For the Intermec 5020

Page 134

Chapter 4, Using the Terminal Emulation Menus

2) Barcode Parms (2415, 2425, 2435A, 2455, 2475, 248X, 5020, 700 Series) The 2) Barcode Parms (parameters) menus designate whether you are using a bar code scanner and scan options. Barcode Parms 1) Code 39 Encoded 2) 3) Concatenate 4) RS232 Stream 5) Stream Scan 6) Scan All Flds

4) RS232 Stream is blank for 5020, 700 Series

1) Code 39 Encoded By default, 1) Code39 Encoded is disabled. When you enable this option, the key press sequences for Encoded Code 39 are used. For more information, see Appendix A, “Bar Code Scanning.”

3) Concatenate Each bar code read is added to the end of the previous bar code read until the 2415, 2425, 2435A, 2455, 2475, 248X, 5020, or 700 Series terminal meets a condition forcing transmission to the host. When this option is OFF, each bar code read is placed at the beginning of the current input field. After a bar code is placed in a field, any subsequent read replaces the first read. Note: If you access the TE configuration menus when 4) RS232 Stream is enabled, all RS-232 data received during this time is lost. Only the data arriving from the COM1 port on the hand-held terminal is received.

4) RS232 Stream (blank for 5020, 700 Series) If this option is enabled, the terminal watches the RS-232 port for activity in which the terminal reads in the RS-232 data and sends it to the host. This enables support for fixed-station scanners or scales that send only RS-232 data without having the host send an extended command to enable the RS-232 port. Default for 4) RS232 Stream is disabled. For information about setting scanner options when this is enabled, see Chapter 2, “Using Terminal Emulation Applications.”

5) Stream Scan If the scanned bar code is too big for the input field, the overflow information appears in the next field and continues until the entire bar code is entered. When this option is OFF, and the scanned bar code is too big for the input field, the overflow information is dropped.

6) Scan All Flds (Fields) When this option is selected, the scanner is enabled when the cursor is in an input field. When this option is OFF, the host computer must enable the scanner for each input field that requires scanned data. TE 2000 VT/ANSI Terminal Emulation Programmer’s Guide

109

Page 135

Chapter 4, Using the Terminal Emulation Menus

2) Barcode Parms (6400, 5055, 59XX, 17XX, 11XX) The 2) Barcode Parms (parameters) menus designate: S If you are using a bar code scanner S Scan options S The bar code symbologies to use (the terminal can only decode the enabled bar code symbologies) S Options for each enabled bar code symbology, such as the minimum and maximum bar code lengths

1) Scanner Type Use the 1) Scanner Type menu to designate the type of bar code scanner. To make a selection, press the numeric key corresponding to the desired option, then press [Enter] to access the 2) Scan Options menu. Scanner Type 1) No Scanner 2) Wand 3) Laser 4) Wand Emulate 5) Auto Detect

2) Wand, 4) Wand Emulate, and 5) Auto Detect are for 59XX, 17XX, 11XX

Note: If 1) No Scanner is chosen, the remaining scanner and bar code options can be set. Then, if a scanner is used at a later time, only the scanner type needs to be designated. Selected options are highlighted on the display. Press a key corresponding to that option to deselect a selected option.

110

TE 2000 VT/ANSI Terminal Emulation Programmer’s Guide

Page 136

Chapter 4, Using the Terminal Emulation Menus

2) Scan Options Use the 2) Scan Options menu to designate how the terminal handles scanned bar codes. Press [Enter] to advance to additional 2) Scan Options menus. Scan Options 1) Redundancy 2) MOD 10 Check 3) Concatenate 4) BC Type Char 5) Stream Scan 6) Scan All Flds 7) More

1) Redundancy and 4) BC Type Char are for 6400, 59XX, 17XX, 11XX

S 1) Redundancy (6400, 59XX, 17XX, 11XX) This option requires two identical scans of a bar code, one right after another, before the terminal accepts the scan as valid. S 2) Mod 10 Check When you select this option, a check digit is added at the end of the bar code after a good read. This is a variation of the modulus 10 formula and is used infrequently. Mod 10 checks the validity of a bar code number, to ensure the number is within a set of numbers valid for its symbology. “Mod” is the remainder of a division of two numbers. The bar code number is divided by 10, until the number (or modulus) is less than 10. If the modulus subtracted from 10 (remainder) is equal to zero, then the bar code number is valid. S 3) Concatenate Each bar code read is added to the end of the previous bar code read until the 6400 Computer or 5055 PC meets a condition forcing transmission to the host. When this option is OFF, each bar code read is placed at the beginning of the current input field. After a bar code is placed in a field, any subsequent read replaces the first read. S 4) BC Type Char (6400, 59XX, 17XX, 11XX) This option adds a character associated with the bar code type at the beginning of the scanned bar code. S 5) Stream Scan If the scanned bar code is too big for the input field, the overflow information appears in the next field and continues until the entire bar code is entered. When this option is OFF, and the scanned bar code is too big for the input field, the overflow information is dropped. S 6) Scan All Flds (Fields) When this option is selected, the scanner is enabled when the cursor is in an input field. When this option is OFF, the host computer must enable the scanner for each input field that requires scanned data. TE 2000 VT/ANSI Terminal Emulation Programmer’s Guide

