The text of a manual · part 9 of 10
6210 Hand-Held Computer User's Guide, pages 81 to 90
Pages 81 to 90 of 96
The original document is the PDF (930 KB). This is its text as extracted, unedited; tables and drawings read best in the PDF, and each page heading opens it at that page.
For the Intermec 6210
Page 81
PEN*KEYR Utilities Program
APPENDIX B
"
If you select drop-option OTHER EXTERNAL or OTHER INTERNAL, the Modem Init String pop-up menu appears: MODEM INIT STRING ATE0V0Q0&M0&S1&C1& D2&R/QX0L1 [F2]TEST STRING [YES]OK [NO]QUIT a. Enter the initialization string of the modem you are using. Refer to your modem’s reference manual for information. " NOTE:
Use A and " keys on numeric keyboards to scroll the alphanumeric character set.
" NOTE:
If you leave this menu blank, a string is not saved.
b. Press the [YES] key to enter the string or press [NO] to exit this pop-up menu.
6210 Hand-Held Computer User’s Guide
B-23
Page 82
PEN*KEYR Utilities Program
" NOTE:
APPENDIX B
Testing the modem initialization string is optional.
To test the modem string, do the following: a. Press the [F2] key. The computer replies with “PLEASE WAIT” and tests the string: "
MODEM INIT STRING ATE0V0Q0&M0&S1&C1& D2&R/QX0L1 PLEASE WAIT . . . [F2]TEST STRING [YES]OK [NO]QUIT
Momentarily, the computer displays the modem’s response: MODEM INIT STRING ATE0V0Q0&M0&S1&C1& D2&R/QX0L1 RESULT:
97
[F2]TEST STRING [YES]OK [NO]QUIT
" NOTE:
Zero indicates the modem was successfully configured. Any other value indicates an error. See page B-13 for a list of modem errors. If you purchased this modem from the Norand Mobile Systems Division, contact our Customer Response Center at 1--800--221--9236. If this modem is not from the Norand Mobile Systems Division, contact your modem supplier.
b. Press the [YES] key to update the modem initialization string. The computer returns to the Modem Parameters pop-up menu with OTHER EXTERNAL or OTHER INTERNAL assigned. B-24
6210 Hand-Held Computer User’s Guide
Page 83
PEN*KEYR Utilities Program
APPENDIX B
Suboption 2 PROTOCOL If you select this suboption, a drop-down list of various protocols appears: 1. TTY 2. YMODEM
Press the number of a protocol, or press the Y or B keys to scroll through the list, then press the [YES] key to enter. The computer returns to the Modem Parameters pop-up menu with the selected protocol assigned. Press the [NO] key to exit this drop-down list.
Suboption 3 BPS RATE If you select this suboption, the BPS Rate drop-down list appears with various bits per second (BPS) rates: 1. 2. 3. 4. 5. 6. 7. 8.
1200 2400 4800 9600 19200 38400 57600 115200
Press the number of a BPS rate, or press the Y or B keys to scroll through the list, then press the [YES] key to enter. The computer returns to the Modem Parameters pop-up menu with the selected BPS rate assigned. Press the [NO] key to exit this drop-down list.
6210 Hand-Held Computer User’s Guide
B-25
Page 84
PEN*KEYR Utilities Program
APPENDIX B
Suboption 4 DATA FORMAT If you select this suboption, the Data Format drop-down list appears: 1. 8N1 2. 7E1
Press the number of a data format, or press the Y or B keys to scroll through the list, then press the [YES] key to enter. The computer returns to the Modem Parameters pop-up menu with the selected data format assigned. Press the [NO] key to exit this drop-down list.
Suboption 5 AUTO ANSWER This suboption is not supported at this time.
Option 5 NETWORK INTERFACE Network Interface appears as Option 5 when Option 2. COMM SETTINGS is set to NRINET, TFTP, or NOVELL NETWARE. If you select this option, the Network Interface drop-down list appears: 1. ETHERNET 2. RS485
Press the number of a network interface, or press the Y or B keys to scroll through the list, then press the [YES] key to enter. The computer returns to the Communications menu with the selected network interface assigned.
B-26
6210 Hand-Held Computer User’s Guide
Page 85
PEN*KEYR Utilities Program
APPENDIX B
Option 5 PHONE NUMBER Phone Number appears as Option 5 when Option 2. COMM SETTINGS is set to MODEM/DIRECT. If you select this option, the Phone Number pop-up menu appears: PHONE NUMBER 9...13193693282 [ . ]DIALING PAUSE [YES]OK [NO]QUIT
Enter up to 16 characters. Use the [¬SP] key to backspace; use the [CLR] to reset to the previous phone number, and press [.] to insert a dialing pause command (“,”). Press the [YES] key to save the new phone number and return to the Communications Settings menu. Press the [NO] key to exit this pop-up menu.
