

x = 0 (normal scanner activation; light pen bit does not control scanner) x = 1 (alternate scanner activation; light pen bit controls light pen scanner)

Default:

x = 0 (normal scanner activation; light pen bit does not control scanner)

EXAMPLE 1:

Command: Response:

CMT16,1<cr> OK<cr> (light pen bit controls scanner)

EXAMPLE 2:

Command: Response:

CMT16<cr> 1<cr> (assumes setting from example1)

CMT17 Set 3270 Data Stream Field Delimiter The CMT17 command changes the input field delimiter. The default symbol is the slash, “/” (ASCII decimal number 47). By placing another ASCII decimal number indicator after the comma, the new new ASCII character is designated. The command CMT17,92 replaces the slash “/” with the backslash “ \”.

8-16

Host Command

Controller Response

CMT17,x<cr>

OK<cr>

Variables:

x = two digits representing an ASCII decimal number

Default:

x = 47 (ASCII decimal number for “/”)

3270 Terminal Emulation Programmer’s Reference Guide

Page 145

SECTION 8

"

Controller Commands

EXAMPLE 1:

Command: Response:

CMT17,92<cr> OK<cr> The controller changes the field delimiter character for 3270 data stream operation from “/” (47) to “ \” (92)

EXAMPLE 2:

Command: Response:

CMT17<cr> 92<cr> (assumes setting from example 1)

CMT18 Enable Multiple Base Adapter The CMT18 command enables the MBA3000 Multiple Base Adapter, which expands the controller to eight UHF radio ports in 4 pairs. " NOTE:

This command applies to UHF operation only. Controller

Host Command

Controller Response

RC3250 (UHF)

CMT18,x<cr>

OK<cr>

Variables: Channel 1

Channel 2 x = 0, no ports enabled x = 1, port A enabled x = 2, port B enabled x = 3, A and B enabled x = 0, no ports enabled x = 4, port A enabled x = 8, port B enabled x = 12, A and B enabled

Channel 3

Channel 4 x = 0, no ports enabled x = 16, port A enabled x = 32, port B enabled x = 48, A and B enabled x = 0, no ports enabled x = 64, port A enabled x = 128, port B enabled x = 192, A and B enabled

3270 Terminal Emulation Programmer’s Reference Guide

8-17

Page 146

SECTION 8

"

Controller Commands

Default:

x = 0 (no ports enabled)

EXAMPLE 1:

Command: Response:

CMT18,1<cr> OK<cr> Enables port A, channel 1

EXAMPLE 2:

Command: Response:

CMT18<cr> 1,<cr> (setting from example 1)

CMT20 Set Modem Delay Rate for Multiple Base Adapter The CMT20 command sets a delay compensation time for each of the four pairs of ports on the MBA3000 Multiple Base Adapter. The delay (in milliseconds) may be required to accommodate a modem on a communication line. The “x” parameter, from 0 to 8, sets the delay rate for each pair of ports at 0 to 8 milliseconds. " NOTE:

This command applies to UHF operation only. Controller

Host Command

RC3250 (UHF) CMT20,x1,x2,x3,x4<cr>

EXAMPLE 1:

8-18

Controller Response OK<cr>

Variables:

X1 (pair 1 ) = 0 through 8 X2 (pair 2) = 0 through 8 X3 (pair 3) = 0 through 8 X4 (pair 4) = 0 through 8

Syntax:

CMT20,x1,x2,x3,x4<cr>

Default:

x=0

Command: Response:

CMT20,4,4,4,4<cr> OK<cr> The controller sets all four pairs of ports on MBA3000 Multiple Base Adapter to a 4-millisecond response delay