111

Page 137

Chapter 4, Using the Terminal Emulation Menus

S 7) More This brings you additional scanning options that adjust scanning timeout and characters sent before and after the scanned data. S 1) Scan Timeout (59XX, 17XX, 11XX) Use this option to adjust the scanning timeout period from 1 to 200 seconds. When using a proximity-detect scanner, you can shorten the timeout period to speed up scanning while also reducing the duration of errant scans. With a long-range scanner, you may want to increase the timeout period to ensure sufficient aiming time. Scan Timeout Seconds XXX

S 2) Scan PreChar and 3) Scan PostChar Enter a hexadecimal value from 00–FF for the character to be sent preceding the scanned data or after the scanned data. The value of 20h means that pre- or post-characters are not sent. Scan Options 1) Scan Timeout 2) Scan PreChar 3) Scan PostChar

112

1) Scan Timeout is for 59XX, 17XX, 11XX

TE 2000 VT/ANSI Terminal Emulation Programmer’s Guide

Page 138

Chapter 4, Using the Terminal Emulation Menus

Scan Options to Enable Bar Codes There are menus of options to enable (or disable) various bar code symbologies. To enable a bar code, press the numeric key corresponding to the number of the bar code symbology (shown on menu), then press [Enter]. After enabling a particular bar code, options may have to be selected for the bar code. After selecting the desired options, set the length requirements (such as minimum and maximum length, fixed lengths, leading and trailing character options, etc.). Once the length requirements are set, the terminal returns to the same 2) Scan Options menu. Choose another bar code symbology from that menu or press [Enter] to advance to the next Scan Options menu. Scan Options 1) UPC 2) EAN 3) Code 39 4) Code 128 5) Codabar

4) Sys 1 UPCE is for 6400, 17XX, 11XX

6) Relax Std is for 59XX, 17XX, 11XX

UPC 1) Enabled 2) Add-On 2 3) Add-On 5 4) Sys 1 UPCE 5) Sys 0 UPCE 6) Expand E To A

Code 39 1) Enabled 2) Chk Digit 3) Extended 4) Encoded 5) Auto-Encoded 6) Relax Std 7) Full ASCII

[1]

[3]

[2]

[4]

EAN 1) Enabled 2) Add-On 2 3) Add-On 5 4) Expand 8 To 13

Code 128 1) Enabled 2) UCC/EAN 3) No UCC Type 4) UCC F1 Value

[6] RELAX CODE 39 1) Quiet zone 2) Data Decode 3) Element Decode 4) START Decode

[5]

TE 2000 VT/ANSI Terminal Emulation Programmer’s Guide

Codabar 1) Codabar 2) ABC Codabar

2) ABC Codabar is for 59XX, 17XX, 11XX

113

Page 139

Chapter 4, Using the Terminal Emulation Menus

Scan Options of Additional Bar Codes This menu offers additional bar code selections. After enabling a bar code symbology, various options, including length can be set. When all options are set, the display returns to the 2) Scan Options menu. This menu and the bar code symbologies to be enabled are shown below. When all needed bar code symbologies are enabled, press [Enter] to return to the first 1) Scan Options menu. Press [Enter] again to back out and return to the 1) Set-up Parms menu.

5) Code 11 is for 59XX, 17XX, 11XX

Plessey 1) Enabled 2) MOD10 Chk 3) MOD11 Chk

Int 2 of 5 1) Enabled 2) Chk Digit

Code 11 1) Enabled 2) Chk Dig 1 3) Chk Dig 2

114

Scan Options 2 1) Plessey 2) Str 2 of 5 3) Int 2 of 5 4) CI 2 of 5 5) Code 11 6) Code 93

[1]

[3]

[5]

[2]

Str 2 of 5 1) Enabled 2) Disabled

[4]

CI 2 of 5 1) Enabled 2) Disabled

[6]

Code 93 1) Enabled 2) Disabled

TE 2000 VT/ANSI Terminal Emulation Programmer’s Guide

Page 140

Chapter 4, Using the Terminal Emulation Menus

Lengths Options The Lengths Options menus determine the maximum and minimum length for a specific bar code symbology. Setting the length of enabled bar codes helps the terminal determine if a scanned bar code is valid and improves response time. The length options must be set for each enabled bar code. 1 Key in the maximum length (0–99), then press [Enter]. 2 Key in the minimum length (0–99), then press [Enter]. 3 Fixed-length entries override the maximum and minimum length entries (minimum and maximum are used for chosen codes). If fixed lengths are not needed for the enabled bar code, enter zero (0). Enter the fixed length (0–99), then press [Enter]. Up to four prompts to set another fixed length will appear. Enter zero (0) for the unused fixed lengths. Note that I 2 of 5 only supports fixed lengths 1 and 2. Entries in 3 and 4 are ignored. 4 Enter the number of characters (0–15) to drop from the front (leading) edge of the scanned bar code, then press [Enter]. 5 Enter the number of characters (0–15) to drop from the rear (trailing) edge of the scanned bar code, then press [Enter].