6210 Hand-Held Computer User’s Guide
B-27
Page 86
PEN*KEYR Utilities Program
APPENDIX B
Option 9 ADVANCED UTILITIES If you select this option, the Advanced Utilities menu appears: PEN*KEY UTILITIES ADVANCED UTILITIES 1. 2. 3. 4. 5.
SET DATE/TIME BATTERY STATUS FORMAT RAM DRIVE FORMAT RAM CARD SET BOOT DRIVE
Press the number of an advanced utility option, or press the Y or B keys to scroll through the list, then press the [YES] key to enter. " NOTE:
B-28
Suboption 4 FORMAT RAM CARD appears only if the FORMAT.COM program is in the PATH. The 6200 512 KB flash does not contain FORMAT.COM.
6210 Hand-Held Computer User’s Guide
Page 87
PEN*KEYR Utilities Program
APPENDIX B
Suboption 1 SET DATE/TIME If you select this suboption, the Set Date/Time pop-up menu appears: SET DATE/TIME DATE: TIME:
01/20/80 23:12:04 [NO]QUIT
Enter numbers for the month, day, year (1980--2079), hour, minute, and second (up to 23:59:59). Press the [YES] key after each entry. An incorrect entry causes the computer to default to the initial number. Press the [NO] key to exit this pop-up menu.
Suboption 2 BATTERY STATUS Use this suboption to check battery status, and for 6210 Computers, to condition these batteries. The Battery Status screen appears when you select this suboption: PEN*KEY UTILITIES BATTERY STATUS MAIN PACK VOLTAGE LAST COND CAPACITY
CHARGING 7.37 10/10/96 23:59
BACKUP VOLTAGE LAST COND CAPACITY
2.94 10/10/96 23:59
CHARGER
16.22
[F2]CONDITION BATT [NO]QUIT 6210 Hand-Held Computer User’s Guide
B-29
Page 88
PEN*KEYR Utilities Program
APPENDIX B
MAIN PACK: " “OK” " “LOW”
Status of the main battery pack: Battery operating properly. Power running low, needs recharging. " “CRITICAL” Power dangerously low, recharge soon or lose all data. " “CHARGING” Main battery pack recharging. " “MISSING” Main battery pack not loaded or detected. " VOLTAGE: Amount of operational battery voltage. " LAST COND: Date when battery was last conditioned. “??/??/??” if unknown. " CAPACITY: Estimated time battery is operational after complete charge. “??:??” if unknown. " CHARGER: Amount of voltage supplied by external charge source. To start a conditioning cycle for the 6210 Computer main battery pack or backup battery, press [F2] to access this list: "
1. MAIN PACK 2. BACKUP [NO]QUIT
" NOTE:
B-30
Batteries can be conditioned only on 6210 Computers. The 6200 Computer cannot condition batteries.
6210 Hand-Held Computer User’s Guide
Page 89
PEN*KEYR Utilities Program
APPENDIX B
Select option 1. MAIN PACK to condition the main battery pack; or select option 2. BACKUP to condition the backup battery. The Battery Conditioning screen appears with the status of the battery selected: PEN*KEY UTILITIES BATTERY CONDITIONING MAIN PACK VOLTAGE DISCHARGING NO ERRORS
"
9.99 23:59
DISCHARGING: The displayed time is the elapsed time in the current conditioning state, not the total conditioning time. Elapsed time is tracked only until conditioning is complete or has failed. The following conditioning states may be displayed: " “INITIALIZING” System is initializing " “DISCHARGING” Battery is discharging " “CHARGING” Battery is charging " “COMPLETE” Battery conditioning complete " “FAILED” Battery conditioning failed
6210 Hand-Held Computer User’s Guide
B-31
Page 90
PEN*KEYR Utilities Program
"
" NOTE:
APPENDIX B
NO ERRORS The status of the battery conditioning cycle. If the battery conditioning fails, one of the following messages appears: " “OLD POWER SUPPLY NOT SUPPORTED” " “CANNOT CONDITION BOTH MAIN AND BKUP” " “CHARGE LOST DURING CONDITION CYCLE” " “CHARGE NOT ENABLED” " “TEMPERATURE TOO HOT OR COLD” " “POWER FAILURE” " “SYSTEM SUSPENDED” " “NO BATTERY” " “INIT FAILED NOT SUPPORTED” " “ERROR #NNN” Unknown error code nnn occurred.
[YES] CONTINUE does not appear until the conditioning cycle is complete. Menu Option 1 MAIN PACK
" NOTE:
The main battery pack conditioning cycle takes up to 12 hours to complete.
A condition cycle cannot be stopped by any means except when the charge is removed or when there is a power failure.
B-32
6210 Hand-Held Computer User’s Guide