TE 2000 VT/ANSI Terminal Emulation Programmer’s Guide

115

Page 141

Chapter 4, Using the Terminal Emulation Menus

After all of the length options are set for the enabled bar code, the display returns to one of the 1) Scan Options menus (depending on which menu the bar code was enabled).

(bar code type) Max Length xx

(bar code type) Max Length xx Min Length xx Fix Length 1 xx Fix Length 2 xx Fix Length 3 xx

(bar code type) Max Length xx Min Length xx

(bar code type) Max Length xx Min Length xx Fix Length 1 xx Fix Length 2 xx Fix Length 3 xx Fix Length 4 xx

(bar code type) Max Length xx Min Length xx Fix Length 1 xx

(bar code type) Drop Leading xx

(bar code type) Max Length xx Min Length xx Fix Length 1 xx Fix Length 2 xx

(bar code type) Drop Leading xx Drop Trailing xx

3) Protocol Opts Use the 3) Protocol Opts menu to designate the type of terminal emulation the host supports. You can also use it to designate additional commands and command sets. Protocol Opts 1) Host View Sze 2) Data Stream 3) Extended Cmds 4) 5250 5) 3270 6) VT/ANSI 7) Native

116

7) Native is blank if UDP Plus or TCP/IP

TE 2000 VT/ANSI Terminal Emulation Programmer’s Guide

Page 142

Chapter 4, Using the Terminal Emulation Menus

1) Host View Sze The 1) Host View Sze option tells the terminal the format of display information sent from the host. The display viewing size equals 1920 (the number of rows times the number of columns). The exception is with 5250 Terminal Emulation which has an additional row for error messages and therefore has 2000 characters. The default setting for Native Terminal Emulation is 120 columns by 16 rows (equals 1920). The default for VT/ANSI Terminal Emulation is 80 columns by 24 rows (equals 1920). The default for 5250 Terminal Emulation is 80 columns by 24 rows (25 with error messages). The default for 3270 Terminal Emulation depends on what the original setting was before changing to the 3270 Terminal Emulation. Remember that the total characters must equal 1920 (number of rows by the number of columns) unless using 5250 Terminal Emulation with error messages. Enter a number between 1–80 to change the width. Press [Enter] to return to the 3) Protocol Opts menu. “xx” is the width.

Host View Sze Width xx

2) Data Stream Enter the number corresponding to the type of host computer to specify the data stream used. Press [Enter] to return to the 3) Protocol Opts menu. Data Stream 1) Native 2) 3270 3) 5250 4) VT/ANSI

1) Native is blank if UDP Plus or TCP/IP

Note: For 2415, 2425, 2435A, 2455, 2475, 248X, 5020, and 700 Series, you can also set the emulation type through the 1) ITC Server or 3) Direct Connect options.

TE 2000 VT/ANSI Terminal Emulation Programmer’s Guide

117

Page 143

Chapter 4, Using the Terminal Emulation Menus

For information about 3270, 5250, or Native TE, see these manuals: S TE 2000 3270 Terminal Emulation Programmer’s Guide (P/N 977-055-003) S TE 2000 5250 Terminal Emulation Programmer’s Guide (P/N 977-055-004) S Native Terminal Emulation Programmer’s Guide (P/N: 977-055-006)

3) Extended Cmds (Commands) Use 3) Extended Cmds to enable or disable extended commands. By default, extended commands are disabled. For more information about extended commands, see Chapter 7, “Extended Commands.” When this option is enabled, the host computer can change or use RS-232 communications (such as printers), bar code options, display screen and font size, and error tone features of the unit. Press [1] to enable or press [2] to disable the extended command list. Press [Enter] to return to the 3) Protocol Opts menu. Extended Cmds 1) Enabled 2) Disabled

4) 5250 (Options) The 4) 5250 menu enables the following features if the 5250 communication protocol is used. Press the appropriate number to enable an option, then press [Enter] to return to the 3) Protocol Opts menu. S 1) Beep On Error Causes the buzzer to emit when an error condition occurs; does not lock up the keyboard. S 2) Auto Tab Scan Causes the cursor to automatically tab forward to the next input field when a good scan is obtained. S 3) Telnet (blank for 5020, 700 Series) Handles the telnet option negotiations to establish a session with an appropriate telnet server. Note: 3) Telnet is not changeable if TCP/IP is used. S 4) Device Name Enters a physical name for the device. This name is 1–10 characters with allowable values of A–Z, a–z, 0–9, and #, $, -, and @. 5250E RFC 1572 Support. Note: The first character of 4) Device Name cannot start with a number (0–9).

118